Yun Gyong Ahn
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yun Gyong Ahn has a total of 144 co-authors. Here are the top co-authors by number of shared publications:
Jeoung Hwa Shin
Seoul Center, Korea Basic Science Institute, Seoul, 02841, South Korea
12 shared publications- Ji Yi Lee
Department of Environmental Science and Engineering Ewha Womans University Seoul Republic of Korea
9 shared publications Ji Yi Lee
7 shared publicationsYong Pyo Kim
7 shared publicationsNa Rae Choi
6 shared publicationsGeum-Sook Hwang
Western Seoul Center, Korea Basic Science Institute, Seoul 03759, Republic of Korea
5 shared publications
Latest Publications
- Open Access
Probabilistic Ecological Risk Assessment of Synthetic Musk Compounds in the Han River Estuary: Integrating Multi-Year Monitoring and Explainable Machine Learning
Synthetic musk compounds (SMCs) are emerging contaminants frequently detected in aquatic environments due to their widespread use in personal care and household products. This study investigated the occurrence, environmental drivers, and ecological risks of twelve SMCs in the Han River estuary and adjacent coastal waters, Korea, using three years of monitoring data (2020–2022). A total of 222 water samples from 13 monitoring stations were analyzed by GC–MS. 1,3,4,6,7,8-hexahydro-4,6,6,7,8,8-hexamethylcyclopenta-(g)-2-benzopyran (HHCB) was the dominant compound, followed by musk ketone (MK). Total SMC concentrations ranged from non-detectable levels to 157.6 μg/L, with the highest concentrations consistently observed at wastewater treatment facilities. XGBoost-SHAP analysis identified total nitrogen (TN) as the most influential predictor of SMC occurrence. This association reflects the shared wastewater origin of the two rather than any causal link, so that TN serves as an indicator of wastewater influence rather than of SMC concentration itself. Ecological risks were evaluated using Monte Carlo-based probabilistic hazard quotient (HQ) analysis. HHCB and MK exhibited the highest risks, with mean HQ values exceeding 1.0 at wastewater treatment facilities, indicating potential ecological concern. In contrast, most coastal sites showed low risk levels. The observed spatial patterns identified wastewater discharge zones as major hotspots of SMC exposure and ecological risk. These findings highlight the importance of wastewater-derived SMCs as emerging contaminants in estuarine environments and demonstrate the utility of integrating long-term monitoring, explainable machine learning, and probabilistic risk assessment for ecological risk characterization.
Open AccessProbabilistic Ecological Risk Assessment of Synthetic Musk Compounds in the Han River Estuary: Integrating Multi-Year Monitoring and Explainable Machine Learning
Synthetic musk compounds (SMCs) are emerging contaminants frequently detected in aquatic environments due to their widespread use in personal care and household products. This study investigated the occurrence, environmental drivers, and ecological risks of twelve SMCs in the Han River estuary and adjacent coastal waters, Korea, using three years of monitoring data (2020–2022). A total of 222 water samples from 13 monitoring stations were analyzed by GC–MS. 1,3,4,6,7,8-hexahydro-4,6,6,7,8,8-hexamethylcyclopenta-(g)-2-benzopyran (HHCB) was the dominant compound, followed by musk ketone (MK). Total SMC concentrations ranged from non-detectable levels to 157.6 μg/L, with the highest concentrations consistently observed at wastewater treatment facilities. XGBoost-SHAP analysis identified total nitrogen (TN) as the most influential predictor of SMC occurrence. This association reflects the shared wastewater origin of the two rather than any causal link, so that TN serves as an indicator of wastewater influence rather than of SMC concentration itself. Ecological risks were evaluated using Monte Carlo-based probabilistic hazard quotient (HQ) analysis. HHCB and MK exhibited the highest risks, with mean HQ values exceeding 1.0 at wastewater treatment facilities, indicating potential ecological concern. In contrast, most coastal sites showed low risk levels. The observed spatial patterns identified wastewater discharge zones as major hotspots of SMC exposure and ecological risk. These findings highlight the importance of wastewater-derived SMCs as emerging contaminants in estuarine environments and demonstrate the utility of integrating long-term monitoring, explainable machine learning, and probabilistic risk assessment for ecological risk characterization.
- Open Access
- 17 April 2026
- Published by Elsevier in Ultrasonics Sonochemistry
- Vol. 129, 107862
Sonochemical hydrogen production in a 300 kHz sonoreactor: Comparative effects of short‑chain carboxylic acids, pH, and dissolved gas
- 17 April 2026
- Published by Elsevier in Ultrasonics Sonochemistry
- Vol. 129, 107862
Open AccessSonochemical hydrogen production in a 300 kHz sonoreactor: Comparative effects of short‑chain carboxylic acids, pH, and dissolved gas
- Open Access
- 7 August 2025
- Published by MDPI AG in Chemosensors
- Vol. 13 (8) , 292
Comparison of Two Derivative Methods for the Quantification of Amino Acids in PM2.5 Using GC-MS/MS
Amino acids (AAs), a type of nitrogen-based organic compounds in the atmosphere, are directly and indirectly related to climate change, and as their link to allergic diseases becomes more known, the need for quantitative analysis of ultrafine dust (PM2.5) will become increasingly necessary. When sensing water-soluble AAs using a gas chromatograph combined with a tandem mass spectrometer (GC-MS/MS), derivatization should be considered to increase the volatility and sensitivity of target analytes. In this study, two methods were used to compare and evaluate 13 AA derivatives in PM2.5 samples: N-tert-butyldimethylsilyl-N-methyltrifluoroacetamide with 1% tert-butyldimethylchlorosilane (MTBSTFA w/1% t-BDMCS), which is preferred for silylation, and ethyl chloroformate (ECF) with methanol (MeOH) for chloroformate derivatization. The most appropriate reaction conditions for these two derivative methods, such as temperature and time, and the analytical conditions of GC-MS/MS for the qualitative and quantitative analysis of AAs were optimized. Furthermore, the calibration curve, detection limit, and recovery of both methods for validating the quantification were determined. The two derivative methods were applied to 23 actual PM2.5 samples to detect and quantify target AAs. The statistical significances between pairwise measurements of individual AAs detected by both methods were evaluated. This study will help in selecting and utilizing appropriate derivative methods for the quantification of individual AAs in PM2.5 samples.
- 7 August 2025
- Published by MDPI AG in Chemosensors
- Vol. 13 (8) , 292
Open AccessComparison of Two Derivative Methods for the Quantification of Amino Acids in PM2.5 Using GC-MS/MS
Amino acids (AAs), a type of nitrogen-based organic compounds in the atmosphere, are directly and indirectly related to climate change, and as their link to allergic diseases becomes more known, the need for quantitative analysis of ultrafine dust (PM2.5) will become increasingly necessary. When sensing water-soluble AAs using a gas chromatograph combined with a tandem mass spectrometer (GC-MS/MS), derivatization should be considered to increase the volatility and sensitivity of target analytes. In this study, two methods were used to compare and evaluate 13 AA derivatives in PM2.5 samples: N-tert-butyldimethylsilyl-N-methyltrifluoroacetamide with 1% tert-butyldimethylchlorosilane (MTBSTFA w/1% t-BDMCS), which is preferred for silylation, and ethyl chloroformate (ECF) with methanol (MeOH) for chloroformate derivatization. The most appropriate reaction conditions for these two derivative methods, such as temperature and time, and the analytical conditions of GC-MS/MS for the qualitative and quantitative analysis of AAs were optimized. Furthermore, the calibration curve, detection limit, and recovery of both methods for validating the quantification were determined. The two derivative methods were applied to 23 actual PM2.5 samples to detect and quantify target AAs. The statistical significances between pairwise measurements of individual AAs detected by both methods were evaluated. This study will help in selecting and utilizing appropriate derivative methods for the quantification of individual AAs in PM2.5 samples.
- 19 May 2025
- Published by Elsevier in Atmospheric Environment
- Vol. 356
Trend and health risk of carcinogenic particulate nitrosamines in the atmosphere in Seoul, South Korea
- 19 May 2025
- Published by Elsevier in Atmospheric Environment
- Vol. 356
Trend and health risk of carcinogenic particulate nitrosamines in the atmosphere in Seoul, South Korea
- 9 May 2025
- Published by Elsevier in Atmospheric Environment
- Vol. 356
Spatial characteristics of nitro- and oxy-PAHs during winter in Northeast Asia
- 9 May 2025
- Published by Elsevier in Atmospheric Environment
- Vol. 356
Spatial characteristics of nitro- and oxy-PAHs during winter in Northeast Asia
- Open Access
Comparison of Sample Preparation and Detection Methods for the Quantification of Synthetic Musk Compounds (SMCs) in Carp Fish Samples
This study deals with the separation and detection methods for 12 synthetic musk compounds (SMCs), which are some of the emerging contaminants in fish samples, are widely present in environmental media, and can be considered serious risks due to their harmful effects. For the separation of co-extracted substances and the target SMCs in fish samples after ultrasonic extraction, four solid-phase extraction (SPE) sorbents were investigated. The recoveries of SMCs from 10 mL of eluent, as optimized by the elution profile, were within the acceptable range of 80–120% in all SPE types, and it was found that nitro musk and polycyclic musk compounds were separated more clearly in Florisil SPE than others (Aminopropyl, Alumina-N, PSA). Furthermore, the results of measuring the matrix effects by each SPE through the spiking experiments showed that Florisil SPE was superior. The comparison of a gas chromatograph-single quadrupole mass spectrometer (GC-SQ/MS) with selected ion monitoring (SIM) mode and GC-triple quadrupole mass spectrometer (GC-QqQ-MS/MS) with multiple reaction monitoring (MRM) modes regarding the detection method of SMCs showed that the method detection limits (MDLs) of SMCs were on average ten times lower when GC-QqQ-MS/MS with MRM mode was used. The differences between the two methods can provide essential information for selecting an analytical method in related research fields that require appropriate detection levels, such as risk assessment or pollution control.
Open AccessComparison of Sample Preparation and Detection Methods for the Quantification of Synthetic Musk Compounds (SMCs) in Carp Fish Samples
This study deals with the separation and detection methods for 12 synthetic musk compounds (SMCs), which are some of the emerging contaminants in fish samples, are widely present in environmental media, and can be considered serious risks due to their harmful effects. For the separation of co-extracted substances and the target SMCs in fish samples after ultrasonic extraction, four solid-phase extraction (SPE) sorbents were investigated. The recoveries of SMCs from 10 mL of eluent, as optimized by the elution profile, were within the acceptable range of 80–120% in all SPE types, and it was found that nitro musk and polycyclic musk compounds were separated more clearly in Florisil SPE than others (Aminopropyl, Alumina-N, PSA). Furthermore, the results of measuring the matrix effects by each SPE through the spiking experiments showed that Florisil SPE was superior. The comparison of a gas chromatograph-single quadrupole mass spectrometer (GC-SQ/MS) with selected ion monitoring (SIM) mode and GC-triple quadrupole mass spectrometer (GC-QqQ-MS/MS) with multiple reaction monitoring (MRM) modes regarding the detection method of SMCs showed that the method detection limits (MDLs) of SMCs were on average ten times lower when GC-QqQ-MS/MS with MRM mode was used. The differences between the two methods can provide essential information for selecting an analytical method in related research fields that require appropriate detection levels, such as risk assessment or pollution control.
- Open Access
- 8 July 2024
- Published by Elsevier in Chemosphere
- Vol. 363, 142806
Statistical comparison for assessing agreement between two mass spectrometric methods for the analysis of polychlorinated dibenzo-p-dioxins and furans (PCDDs/Fs) in contaminated soils
- 8 July 2024
- Published by Elsevier in Chemosphere
- Vol. 363, 142806
Open AccessStatistical comparison for assessing agreement between two mass spectrometric methods for the analysis of polychlorinated dibenzo-p-dioxins and furans (PCDDs/Fs) in contaminated soils
- Open Access
Developing an Improved Strategy for the Analysis of Polychlorinated Dibenzo-p-Dioxins/Furans and Dioxin-like Polychlorinated Biphenyls in Contaminated Soils Using a Combination of a One-Step Cleanup Method and Gas Chromatography with Triple Quadrupole Mass Spectrometry
Soils contaminated with polychlorodibenzo-p-dioxins (PCDDs), polychlorodibenzofurans (PCDFs), and dioxin-like (dl) polychlorinated biphenyls (PCBs), known as persistent organic pollutants (POPs), have garnered global attention because of their toxicity and persistence in the environment. The standard method for target analytes has been used; however, it is an obstacle in large-scale sample analysis due to the comprehensive sample preparation and high-cost instrumental analysis. Thus, analytical development of inexpensive methods with lower barriers to determine PCDDs/Fs and dl-PCBs in soil is needed. In this study, a one-step cleanup method was developed and validated by combining a multilayer silica gel column and Florisil micro-column followed by gas chromatography with triple quadrupole mass spectrometry (GC-QqQ-MS/MS). To optimize the separation and quantification of 17 PCDDs/Fs and 12 dl-PCBs in soils, the sample cleanup and instrumental conditions were investigated. For quantification method validation, spiking experiments were conducted to determine the linearity of the calibration, recovery, and method detection limit of PCDDs/Fs and dl-PCBs using isotopic dilution GC-QqQ-MS/MS. The applicability of the simultaneous determination of PCDDs/Fs and dl-PCBs was confirmed by the recovery of native target congeners and labeled surrogate congeners spiked into the quality-control and actual soil samples. The results were in good agreement with the requirements imposed by standard methods. The findings in this work demonstrated the high accessibility of the sample cleanup and analysis methods for the efficient determination of PCDDs/Fs and dl-PCBs in contaminated soils.
Open AccessDeveloping an Improved Strategy for the Analysis of Polychlorinated Dibenzo-p-Dioxins/Furans and Dioxin-like Polychlorinated Biphenyls in Contaminated Soils Using a Combination of a One-Step Cleanup Method and Gas Chromatography with Triple Quadrupole Mass Spectrometry
Soils contaminated with polychlorodibenzo-p-dioxins (PCDDs), polychlorodibenzofurans (PCDFs), and dioxin-like (dl) polychlorinated biphenyls (PCBs), known as persistent organic pollutants (POPs), have garnered global attention because of their toxicity and persistence in the environment. The standard method for target analytes has been used; however, it is an obstacle in large-scale sample analysis due to the comprehensive sample preparation and high-cost instrumental analysis. Thus, analytical development of inexpensive methods with lower barriers to determine PCDDs/Fs and dl-PCBs in soil is needed. In this study, a one-step cleanup method was developed and validated by combining a multilayer silica gel column and Florisil micro-column followed by gas chromatography with triple quadrupole mass spectrometry (GC-QqQ-MS/MS). To optimize the separation and quantification of 17 PCDDs/Fs and 12 dl-PCBs in soils, the sample cleanup and instrumental conditions were investigated. For quantification method validation, spiking experiments were conducted to determine the linearity of the calibration, recovery, and method detection limit of PCDDs/Fs and dl-PCBs using isotopic dilution GC-QqQ-MS/MS. The applicability of the simultaneous determination of PCDDs/Fs and dl-PCBs was confirmed by the recovery of native target congeners and labeled surrogate congeners spiked into the quality-control and actual soil samples. The results were in good agreement with the requirements imposed by standard methods. The findings in this work demonstrated the high accessibility of the sample cleanup and analysis methods for the efficient determination of PCDDs/Fs and dl-PCBs in contaminated soils.