Robert C. Gorman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Robert C. Gorman has a total of 142 co-authors. Here are the top co-authors by number of shared publications:
- Joseph H. Gorman
Gorman Cardiovascular Research Group, University of Pennsylvania, Philadelphia, PA, USA
12 shared publications Joseph H. Gorman
Department of Surgery, Gorman Cardiovascular Research Group, University of Pennsylvania, Philadelphia, Pennsylvania
10 shared publicationsJames J. Pilla
From the Department of Bioengineering (C.B.R., N.N.D., S.M.D., J.A.B.), Gorman Cardiovascular Research Group, Department of Surgery (M.E.L., S.T., T.T., T.K., J.S.A., J.H.G., R.C.G.), and Department of Radiology (W.R.T.W., J.J.P.), University of Pennsylvania, Philadelphia; and Department of Mechanical Engineering (H.W., J.F.W.) and Department of Surgery (J.F.W.), University of Kentucky, Lexington
8 shared publications- Francisco Contijoch
Shu Chien-Gene Lay Department of Bioengineering, University of California San Diego, La Jolla, USA
6 shared publications - Joseph H. Gorman
Gorman Cardiovascular Research Group, University of Pennsylvania, Philadelphia, Pennsylvania; Department of Surgery, University of Pennsylvania, Philadelphia, Pennsylvania
6 shared publications Jeremy R. McGarvey
Gorman Cardiovascular Research Group, Department of Surgery, University of Pennsylvania, Philadelphia, Pennsylvania
5 shared publications
Latest Publications
- 1 January 2020
- Published by Elsevier in Seminars in Thoracic and Cardiovascular Surgery
- Vol. 32 (3) , 445-453
Injectable Shear-Thinning Hydrogels Prevent Ischemic Mitral Regurgitation and Normalize Ventricular Flow Dynamics
- 1 January 2020
- Published by Elsevier in Seminars in Thoracic and Cardiovascular Surgery
- Vol. 32 (3) , 445-453
Injectable Shear-Thinning Hydrogels Prevent Ischemic Mitral Regurgitation and Normalize Ventricular Flow Dynamics
- 1 December 2017
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 104 (6) , 1968-1975
Cardiac Progenitor Cell Recruitment Drives Fetal Cardiac Regeneration by Enhanced Angiogenesis
- 1 December 2017
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 104 (6) , 1968-1975
Cardiac Progenitor Cell Recruitment Drives Fetal Cardiac Regeneration by Enhanced Angiogenesis
- Open Access
- 1 December 2016
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 19 (1) , 1-10
Assessment of myocardial injury after reperfused infarction by T1ρ cardiovascular magnetic resonance
- 1 December 2016
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 19 (1) , 1-10
Open AccessAssessment of myocardial injury after reperfused infarction by T1ρ cardiovascular magnetic resonance
- 1 October 2016
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 102 (4) , 1414-1415
Reply
- 1 October 2016
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Interventions
- Vol. 9 (10)
Injectable Shear-Thinning Hydrogels for Minimally Invasive Delivery to Infarcted Myocardium to Limit Left Ventricular Remodeling
Background—: Injectable, acellular biomaterials hold promise to limit left ventricular remodeling and heart failure precipitated by infarction through bulking or stiffening the infarct region. A material with tunable properties (eg, mechanics, degradation) that can be delivered percutaneously has not yet been demonstrated. Catheter-deliverable soft hydrogels with in vivo stiffening to enhance therapeutic efficacy achieve these requirements. Methods and Results—: We developed a hyaluronic acid hydrogel that uses a tandem crosslinking approach, where the first crosslinking (guest–host) enabled injection and localized retention of a soft (50%; P P =0.014) and guest–host (15% improvement; P =0.058) treatments. Percutaneous delivery via endocardial injection was investigated with fluoroscopic and echocardiographic guidance, with delivery visualized by magnetic resonance imaging. Conclusions—: A percutaneous delivered hydrogel system was developed, and hydrogels with increased stiffness were found to be most effective in ameliorating left ventricular remodeling and preserving function. Ultimately, engineered systems such as these have the potential to provide effective clinical options to limit remodeling in patients after infarction.
- 1 October 2016
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Interventions
- Vol. 9 (10)
Injectable Shear-Thinning Hydrogels for Minimally Invasive Delivery to Infarcted Myocardium to Limit Left Ventricular Remodeling
Background—: Injectable, acellular biomaterials hold promise to limit left ventricular remodeling and heart failure precipitated by infarction through bulking or stiffening the infarct region. A material with tunable properties (eg, mechanics, degradation) that can be delivered percutaneously has not yet been demonstrated. Catheter-deliverable soft hydrogels with in vivo stiffening to enhance therapeutic efficacy achieve these requirements. Methods and Results—: We developed a hyaluronic acid hydrogel that uses a tandem crosslinking approach, where the first crosslinking (guest–host) enabled injection and localized retention of a soft (50%; P P =0.014) and guest–host (15% improvement; P =0.058) treatments. Percutaneous delivery via endocardial injection was investigated with fluoroscopic and echocardiographic guidance, with delivery visualized by magnetic resonance imaging. Conclusions—: A percutaneous delivered hydrogel system was developed, and hydrogels with increased stiffness were found to be most effective in ameliorating left ventricular remodeling and preserving function. Ultimately, engineered systems such as these have the potential to provide effective clinical options to limit remodeling in patients after infarction.
- Open Access
- 9 September 2016
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 15 (1) , 1-15
Patient-specific CFD simulation of intraventricular haemodynamics based on 3D ultrasound imaging
The goal of this paper is to present a computational fluid dynamic (CFD) model with moving boundaries to study the intraventricular flows in a patient-specific framework. Starting from the segmentation of real-time transesophageal echocardiographic images, a CFD model including the complete left ventricle and the moving 3D mitral valve was realized. Their motion, known as a function of time from the segmented ultrasound images, was imposed as a boundary condition in an Arbitrary Lagrangian–Eulerian framework. The model allowed for a realistic description of the displacement of the structures of interest and for an effective analysis of the intraventricular flows throughout the cardiac cycle. The model provides detailed intraventricular flow features, and highlights the importance of the 3D valve apparatus for the vortex dynamics and apical flow. The proposed method could describe the haemodynamics of the left ventricle during the cardiac cycle. The methodology might therefore be of particular importance in patient treatment planning to assess the impact of mitral valve treatment on intraventricular flow dynamics.
- 9 September 2016
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 15 (1) , 1-15
Open AccessPatient-specific CFD simulation of intraventricular haemodynamics based on 3D ultrasound imaging
The goal of this paper is to present a computational fluid dynamic (CFD) model with moving boundaries to study the intraventricular flows in a patient-specific framework. Starting from the segmentation of real-time transesophageal echocardiographic images, a CFD model including the complete left ventricle and the moving 3D mitral valve was realized. Their motion, known as a function of time from the segmented ultrasound images, was imposed as a boundary condition in an Arbitrary Lagrangian–Eulerian framework. The model allowed for a realistic description of the displacement of the structures of interest and for an effective analysis of the intraventricular flows throughout the cardiac cycle. The model provides detailed intraventricular flow features, and highlights the importance of the 3D valve apparatus for the vortex dynamics and apical flow. The proposed method could describe the haemodynamics of the left ventricle during the cardiac cycle. The methodology might therefore be of particular importance in patient treatment planning to assess the impact of mitral valve treatment on intraventricular flow dynamics.
- 1 September 2016
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 102 (3) , 796-802
Slice-by-Slice Pressure-Volume Loop Analysis Demonstrates Native Differences in Regional Cardiac Contractility and Response to Inotropic Agents
- 1 September 2016
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 102 (3) , 796-802
Slice-by-Slice Pressure-Volume Loop Analysis Demonstrates Native Differences in Regional Cardiac Contractility and Response to Inotropic Agents
- 2 September 2015
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 43 (3) , 585-593
Impact of end‐diastolic and end‐systolic phase selection in the volumetric evaluation of cardiac MRI
Purpose: To evaluate the impact of end‐diastolic (ED) and end‐systolic (ES) cardiac phase selection methods, since task force recommendations have neither provided quantitative evidence nor explored errors introduced by clinical shortcuts.Materials and Methods: Multislice, short‐axis cine images were collected in 60 clinical patients on a 1.5T scanner. User‐initialized active contour segmentation software quantified global left ventricular (LV) volume across all cardiac phases. Different approaches for selection of ED and ES phase were evaluated by quantification of temporal and volumetric errors.Results: For diastole, the mid‐ventricular maximum slice volume coincided with maximum global volume in 82.1% of patients with ejection fraction (EF) ≥55% (P = 0.66) and 71.9% of patients with EF P = 0.28) and is an accurate approximation of maximum global volume while the first and last phases in a retrospectively electrocardiogram (ECG)‐gated acquisition introduced differences in cardiac phase selection (P < 0.001) which led to large errors in measured volume in some patients (12.7 and 10.1 mL, respectively). For systole, post‐systolic shortening occurred in a significantly higher number of patients with EF P = 0.001), which differentially impacted end‐systolic volume estimation.Conclusion: For end‐diastolic phase selection, our results indicated that the use of the mid‐ventricular slice volume maximum provided accurate volume estimates, while selection of the first or last cardiac phase introduced differences in measured volume. For end‐systolic phase, patients with EF <55% had a higher prevalence of post‐systolic shortening, which suggests aortic valve closure should be used to estimate end‐systolic volume. J. MAGN. RESON. IMAGING 2016;43:585–593.
- 2 September 2015
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 43 (3) , 585-593
Impact of end‐diastolic and end‐systolic phase selection in the volumetric evaluation of cardiac MRI
Purpose: To evaluate the impact of end‐diastolic (ED) and end‐systolic (ES) cardiac phase selection methods, since task force recommendations have neither provided quantitative evidence nor explored errors introduced by clinical shortcuts.Materials and Methods: Multislice, short‐axis cine images were collected in 60 clinical patients on a 1.5T scanner. User‐initialized active contour segmentation software quantified global left ventricular (LV) volume across all cardiac phases. Different approaches for selection of ED and ES phase were evaluated by quantification of temporal and volumetric errors.Results: For diastole, the mid‐ventricular maximum slice volume coincided with maximum global volume in 82.1% of patients with ejection fraction (EF) ≥55% (P = 0.66) and 71.9% of patients with EF P = 0.28) and is an accurate approximation of maximum global volume while the first and last phases in a retrospectively electrocardiogram (ECG)‐gated acquisition introduced differences in cardiac phase selection (P < 0.001) which led to large errors in measured volume in some patients (12.7 and 10.1 mL, respectively). For systole, post‐systolic shortening occurred in a significantly higher number of patients with EF P = 0.001), which differentially impacted end‐systolic volume estimation.Conclusion: For end‐diastolic phase selection, our results indicated that the use of the mid‐ventricular slice volume maximum provided accurate volume estimates, while selection of the first or last cardiac phase introduced differences in measured volume. For end‐systolic phase, patients with EF <55% had a higher prevalence of post‐systolic shortening, which suggests aortic valve closure should be used to estimate end‐systolic volume. J. MAGN. RESON. IMAGING 2016;43:585–593.
- Open Access
- 1 September 2015
- Vol. 4 (5) , 461-462-462
4D-transesophageal echocardiography and emerging imaging modalities for guiding mitral valve repair
- 1 September 2015
- Vol. 4 (5) , 461-462-462
Open Access4D-transesophageal echocardiography and emerging imaging modalities for guiding mitral valve repair
- 1 March 2015
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 99 (3) , 770-778
Regional Myocardial Three-Dimensional Principal Strains During Postinfarction Remodeling
- 1 March 2015
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 99 (3) , 770-778
Regional Myocardial Three-Dimensional Principal Strains During Postinfarction Remodeling