B. Ohnesorge
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
B. Ohnesorge has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
A. Crispin
Department of Clinical Radiology, Grosshadern Clinic, University of Munich, Marchioninistrasse 15, 81377 Munich, Germany
1 shared publicationA. Knez
Department of Cardiology, Grosshadern Clinic, University of Munich, Marchioninistrasse 15, 81377 Munich, Germany
1 shared publicationA. Kopp
Department of Clinical Radiology, University of Tübingen, Hoppe-Seyler-Strasse 3, 72076 Tübingen, Germany
1 shared publicationC. Becker
Department of Clinical Radiology, Grosshadern Clinic, University of Munich, Marchioninistrasse 15, 81377 Munich, Germany
1 shared publicationE. Klotz
Siemens Medical Solutions, Division CT, CTS C, Siemensstrasse 1, 91301 Forchheim, Germany
1 shared publicationM. Reiser
Department of Clinical Radiology, Grosshadern Clinic, University of Munich, Marchioninistrasse 15, 81377 Munich, Germany
1 shared publication
Latest Publications
- Open Access
- 19 April 2002
- Published by Springer Nature in European Radiology
- Vol. 12 (6) , 1532-1540
Reproducibility of coronary calcium quantification in repeat examinations with retrospectively ECG-gated multisection spiral CT
High reproducibility is a key requirement for coronary calcium scoring in follow-up examinations. We investigated the inter-examination reproducibility of calcium scoring with retrospectively ECG-gated multisection spiral CT (MSCT). Fifty patients were examined twice with MSCT. Slices were reconstructed with retrospective ECG gating in the diastolic phase with 3-mm slice width and up to 125-ms temporal resolution. We calculated the Agatston score, calcium volume with and without isotropic interpolation, and calcium mass, and derived the mean and median variability. We investigated the change of variability with use of 3-mm non-overlapping and overlapping increments (2, 1.5, 1 mm). Use of overlapping increment results in considerably reduced interscan variability. We observed a minimum mean variability of 12% and a minimum median variability of 9% for the Agatston score. For volume and mass quantification we obtained a minimum mean variability of 7.5% and a minimum median variability of 5%. Multisection spiral CT enables coronary calcium quantification with high reproducibility in follow-up examinations mainly founded on image data with reduced partial-volume errors due to overlapping increment.
- 19 April 2002
- Published by Springer Nature in European Radiology
- Vol. 12 (6) , 1532-1540
Open AccessReproducibility of coronary calcium quantification in repeat examinations with retrospectively ECG-gated multisection spiral CT
High reproducibility is a key requirement for coronary calcium scoring in follow-up examinations. We investigated the inter-examination reproducibility of calcium scoring with retrospectively ECG-gated multisection spiral CT (MSCT). Fifty patients were examined twice with MSCT. Slices were reconstructed with retrospective ECG gating in the diastolic phase with 3-mm slice width and up to 125-ms temporal resolution. We calculated the Agatston score, calcium volume with and without isotropic interpolation, and calcium mass, and derived the mean and median variability. We investigated the change of variability with use of 3-mm non-overlapping and overlapping increments (2, 1.5, 1 mm). Use of overlapping increment results in considerably reduced interscan variability. We observed a minimum mean variability of 12% and a minimum median variability of 9% for the Agatston score. For volume and mass quantification we obtained a minimum mean variability of 7.5% and a minimum median variability of 5%. Multisection spiral CT enables coronary calcium quantification with high reproducibility in follow-up examinations mainly founded on image data with reduced partial-volume errors due to overlapping increment.