TKThomas Kahn

Thomas Kahn

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Thomas Kahn has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Analysis of Patients’ X-ray Exposure in 146 Percutaneous Radiologic Gastrostomies

    by Tim-Ole Petersen, Martin Reinhardt, Jochen Fuchs, Dieter Gosch, Alexey Surov, Patrick Stumpp, Thomas Kahn, Michael Moche

    Purpose Analysis of patient´s X-ray exposure during percutaneous radiologic gastrostomies (PRG) in a larger population. Materials and Methods Data of primary successful PRG-procedures, performed between 2004 and 2015 in 146 patients, were analyzed regarding the exposition to X-ray. Dose-area-product (DAP), dose-length-product (DLP) respectively, and fluoroscopy time (FT) were correlated with the used x-ray systems (Flatpanel Detector (FD) vs. Image Itensifier (BV)) and the necessity for periprocedural placement of a nasogastric tube. Additionally, the effective X-ray dose for PRG placement using fluoroscopy (DL), computed tomography (CT), and cone beam CT (CBCT) was estimated using a conversion factor. Results The median DFP of PRG-placements under fluoroscopy was 163 cGy*cm2 (flat panel detector systems: 155 cGy*cm2; X-ray image intensifier: 175 cGy*cm2). The median DLZ was 2.2 min. Intraprocedural placement of a naso- or orogastric probe (n = 68) resulted in a significant prolongation of the median DLZ to 2.5 min versus 2 min in patients with an already existing probe. In addition, dose values were analyzed in smaller samples of patients in which the PRG was placed under CBCT (n = 7, median DFP = 2635 cGy*cm2), or using CT (n = 4, median DLP = 657 mGy*cm). Estimates of the median DFP and DLP showed effective doses of 0.3 mSv for DL-assisted placements (flat panel detector 0.3 mSv, X-ray image converter 0.4 mSv), 7.9 mSv using a CBCT – flat detector, and 9.9 mSv using CT. This corresponds to a factor 26 of DL versus CBCT, or a factor 33 of DL versus CT. Conclusion In order to minimize X-ray exposure during PRG-procedures for patients and staff, fluoroscopically-guided interventions should employ flat detector systems with short transmittance sequences in low dose mode and with slow image frequency. Series recordings can be dispensed with. The intraprocedural placement of a naso- or orogastric probe significantly extends FT, but has little effect on the overall dose of the intervention. Due to the significantly higher X-ray exposure, the use of a CBCT as well as PRG-placements using CT should be limited to clinically absolutely necessary exceptions with strict indication. Key Points Citation Format


  • Navigation Techniques for MRI-Guided Interventions

    by Harald Busse, Thomas Kahn, Michael Moche

  • Suitability of miniature inductively coupled RF coils as MR‐visible markers for clinical purposes

    by Nikita Garnov, Gregor Thörmer, Robert Trampel, Wilfried Gründer, Thomas Kahn, Michael Moche, Harald Busse

    Purpose: MR-visible markers have already been used for various purposes such as image registration, motion detection, and device tracking. Inductively coupled RF (ICRF) coils, in particular, provide a high contrast and do not require connecting wires to the scanner, which makes their application highly flexible and safe. This work aims to thoroughly characterize the MR signals of such ICRF markers under various conditions with a special emphasis on fully automatic detection. Methods: The small markers consisted of a solenoid coil that was wound around a glass tube containing the MR signal source and tuned to the resonance frequency of a 1.5 T MRI. Marker imaging was performed with a spoiled gradient echo sequence (FLASH) and a balanced steady-state free precession (SSFP) sequence (TrueFISP) in three standard projections. The signal intensities of the markers were recorded for both pulse sequences, three source materials (tap water, distilled water, and contrast agent solution), different flip angles and coil alignments with respect to theB 0 direction as well as for different marker positions in the entire imaging volume (field of view, FOV). Heating of the ICRF coils was measured during 10-min RF expositions to three conventional pulse sequences. Clinical utility of the markers was assessed from their performance in computer-aided detection and in defining double oblique scan planes. Results: For almost the entire FOV (±215 mm) and an estimated 82% of all possible RF coil alignments with respect toB 0, the ICRF markers generated clearly visible MR signals and could be reliably localized over a large range of flip angles, in particular with the TrueFISP sequence (0.3°–4.0°). Generally, TrueFISP provided a higher marker contrast than FLASH. RF exposition caused a moderate heating (≤5 °C) of the ICRF coils only. Conclusions : Small ICRF coils,imaged at low flip angles with a balanced SSFP sequence showed an excellent performance under a variety of experimental conditions and therefore make for a reliable, compact, flexible, and relatively safe marker for clinical use


    • 1 January 2003
      • Vol. 13  (3)

    [Clinical use of interventional MR imaging].

    by Thomas Kahn, Thomas Schulz, Michael Moche, Sascha Prothmann, Jens-Peter Schneider

  • MRT-gestützte laserinduzierte Thermoablation bei Lebertumoren – Klinische Aspekte und Konzept eines Überwachungssystems

    by Nils-Karsten Bär, Thomas Schulz, Silvia Puccini, Timo Schirmer, Thomas Kahn, Harald Busse


  • Klinischer Einsatz der interventionellen MRT (iMRT)

    by Thomas Kahn, Thomas Schulz, Michael Moche, Sascha Prothmann, Jens-Peter Schneider