Xianggen Yin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Xianggen Yin has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Zhe Zhang
State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, 1037 Luoyu Road, Wuhan 430074, China
4 shared publications - Chuan-Qi Wang
Huazhong University of Science and Technology
2 shared publications Deshu Chen
Senior Member, IEEE, College of Electrical and Electronic Engineering, Huazhong University of Science and Technology (HUST), Wuhan 430074, Hubei, China
2 shared publications- Hang Li
Wuhan Power Supply Company, State Grid Hubei Electric Power Company, Wuhan 430013
2 shared publications Wei Chen
Member, IEEE, College of Electrical and Electronic Engineering, Huazhong University of Science and Technology (HUST), Wuhan 430074, Hubei, China
2 shared publications- Xiangli Deng
Huazhong University of Science and Technology
2 shared publications
Latest Publications
- Open Access
Multi-Information Fusion-Based Hierarchical Power Generation-Side Protection System
With renewable power sources and new topology structures being widely introduced into the power system, the current local information-based power generation-side protection cannot fully guarantee the protection performance and the safety coordination with the power grid. This paper proposes an improved hierarchical protection system on the power generation-side. The proposed system takes advantage of the fusion of multi-information provided by the system, station and local layers. The system layer provides the information such as system voltage control and power regulation demand, so that the generation-side protection and control system can adapt to the system operation mode and power regulation demand. The station layer realizes the coordination of the protection principle and action strategy among the related units through information interaction with the power grid, the automatic control system and the local layer protection. The local layer introduces the condition monitoring information and more abundant protection information to enhance the protection performance and master the generation units’ safety condition. To illustrate the hierarchical protection system construction method and actual application mode, the multi-information fusion-based comprehensive local layer protection method and the multi-generators information fusion-based hierarchical protection method are taken as examples. Case analysis shows that the proposed methods can reflect more slight internal fault forms and can adaptively determine the protection action characteristic and tripping strategy according to the system operating conditions and other generators’ fault conditions, which effectively improve the protection sensitivity and coordination capability. To provide reference and inspiration for follow-up research, the hierarchical protection system construction mode, communication technology and research approaches of new protection methods are further pointed out.
Open AccessMulti-Information Fusion-Based Hierarchical Power Generation-Side Protection System
With renewable power sources and new topology structures being widely introduced into the power system, the current local information-based power generation-side protection cannot fully guarantee the protection performance and the safety coordination with the power grid. This paper proposes an improved hierarchical protection system on the power generation-side. The proposed system takes advantage of the fusion of multi-information provided by the system, station and local layers. The system layer provides the information such as system voltage control and power regulation demand, so that the generation-side protection and control system can adapt to the system operation mode and power regulation demand. The station layer realizes the coordination of the protection principle and action strategy among the related units through information interaction with the power grid, the automatic control system and the local layer protection. The local layer introduces the condition monitoring information and more abundant protection information to enhance the protection performance and master the generation units’ safety condition. To illustrate the hierarchical protection system construction method and actual application mode, the multi-information fusion-based comprehensive local layer protection method and the multi-generators information fusion-based hierarchical protection method are taken as examples. Case analysis shows that the proposed methods can reflect more slight internal fault forms and can adaptively determine the protection action characteristic and tripping strategy according to the system operating conditions and other generators’ fault conditions, which effectively improve the protection sensitivity and coordination capability. To provide reference and inspiration for follow-up research, the hierarchical protection system construction mode, communication technology and research approaches of new protection methods are further pointed out.
- Open Access
A Novel Probabilistic Power Flow Algorithm Based on Principal Component Analysis and High-Dimensional Model Representation Techniques
Because the penetration level of renewable energy sources has increased rapidly in recent years, uncertainty in power system operation is gradually increasing. As an efficient tool for power system analysis under uncertainty, probabilistic power flow (PPF) is becoming increasingly important. The point-estimate method (PEM) is a well-known PPF algorithm. However, two significant defects limit the practical use of this method. One is that the PEM struggles to estimate high-order moments accurately; this defect makes it difficult for the PEM to describe the distribution of non-Gaussian output random variables (ORVs). The other is that the calculation burden is strongly related to the scale of input random variables (IRVs), which makes the PEM difficult to use in large-scale power systems. A novel approach based on principal component analysis (PCA) and high-dimensional model representation (HDMR) is proposed here to overcome the defects of the traditional PEM. PCA is applied to decrease the dimension scale of IRVs and eliminate correlations. HDMR is applied to estimate the moments of ORVs. Because HDMR considers the cooperative effects of IRVs, it has a significantly smaller estimation error for high-order moments in particular. Case studies show that the proposed method can achieve a better performance in terms of accuracy and efficiency than traditional PEM.
Open AccessA Novel Probabilistic Power Flow Algorithm Based on Principal Component Analysis and High-Dimensional Model Representation Techniques
Because the penetration level of renewable energy sources has increased rapidly in recent years, uncertainty in power system operation is gradually increasing. As an efficient tool for power system analysis under uncertainty, probabilistic power flow (PPF) is becoming increasingly important. The point-estimate method (PEM) is a well-known PPF algorithm. However, two significant defects limit the practical use of this method. One is that the PEM struggles to estimate high-order moments accurately; this defect makes it difficult for the PEM to describe the distribution of non-Gaussian output random variables (ORVs). The other is that the calculation burden is strongly related to the scale of input random variables (IRVs), which makes the PEM difficult to use in large-scale power systems. A novel approach based on principal component analysis (PCA) and high-dimensional model representation (HDMR) is proposed here to overcome the defects of the traditional PEM. PCA is applied to decrease the dimension scale of IRVs and eliminate correlations. HDMR is applied to estimate the moments of ORVs. Because HDMR considers the cooperative effects of IRVs, it has a significantly smaller estimation error for high-order moments in particular. Case studies show that the proposed method can achieve a better performance in terms of accuracy and efficiency than traditional PEM.
- Open Access
Preventive Security-Constrained Optimal Power Flow with Probabilistic Guarantees
The traditional security-constrained optimal power flow (SCOPF) model under the classical N-1 criterion is implemented in the power industry to ensure the secure operation of a power system. However, with increasing uncertainties from renewable energy sources (RES) and loads, the existing SCOPF model has difficulty meeting the practical requirements of the industry. This paper proposed a novel chance-constrained preventive SCOPF model that considers the uncertainty of power injections, including RES and load, and contingency probability. The chance constraint is used to constrain the overall line flow within the limits with high probabilistic guarantees and to significantly reduce the constraint scales. The cumulant and Johnson systems were combined to accurately approximate the cumulative distribution functions, which is important in solving chance-constrained optimization problems. The simulation results show that the model proposed in this paper can achieve better performance than traditional SCOPF.
Open AccessPreventive Security-Constrained Optimal Power Flow with Probabilistic Guarantees
The traditional security-constrained optimal power flow (SCOPF) model under the classical N-1 criterion is implemented in the power industry to ensure the secure operation of a power system. However, with increasing uncertainties from renewable energy sources (RES) and loads, the existing SCOPF model has difficulty meeting the practical requirements of the industry. This paper proposed a novel chance-constrained preventive SCOPF model that considers the uncertainty of power injections, including RES and load, and contingency probability. The chance constraint is used to constrain the overall line flow within the limits with high probabilistic guarantees and to significantly reduce the constraint scales. The cumulant and Johnson systems were combined to accurately approximate the cumulative distribution functions, which is important in solving chance-constrained optimization problems. The simulation results show that the model proposed in this paper can achieve better performance than traditional SCOPF.
- 31 October 2013
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 55, 497-502
An energy differential relay for long transmission lines
- 31 October 2013
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 55, 497-502
An energy differential relay for long transmission lines
- 13 March 2012
- Published by Springer Nature
- p. 1103-1110
An Innovative Protective Algorithm for UHV Power Transformer
- 13 March 2012
- Published by Springer Nature
- p. 1103-1110
An Innovative Protective Algorithm for UHV Power Transformer
- 13 March 2012
- Published by Springer Nature
- p. 1119-1126
Fast Unrestrained Differential Protection Based on Phaselet Algorithm
- 13 March 2012
- Published by Springer Nature
- p. 1119-1126
Fast Unrestrained Differential Protection Based on Phaselet Algorithm
- 1 October 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Transient Simulation Model and Its Simplified Method Validation for Huge Hydro Generator Internal Short Circuit Faults
Based on the summary of the research about internal short circuit faults and the main protection scheme for huge multi-branch hydro generator, the significance to research transient process in faulty condition is pointed out in the paper. By far, there almost have no perfect simulation model suits for generator optimized main protection scheme research based on internal fault transient process simulation. In this paper, the theory and validation of the simplified transient simulation model, which based on ldquodual damper bars on each polerdquo principle is proposed and explained. The simplified transient simulation model can satisfy the demands for engineering application both on calculation precision and on solving speed, so its merit for engineering practicality is demonstrated, and it provides a new approach for optimized main protection scheme research for huge hydro generator.
- 1 October 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Transient Simulation Model and Its Simplified Method Validation for Huge Hydro Generator Internal Short Circuit Faults
Based on the summary of the research about internal short circuit faults and the main protection scheme for huge multi-branch hydro generator, the significance to research transient process in faulty condition is pointed out in the paper. By far, there almost have no perfect simulation model suits for generator optimized main protection scheme research based on internal fault transient process simulation. In this paper, the theory and validation of the simplified transient simulation model, which based on ldquodual damper bars on each polerdquo principle is proposed and explained. The simplified transient simulation model can satisfy the demands for engineering application both on calculation precision and on solving speed, so its merit for engineering practicality is demonstrated, and it provides a new approach for optimized main protection scheme research for huge hydro generator.
- 1 October 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
The Study of Transient Performance of Current Sensor Based on Rogowski Coil and Its Application in Dynamic Simulation Experiment
MCT connected in circuit alters internal electrical parameters of generator. This means the generator mathematical model isn't identical with the generator in experiment. This makes the generator modeling more complicated. Rogowski coil doesn't contact with measured circuit. It won't change parameters of generator. Based on simulation and experiment, the paper introduces a current sensor composed of Rogowski coil and properly designed active integrator. Tests show the sensor has a good ratio error and linearity. Moreover, the output of the sensor can reproduce transient fault current well. In a dynamic generator internal fault experiment, waveforms from digital simulation, MCT and the sensor were contrasted. The result shows that the output of the sensor is closer to the digital simulation result waveform. Applying the sensor in generator simulation research will make the task convenient.
- 1 October 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
The Study of Transient Performance of Current Sensor Based on Rogowski Coil and Its Application in Dynamic Simulation Experiment
MCT connected in circuit alters internal electrical parameters of generator. This means the generator mathematical model isn't identical with the generator in experiment. This makes the generator modeling more complicated. Rogowski coil doesn't contact with measured circuit. It won't change parameters of generator. Based on simulation and experiment, the paper introduces a current sensor composed of Rogowski coil and properly designed active integrator. Tests show the sensor has a good ratio error and linearity. Moreover, the output of the sensor can reproduce transient fault current well. In a dynamic generator internal fault experiment, waveforms from digital simulation, MCT and the sensor were contrasted. The result shows that the output of the sensor is closer to the digital simulation result waveform. Applying the sensor in generator simulation research will make the task convenient.