Marko Mikuz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Marko Mikuz has a total of 177 co-authors. Here are the top co-authors by number of shared publications:
- Igor Mandic
University of Ljubljana
6 shared publications - Gregor Kramberger
University of Ljubljana
4 shared publications V. Cindro
Institute Jozef Stefan
4 shared publicationsM. Zavrtanik
Jožef Stefan Institute, Ljubljana, Slovenia
3 shared publicationsA. Angelopoulos
2 shared publicationsA. Apostolakis
2 shared publications
Latest Publications
- 1 April 2016
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 11 (4) , P04007
Charge collection studies in irradiated HV-CMOS particle detectors
Charge collection properties of particle detectors made in HV-CMOS technology were investigated before and after irradiation with reactor neutrons. Two different sensor types were designed and processed in 180 and 350 nm technology by AMS. Edge-TCT and charge collection measurements with electrons from 90Sr source were employed. Diffusion of generated carriers from undepleted substrate contributes significantly to the charge collection before irradiation, while after irradiation the drift contribution prevails as shown by charge measurements at different shaping times. The depleted region at a given bias voltage was found to grow with irradiation in the fluence range of interest for strip detectors at the HL-LHC. This leads to large gains in the measured charge with respect to the one before irradiation. The increase of the depleted region was attributed to removal of effective acceptors. The evolution of depleted region with fluence was investigated and modeled. Initial studies show a small effect of short term annealing on charge collection.
- 1 April 2016
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 11 (4) , P04007
Charge collection studies in irradiated HV-CMOS particle detectors
Charge collection properties of particle detectors made in HV-CMOS technology were investigated before and after irradiation with reactor neutrons. Two different sensor types were designed and processed in 180 and 350 nm technology by AMS. Edge-TCT and charge collection measurements with electrons from 90Sr source were employed. Diffusion of generated carriers from undepleted substrate contributes significantly to the charge collection before irradiation, while after irradiation the drift contribution prevails as shown by charge measurements at different shaping times. The depleted region at a given bias voltage was found to grow with irradiation in the fluence range of interest for strip detectors at the HL-LHC. This leads to large gains in the measured charge with respect to the one before irradiation. The increase of the depleted region was attributed to removal of effective acceptors. The evolution of depleted region with fluence was investigated and modeled. Initial studies show a small effect of short term annealing on charge collection.
- Open Access
- 22 August 2013
- Published by Sissa Medialab Srl
- Vol. 174, 524
Diamond sensors in HEP
With the first three years of the LHC running well underway, and luminosity upgrades expected towards the end of the decade, ATLAS and CMS are planning to upgrade their innermost tracking layers with the utmost radiation hard technologies. Chemical Vapour Deposition (CVD) diamond has been used extensively in beam conditions monitors as the innermost detectors in the highest radiation areas of BaBar, Belle, CDF and all LHC experiments. This material is now being considered as a sensor material for the innermost layer(s) of the upgraded trackers. Recently the CERN RD42 collaboration constructed, irradiated and tested polycrystalline and single-crystal CVD diamond sensors to the highest fluences expected at the innermost tracking layers of the HL-LHC. We present beam test results of chemical vapour deposition diamond to fluences in excess of 10 16 protons/cm 2 illustrating that both polycrystalline and single-crystal chemical vapour deposition diamonds follow a single damage curve. We briefly describe the performance of the diamond-based ATLAS beam monitoring devices and discuss plans for their upgrade to a diamond tracker during the 2013/14 LHC consolidation shutdown .
- 22 August 2013
- Published by Sissa Medialab Srl
- Vol. 174, 524
Open AccessDiamond sensors in HEP
With the first three years of the LHC running well underway, and luminosity upgrades expected towards the end of the decade, ATLAS and CMS are planning to upgrade their innermost tracking layers with the utmost radiation hard technologies. Chemical Vapour Deposition (CVD) diamond has been used extensively in beam conditions monitors as the innermost detectors in the highest radiation areas of BaBar, Belle, CDF and all LHC experiments. This material is now being considered as a sensor material for the innermost layer(s) of the upgraded trackers. Recently the CERN RD42 collaboration constructed, irradiated and tested polycrystalline and single-crystal CVD diamond sensors to the highest fluences expected at the innermost tracking layers of the HL-LHC. We present beam test results of chemical vapour deposition diamond to fluences in excess of 10 16 protons/cm 2 illustrating that both polycrystalline and single-crystal chemical vapour deposition diamonds follow a single damage curve. We briefly describe the performance of the diamond-based ATLAS beam monitoring devices and discuss plans for their upgrade to a diamond tracker during the 2013/14 LHC consolidation shutdown .
- 1 June 2012
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 7 (06) , P06007
Effects of accelerated long term annealing in highly irradiated n+-p strip detector examined by Edge-TCT
- 1 June 2012
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 7 (06) , P06007
Effects of accelerated long term annealing in highly irradiated n+-p strip detector examined by Edge-TCT
- 22 December 2010
- Published by Springer Nature
- p. 141-159
Basic Principles of Detection of Ionizing Radiation Used in Medical Imaging
- 22 December 2010
- Published by Springer Nature
- p. 141-159
Basic Principles of Detection of Ionizing Radiation Used in Medical Imaging
- 1 January 2009
- Published by Springer Nature in IFMBE Proceedings
- p. 577-580
Localization of high dose rate 192Ir source during brachytherapy treatment using silicon detectors
- 1 January 2009
- Published by Springer Nature in IFMBE Proceedings
- p. 577-580
Localization of high dose rate 192Ir source during brachytherapy treatment using silicon detectors
- 25 August 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2, 909-913 vol.2
Influence of trapping on silicon microstrip detector design and performance
New systematic measurements of effective carrier trapping times were used as an input to simulation of irradiated silicon strip detector operation. Charge collection efficiency (CCE) dependence on bias voltage, magnetic field, irradiation particle type, fluence and detector design was investigated. It was observed, that irradiated detectors processed on standard n-silicon material with n/sup +/ strips performed better than those with p/sup +/ strips. At /spl Phi//sub eq/ = 2 /spl times/ 10/sup 14/ cm/sup -2/ the difference is around 10% at voltages well above V/sub FD/ and even larger for lower voltages. A few percent difference in CCE for different track paths across the strip is predicted. Effective Lorentz angle was found to be independent on irradiation level. A non-negligible amount of charge appears also on neighboring strips as a consequence of charge trapping. The influence of detector thickness and strip width on induced charge was also studied.
- 25 August 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2, 909-913 vol.2
Influence of trapping on silicon microstrip detector design and performance
New systematic measurements of effective carrier trapping times were used as an input to simulation of irradiated silicon strip detector operation. Charge collection efficiency (CCE) dependence on bias voltage, magnetic field, irradiation particle type, fluence and detector design was investigated. It was observed, that irradiated detectors processed on standard n-silicon material with n/sup +/ strips performed better than those with p/sup +/ strips. At /spl Phi//sub eq/ = 2 /spl times/ 10/sup 14/ cm/sup -2/ the difference is around 10% at voltages well above V/sub FD/ and even larger for lower voltages. A few percent difference in CCE for different track paths across the strip is predicted. Effective Lorentz angle was found to be independent on irradiation level. A non-negligible amount of charge appears also on neighboring strips as a consequence of charge trapping. The influence of detector thickness and strip width on induced charge was also studied.
- 26 June 2000
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 45 (7) , 2029-2041
Design optimization of a breast imaging system based on silicon microstrip detectors
A mammographic imaging set-up using silicon microstrip detectors in edge-on geometry was simulated using the GEANT package. Deposited energy in tissue of various thicknesses was evaluated and shown to agree to within 10% with reference calculations. Optimal energies as well as spectra for mammography with silicon detectors were determined by maximizing the figure of merit of a realistic imaging set-up. The scattered to primary radiation ratio was studied for various detector geometries. It was found that fan-shaped detectors are needed to maintain the image quality for divergent photon beams.
- 26 June 2000
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 45 (7) , 2029-2041
Design optimization of a breast imaging system based on silicon microstrip detectors
A mammographic imaging set-up using silicon microstrip detectors in edge-on geometry was simulated using the GEANT package. Deposited energy in tissue of various thicknesses was evaluated and shown to agree to within 10% with reference calculations. Optimal energies as well as spectra for mammography with silicon detectors were determined by maximizing the figure of merit of a realistic imaging set-up. The scattered to primary radiation ratio was studied for various detector geometries. It was found that fan-shaped detectors are needed to maintain the image quality for divergent photon beams.
- 1 April 2000
- Published by Taylor & Francis in Philosophical Magazine Part B
- Vol. 80 (4) , 811-815
Irradiated silicon detectors operated at cryogenic temperatures: The Lazarus effect
An increasing interest in the behaviour of silicon detectors at cryogenic temperatures has been awakened by the discovery of the so-called Lazarus effect, namely the recovery of charge collection efficiency (CCE) by means of cryogenic cooling. We measured the CCEs of three single diodes previously irradiated with different neutron fluences. The current-voltage characteristic were measured at 300 and 77 K, showing that the low-temperature operation considerably decreases the steady-state current. This is also the case when a forward voltage bias is applied, which then becomes a suitable option. At 77 K, in the case of samples irradiated with 5 × 1014 neutrons cm−2, the CCE is completely recovered. A third sample irradiated with 2 × 1015 neutrons cm−2 shows a 60% CCE at 250 V forward bias.
- 1 April 2000
- Published by Taylor & Francis in Philosophical Magazine Part B
- Vol. 80 (4) , 811-815
Irradiated silicon detectors operated at cryogenic temperatures: The Lazarus effect
An increasing interest in the behaviour of silicon detectors at cryogenic temperatures has been awakened by the discovery of the so-called Lazarus effect, namely the recovery of charge collection efficiency (CCE) by means of cryogenic cooling. We measured the CCEs of three single diodes previously irradiated with different neutron fluences. The current-voltage characteristic were measured at 300 and 77 K, showing that the low-temperature operation considerably decreases the steady-state current. This is also the case when a forward voltage bias is applied, which then becomes a suitable option. At 77 K, in the case of samples irradiated with 5 × 1014 neutrons cm−2, the CCE is completely recovered. A third sample irradiated with 2 × 1015 neutrons cm−2 shows a 60% CCE at 250 V forward bias.
- 1 January 2000
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 549 (1) , 957
First direct observation of time-reversal violation
Using its unique capability of strangeness tagging at production in and at decay with the lepton charge in semileptonic decays CPLEAR measured the semileptonic decay-rate asymmetry The asymmetry, fitted over the eigentime interval 1–20 yielded a non-zero result of A thorough phenomenological anaylsis identifies T violation in mixing and/or CPT violation in semileptonic decays as possible interpretations. A confrontation with world data on neutral kaon decays, however, excludes the latter with sufficient precision to establish the result as the first direct observation of time reversal non-invariance.- 1 January 2000
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 549 (1) , 957
First direct observation of time-reversal violation
Using its unique capability of strangeness tagging at production in and at decay with the lepton charge in semileptonic decays CPLEAR measured the semileptonic decay-rate asymmetry The asymmetry, fitted over the eigentime interval 1–20 yielded a non-zero result of A thorough phenomenological anaylsis identifies T violation in mixing and/or CPT violation in semileptonic decays as possible interpretations. A confrontation with world data on neutral kaon decays, however, excludes the latter with sufficient precision to establish the result as the first direct observation of time reversal non-invariance.- 1 January 2000
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 540 (1) , 305
Experimental tests of CPT invaŕiance
The CPLEAR experiment at CERN has directly studied matter and antimatter symmetries via the measurement of the time evolution of and The CPT violation parameter was directly measured with a precision of a few while is determined from the Bell-Steinberger relation, with a precision of The mass and decay-width equality between the and were tested down to the level of- 1 January 2000
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 540 (1) , 305
Experimental tests of CPT invaŕiance
The CPLEAR experiment at CERN has directly studied matter and antimatter symmetries via the measurement of the time evolution of and The CPT violation parameter was directly measured with a precision of a few while is determined from the Bell-Steinberger relation, with a precision of The mass and decay-width equality between the and were tested down to the level of