  • Coupled Pump and Pipe System Analysis for Optimum Design of District Heating System

    by Magnus Thor Jonsson, Lilja Magnusdottir

    This paper describes a novel approach for optimizing a district heating distribution network under various flow rate conditions. For district heating systems, the demand or the flow and pressure at each node varies over the time of year. The flow control that affects the operational cost can be based on the variable speed and the on/off control on serial pumping or pressure controlled valves. In the pipe system design, the topology, or the pipe layout, and the pipe diameter is optimized using genetic algorithms. Standardized methods are used for calculating the pipe thickness, supports, anchors and the thermal expansion loops. The interconnection between the pipe system and the pump station design is discussed. The objective is to minimize the total or life cycle cost (capital maintenance and operational cost), subject to ensuring demands or constraints at all points. The results are compared to classical methods where the pump station and the pipe system are designed separately and the improvements are discussed. The problem is formulated by developing an objective function where the optimization parameters define the pump arrangement, pipe system topology, and pipe diameters. The pump station and pipe system optimization consist of selecting components from a pre-defined set of elements and is implemented with discrete decision variables. Optimization of pipe elements consists of optimizing the diameter, after the topology has been defined, and is implemented with discrete variables. Flow distribution and pressure analysis is performed. Thicknesses, pressure classes, supports, expansion loops and anchors are not part of the optimization parameters, but are determined during the evaluation of the objective function. Each time the objective function is evaluated, the pipe system is designed in a sub-optimization according to given loads. The pressure head constraints are used to design the pumping curves. The method is tested on a district heating system in Reykjavik, Iceland.

  • Minimizing Visual Effects and Optimizing Routes and Locations for Geothermal Steam Gathering System

    by Magnus Thor Jonsson, Lilja Magnusdottir

    In geothermal power plants, the steam system is a costly component of the infrastructure in terms of construction requirements. The steam system consists of geothermal wells, well head equipment, pipelines and separators connecting wells to the separators and the separators to the power plant. This paper describes an approach for optimum design of a steam system, with focus on topology and route selection for pipelines transporting two-phase fluid from geothermal wells to a separation station and single-phase pipelines from the separator stations to the power plant. This article proposes a new approach for selecting the locations of the separators and power plant and routes for both two phase-flow and single-phase flow pipelines in a geothermal steam gathering system. Multiple weighted distance maps calculated by uniform cost Dijkstra’s algorithm are used to find the optimum location of a site for a steam separator based on the flow capacity of geothermal wells. The two-phase flow routes are monotonic and the incline is slight in order to minimize the pressure drop and the slug flow conditions in the pipeline. Once the location of separators has been optimized, the optimum location of the power plant can be determined based on the route selection for both the pipelines transporting steam to the power plant and the pipelines transporting the used geothermal fluid from the power plant to the injection wells. The objective is to minimize both cost and visual effects. A comparison of this method to traditional methods shows that when the method described in this paper is used, shorter routes and cheaper systems can be designed with less environmental impact.

  • Modelling and Analysis of a Horizontal Direct Chill Casting Process

    by Gardar Gardarsson, Throstur Gudmundsson, Magnus Th Jonsson, Halldor Palsson


  • Structural modeling of the casings in the IDDP-1 well: Load history analysis

    by Gunnar Skulason Kaldal, Magnus T. Jonsson, Halldor Palsson, Sigrun N. Karlsdottir


  • Structural modeling of the casings in high temperature geothermal wells

    by Gunnar Skulason Kaldal, Magnus T. Jonsson, Halldor Palsson, Sigrun N. Karlsdottir


  • Specified Maintenance of Steam Turbines in Geothermal Power Plants

    by Almar Gunnarsson, Ari Elisson, Magnus Jonsson, Runar Unnthorsson

    In a geothermal power plant the working fluid used to produce electricity is often wet steam composed of corrosives chemicals. In this situation, more frequent maintenance of the equipment is required. By constructing an overview for maintenance in geothermal power plants and how it can be done with minimum power outages and cost, the geothermal energy can be made more competitive in comparison to other energy resources. This work is constructed as a part of a project, which has the aim of mapping the maintenance management system at the Hellisheiði geothermal power plant in Iceland. The object of the project is to establish Reliability Centered Maintenance (RCM) program for Hellisheiði power plant that can be utilized to establish efficient maintenance management procedures. The focus of this paper is to examine the steam turbines, which have been defined as one of the main subsystems of the power plant at Hellisheiði. A close look will be taken at the maintenance needed for the steam turbines by studying for example which parts break down and how frequently they fail. The local ability of the staff to repair or construct turbine parts on-site is explored. The paper explores how the maintenance and condition monitoring is carried out today and what can be improved in order to reduce cost. The data collected is analyzed using Failure Mode and Effect Analysis (FMEA) in order to get an overview of the system and to help organizing maintenance and condition monitoring of the power plant in the future. Furthermore, the paper presents an overview of currently employed maintenance methods at Hellisheiði power plant, the domestic ability for maintaining and repairing steam turbines and the power plant’s need for repairs. The results show that the need for maintenance of the geothermal steam turbines at Hellisheiði power plant is high and that on-site maintenance and repairs can decrease the cost.


  • Open Access

    Thermoelectric-Based Power Generator for Powering Microcontroller Based Security Camera

    by Robert Dell, Runar Unnthorsson, C. S. Wei, George W. Sidebotham, Magnus Thor Jonsson, William Foley, Eric Ginzburg, Subashis Paul, Seyoon Kim, Anthony Morris

    This paper presents the design, implementation and evaluation of a thermoelectric-based point of use power generation system with no moving parts. The power system was designed to be robust and stable, capable of being clamped onto the outer wall of a hot steam pipe with a temperature of over 160°C using only heat pipes and natural convection of ambient air for cooling. Several systems were built and tested. One system was built and tested at the Cooper Union in New York City. The power generation was evaluated for different ambient and steam pipe temperatures. The other systems were attached to an 85°C geothermal hot water pipe and a 100–120°C geothermal steam pipe in Iceland. The Cooper Union system was used to power two microcontroller based security cameras, one with wireless LAN and another with cellular connectivity. Additional testing of the PV voltage controller and the generator were conducted in Iceland. The results show that the system can be used to power surveillance systems, even in remote locations without access to the electrical grid. Because the system does not require grid access, it will run constantly, and hence improve security. Furthermore, the unit’s power generation is greater in colder environments that substantially degrade battery performance.


  • Numerical modelling of temperature fluctuations in superchilled fish loins packaged in expanded polystyrene and stored at dynamic temperature conditions

    by Björn Margeirsson, Halldór Pálsson, Viktor Popov, Radovan Gospavic, Sigurjón Arason, Kolbrún Sveinsdóttir, Magnús Þór Jónsson


  • Temperature fluctuations and quality deterioration of chilled cod (Gadus morhua) fillets packaged in different boxes stored on pallets under dynamic temperature conditions

    by Björn Margeirsson, Hélène L. Lauzon, Halldór Pálsson, Viktor Popov, Radovan Gospavic, Magnús Þór Jónsson, Sjöfn Sigurgísladóttir, Sigurjón Arason