S. Meijer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
S. Meijer has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
E. Gulski
High-voltage Components and Power Systems, Delft University of Technology, PO Box 5031, 2600 GA Delft, Netherlands
2 shared publicationsJ.J. Smit
Delft Univ. of Technol., Netherlands
2 shared publicationsL. Lamballais
Prysmian Cables and Systems B.V., P.O. Box 495, 2600 AL Delft, Netherlands
2 shared publicationsP.P. Seitz
Seitz Instruments AG, CH-5443 Niederrohrdorf, Switzerland
2 shared publicationsT.J.W.H. Hermans
Prysmian Cables and Systems B.V., P.O. Box 495, 2600 AL Delft, Netherlands
2 shared publicationsA. Girodet
Areva T&D, Villeurbanne Cedex, France
1 shared publication
Latest Publications
- 1 July 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 15535282,p. 544-547
VHF Partial Discharge Detection during After-Laying testing of Power Cables
In this paper the results of after-laying testing of transmission power cable accessories using a non-conventional technique are being presented. The non-conventional system is based on the detection of high frequency signals being emitted by the partial discharge. Therefore, each power cable accessory is equipped with either an internal or external sensor to decouple the partial discharge signals. The partial discharge detection system uses narrow-band detector, in this case a spectrum analyzer. This technique however is very difficult to calibrate due to different factors affecting the frequency response of the measuring setup. This paper also presents a sensitivity check which can be used to validate the sensitivity of the system for a certain required PD level. Examples of on-site sensitivity verification are presented, before the actual PD measurements take place. An example of this system is shown taken from several measurements performed in the field.
- 1 July 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 15535282,p. 544-547
VHF Partial Discharge Detection during After-Laying testing of Power Cables
In this paper the results of after-laying testing of transmission power cable accessories using a non-conventional technique are being presented. The non-conventional system is based on the detection of high frequency signals being emitted by the partial discharge. Therefore, each power cable accessory is equipped with either an internal or external sensor to decouple the partial discharge signals. The partial discharge detection system uses narrow-band detector, in this case a spectrum analyzer. This technique however is very difficult to calibrate due to different factors affecting the frequency response of the measuring setup. This paper also presents a sensitivity check which can be used to validate the sensitivity of the system for a certain required PD level. Examples of on-site sensitivity verification are presented, before the actual PD measurements take place. An example of this system is shown taken from several measurements performed in the field.
- 4 October 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
Transfer impedance measurement of electricity cables
The transfer impedance of cables is a parameter that can be used to compare the quality of cables. It is intended to determine if this parameter can also be used as a tool to calculate the differential mode voltages in a cable longer than a wavelength developed by common mode currents which are a result of electromagnetic radiation of disturbance sources. A plan is presented in which the steps are defined that are undertaken to obtain this result. The measurement setup that is used to measure the transfer impedance of mains network cables is described. This setup is tested and validated and the results of the first measurements are presented.
- 4 October 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
Transfer impedance measurement of electricity cables
The transfer impedance of cables is a parameter that can be used to compare the quality of cables. It is intended to determine if this parameter can also be used as a tool to calculate the differential mode voltages in a cable longer than a wavelength developed by common mode currents which are a result of electromagnetic radiation of disturbance sources. A plan is presented in which the steps are defined that are undertaken to obtain this result. The measurement setup that is used to measure the transfer impedance of mains network cables is described. This setup is tested and validated and the results of the first measurements are presented.
- 1 June 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21609225,p. 687-690
Advanced Partial Discharge Measuring System for Simultaneous Testing of Cable Accessories
In this paper measuring results of partial discharges in power cable accessories are described. For the purpose of measuring simultaneously partial discharge activity in three or more accessories during an acceptance test, a wireless partial discharge detection system was developed. Therefore, each power cable accessory is equipped with either an internal or external sensor to decouple the partial discharge signals. The system uses narrow-band detection and is described in this paper. The computers controlling the measuring units are connected via a wireless network which allows communication between the different units and the main computer situated at the voltage source site. Moreover, effective real time noise-suppression is possible by tuning the system to a noise-free frequency band. Practical examples of this system are shown based on several measurements performed in the field
- 1 June 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21609225,p. 687-690
Advanced Partial Discharge Measuring System for Simultaneous Testing of Cable Accessories
In this paper measuring results of partial discharges in power cable accessories are described. For the purpose of measuring simultaneously partial discharge activity in three or more accessories during an acceptance test, a wireless partial discharge detection system was developed. Therefore, each power cable accessory is equipped with either an internal or external sensor to decouple the partial discharge signals. The system uses narrow-band detection and is described in this paper. The computers controlling the measuring units are connected via a wireless network which allows communication between the different units and the main computer situated at the voltage source site. Moreover, effective real time noise-suppression is possible by tuning the system to a noise-free frequency band. Practical examples of this system are shown based on several measurements performed in the field
- 1 June 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21609225,p. 653-656
Comparison of the Breakdown Strength of N2, CO2 and SF6 using the Extended Up-and-Down Method
Nowadays in gas insulated systems (GIS), SF6 is often used as insulating medium. Due to the fact that SF6 is a greenhouse gas with a very high global warming potential (GWP), alternatives have been searched for over the last years. In particular, SF6/N2 gas mixtures have been extensively investigated for the use in gas insulated lines (GIL) and is being used in several applications. However, in these cases SF6 is still part of the insulating gas and the search for alternatives continues. In this respect, nitrogen (N2) and carbon dioxide (CO2) are interesting alternatives. In this paper, investigations into the breakdown strength of these gases will be described. Both gases were investigated in a plane-plane configuration, with a distance of 10 mm between the planes. The gas pressure was varied in steps of 2 bar, from 7 to 11 bar. To get to the 5% breakdown value under positive and negative lightning as well as switching impulses, the extended up-and-down method was applied and will be discussed in the paper. The results are compared to 3 and 4 bar SF6 to get the required data that can be used for design purposes
- 1 June 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21609225,p. 653-656
Comparison of the Breakdown Strength of N2, CO2 and SF6 using the Extended Up-and-Down Method
Nowadays in gas insulated systems (GIS), SF6 is often used as insulating medium. Due to the fact that SF6 is a greenhouse gas with a very high global warming potential (GWP), alternatives have been searched for over the last years. In particular, SF6/N2 gas mixtures have been extensively investigated for the use in gas insulated lines (GIL) and is being used in several applications. However, in these cases SF6 is still part of the insulating gas and the search for alternatives continues. In this respect, nitrogen (N2) and carbon dioxide (CO2) are interesting alternatives. In this paper, investigations into the breakdown strength of these gases will be described. Both gases were investigated in a plane-plane configuration, with a distance of 10 mm between the planes. The gas pressure was varied in steps of 2 bar, from 7 to 11 bar. To get to the 5% breakdown value under positive and negative lightning as well as switching impulses, the extended up-and-down method was applied and will be discussed in the paper. The results are compared to 3 and 4 bar SF6 to get the required data that can be used for design purposes