Andrzej Skalski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Andrzej Skalski has a total of 130 co-authors. Here are the top co-authors by number of shared publications:
- Marek Wodzinski
AGH University of Krakow
19 shared publications - Janusz Gajda
Department of Measurement and Electronics, AGH University of Krakow, Al. A. Mickiewicza 30, 30-059 Krakow, Poland
10 shared publications - Maciej Stanuch
MedApp S.A., 30-150 Krakow, Poland
8 shared publications Piotr Kedzierawski
Holycross Cancer Center, Department of Radiotherapy, Kielce, Poland
7 shared publicationsTomasz Kuszewski
Holycross Cancer Center, Department of Medical Physics, Kielce, Poland
7 shared publications- Daria Panek
AGH University of Science and Technology, Department of Measurement and Electronics, al. Mickiewicza 30, 30-059 Kraków, Poland
4 shared publications
Latest Publications
- Open Access
- 20 April 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Mixed reality navigation system for ultrasound-guided and fusion biopsies using markerless instrument tracking
Percutaneous needle biopsy is commonly performed under ultrasound guidance to visualize the target lesion and monitor needle position. This study aims to improve spatial information for the operator by accurately visualizing the ultrasound image at its true anatomical location and scale within a head-mounted display, co-registered with pre-procedural imaging data. Current mixed reality systems rely on fiducial markers to track the instruments, which limits their practical utility in clinical settings; therefore, this study evaluated a custom markerless method for ultrasound probe tracking that achieved accuracy suitable for clinical applications. By displaying the ultrasound image relative to the probe’s spatial position, the system enables seamless fusion with pre-procedural imaging data. Combined with markerless needle tracking, this approach provides a complete navigation solution. Target registration error analysis between 2D ultrasound and 3D computed tomography demonstrated a 95% likelihood that the error remains within 3.41 mm. A biopsy navigation assessment test confirmed the system’s strong potential to reduce the number of puncture attempts compared to conventional ultrasound guidance alone. By providing comprehensive spatial and imaging information, the navigation system may contribute to reduced operator error and improved procedural success rates.
- 20 April 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessMixed reality navigation system for ultrasound-guided and fusion biopsies using markerless instrument tracking
Percutaneous needle biopsy is commonly performed under ultrasound guidance to visualize the target lesion and monitor needle position. This study aims to improve spatial information for the operator by accurately visualizing the ultrasound image at its true anatomical location and scale within a head-mounted display, co-registered with pre-procedural imaging data. Current mixed reality systems rely on fiducial markers to track the instruments, which limits their practical utility in clinical settings; therefore, this study evaluated a custom markerless method for ultrasound probe tracking that achieved accuracy suitable for clinical applications. By displaying the ultrasound image relative to the probe’s spatial position, the system enables seamless fusion with pre-procedural imaging data. Combined with markerless needle tracking, this approach provides a complete navigation solution. Target registration error analysis between 2D ultrasound and 3D computed tomography demonstrated a 95% likelihood that the error remains within 3.41 mm. A biopsy navigation assessment test confirmed the system’s strong potential to reduce the number of puncture attempts compared to conventional ultrasound guidance alone. By providing comprehensive spatial and imaging information, the navigation system may contribute to reduced operator error and improved procedural success rates.
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 45 (5) , 2212-2228
Benchmark of Segmentation Techniques for Pelvic Fracture in CT and X-Ray: Summary of the PENGWIN 2024 Challenge
The segmentation of pelvic fracture fragments in CT and X-ray images is crucial for trauma diagnosis, surgical planning, and intraoperative guidance. However, accurately and efficiently delineating the bone fragments remains a significant challenge due to complex anatomy and imaging limitations. The PENGWIN challenge, organized as a MICCAI 2024 satellite event, aimed to advance automated fracture segmentation by benchmarking state-of-the-art algorithms on these complex tasks. A diverse dataset of 150 CT scans was collected from multiple clinical centers, and a large set of simulated X-ray images was generated using the DeepDRR method. Final submissions from 16 teams worldwide were evaluated under a rigorous multi-metric testing scheme. The top-performing CT algorithm achieved an average fragment-wise intersection over union (IoU) of 0.930, demonstrating satisfactory accuracy. However, in the X-ray task, the best algorithm achieved an IoU of 0.774, which is promising but not yet sufficient for intra-operative decision-making, reflecting the inherent challenges of fragment overlap in projection imaging. Beyond the quantitative evaluation, the challenge revealed methodological diversity in algorithm design. Variations in instance representation, such as primary-secondary classification versus boundary-core separation, led to differing segmentation strategies. Despite promising results, the challenge also exposed inherent uncertainties in fragment definition, particularly in cases of incomplete fractures. These findings suggest that interactive segmentation approaches, integrating human decision-making with task-relevant information, may be essential for improving model reliability and clinical applicability.
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 45 (5) , 2212-2228
Benchmark of Segmentation Techniques for Pelvic Fracture in CT and X-Ray: Summary of the PENGWIN 2024 Challenge
The segmentation of pelvic fracture fragments in CT and X-ray images is crucial for trauma diagnosis, surgical planning, and intraoperative guidance. However, accurately and efficiently delineating the bone fragments remains a significant challenge due to complex anatomy and imaging limitations. The PENGWIN challenge, organized as a MICCAI 2024 satellite event, aimed to advance automated fracture segmentation by benchmarking state-of-the-art algorithms on these complex tasks. A diverse dataset of 150 CT scans was collected from multiple clinical centers, and a large set of simulated X-ray images was generated using the DeepDRR method. Final submissions from 16 teams worldwide were evaluated under a rigorous multi-metric testing scheme. The top-performing CT algorithm achieved an average fragment-wise intersection over union (IoU) of 0.930, demonstrating satisfactory accuracy. However, in the X-ray task, the best algorithm achieved an IoU of 0.774, which is promising but not yet sufficient for intra-operative decision-making, reflecting the inherent challenges of fragment overlap in projection imaging. Beyond the quantitative evaluation, the challenge revealed methodological diversity in algorithm design. Variations in instance representation, such as primary-secondary classification versus boundary-core separation, led to differing segmentation strategies. Despite promising results, the challenge also exposed inherent uncertainties in fragment definition, particularly in cases of incomplete fractures. These findings suggest that interactive segmentation approaches, integrating human decision-making with task-relevant information, may be essential for improving model reliability and clinical applicability.
- Open Access
- 29 August 2025
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 272, 109037
DECODE: An open-source cloud-based platform for the noninvasive management of peripheral artery disease
- 29 August 2025
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 272, 109037
Open AccessDECODE: An open-source cloud-based platform for the noninvasive management of peripheral artery disease
- Open Access
- 19 August 2025
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 112
Automated segmentation of peripheral arteries in 3D CT data based on a Single-Depth vascular network
- 19 August 2025
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 112
Open AccessAutomated segmentation of peripheral arteries in 3D CT data based on a Single-Depth vascular network
- 1 January 2025
- Published by AGH University Press
- p. 87-110
Segmentacja aorty z obrazów tomografii komputerowej przy użyciu głębokich sieci neuronowych
The manuscript proposes employing the nnU-Net architecture for the segmentation of the aorta from computed tomography images. Preprocessing involved transforming various value ranges to align with the Hounsfield unit scale, in addition to implementing a windowing procedure. During the network training phase, a five-fold cross-validation protocol was utilized, resulting in the training of five models, whose predictions on the test set were aggregated. The models achieved an average Dice coefficient of 0.921 and an Intersection over Union of 0.858, signifying high prediction quality. The value of the Hausdorff distance indicated the presence of outliers, while the analysis of three-dimensional reconstructions highlighted regions of diminished segmentation accuracy.
- 1 January 2025
- Published by AGH University Press
- p. 87-110
Segmentacja aorty z obrazów tomografii komputerowej przy użyciu głębokich sieci neuronowych
The manuscript proposes employing the nnU-Net architecture for the segmentation of the aorta from computed tomography images. Preprocessing involved transforming various value ranges to align with the Hounsfield unit scale, in addition to implementing a windowing procedure. During the network training phase, a five-fold cross-validation protocol was utilized, resulting in the training of five models, whose predictions on the test set were aggregated. The models achieved an average Dice coefficient of 0.921 and an Intersection over Union of 0.858, signifying high prediction quality. The value of the Hausdorff distance indicated the presence of outliers, while the analysis of three-dimensional reconstructions highlighted regions of diminished segmentation accuracy.
- Open Access
Vessel Geometry Estimation for Patients with Peripheral Artery Disease
The estimation of vessels’ centerlines is a critical step in assessing the geometry of the vessel, the topological representation of the vessel tree, and vascular network visualization. In this research, we present a novel method for obtaining geometric parameters from peripheral arteries in 3D medical binary volumes. Our approach focuses on centerline extraction, which yields smooth and robust results. The procedure starts with a segmented 3D binary volume, from which a distance map is generated using the Euclidean distance transform. Subsequently, a skeleton is extracted, and seed points and endpoints are identified. A search methodology is used to derive the best path on the skeletonized 3D binary array while tracking from the goal points to the seed point. We use the distance transform to calculate the distance between voxels and the nearest vessel surface, while also addressing bifurcations when vessels divide into multiple branches. The proposed method was evaluated on 22 real cases and 10 synthetically generated vessels. We compared our method to different state-of-the-art approaches and demonstrated its better performance. The proposed method achieved an average error of 1.382 mm with real patient data and 0.571 mm with synthetic data, both of which are lower than the errors obtained by other state-of-the-art methodologies. This extraction of the centerline facilitates the estimation of multiple geometric parameters of vessels, including radius, curvature, and length.
Open AccessVessel Geometry Estimation for Patients with Peripheral Artery Disease
The estimation of vessels’ centerlines is a critical step in assessing the geometry of the vessel, the topological representation of the vessel tree, and vascular network visualization. In this research, we present a novel method for obtaining geometric parameters from peripheral arteries in 3D medical binary volumes. Our approach focuses on centerline extraction, which yields smooth and robust results. The procedure starts with a segmented 3D binary volume, from which a distance map is generated using the Euclidean distance transform. Subsequently, a skeleton is extracted, and seed points and endpoints are identified. A search methodology is used to derive the best path on the skeletonized 3D binary array while tracking from the goal points to the seed point. We use the distance transform to calculate the distance between voxels and the nearest vessel surface, while also addressing bifurcations when vessels divide into multiple branches. The proposed method was evaluated on 22 real cases and 10 synthetically generated vessels. We compared our method to different state-of-the-art approaches and demonstrated its better performance. The proposed method achieved an average error of 1.382 mm with real patient data and 0.571 mm with synthetic data, both of which are lower than the errors obtained by other state-of-the-art methodologies. This extraction of the centerline facilitates the estimation of multiple geometric parameters of vessels, including radius, curvature, and length.
- Open Access
Mixed Reality Biopsy Navigation System Utilizing Markerless Needle Tracking and Imaging Data Superimposition
Exact biopsy planning and careful execution of needle injection is crucial to ensure successful procedure completion as initially intended while minimizing the risk of complications. This study introduces a solution aimed at helping the operator navigate to precisely position the needle in a previously planned trajectory utilizing a mixed reality headset. A markerless needle tracking method was developed by integrating deep learning and deterministic computer vision techniques. The system is based on superimposing imaging data onto the patient’s body in order to directly perceive the anatomy and determine a path from the selected injection site to the target location. Four types of tests were conducted to assess the system’s performance: measuring the accuracy of needle pose estimation, determining the distance between injection sites and designated targets, evaluating the efficiency of material collection, and comparing procedure time and number of punctures required with and without the system. These tests, involving both phantoms and physician participation in the latter two, demonstrated the accuracy and usability of the proposed solution. The results showcased a significant improvement, with a reduction in number of punctures needed to reach the target location. The test was successfully completed on the first attempt in 70% of cases, as opposed to only 20% without the system. Additionally, there was a 53% reduction in procedure time, validating the effectiveness of the system.
Open AccessMixed Reality Biopsy Navigation System Utilizing Markerless Needle Tracking and Imaging Data Superimposition
Exact biopsy planning and careful execution of needle injection is crucial to ensure successful procedure completion as initially intended while minimizing the risk of complications. This study introduces a solution aimed at helping the operator navigate to precisely position the needle in a previously planned trajectory utilizing a mixed reality headset. A markerless needle tracking method was developed by integrating deep learning and deterministic computer vision techniques. The system is based on superimposing imaging data onto the patient’s body in order to directly perceive the anatomy and determine a path from the selected injection site to the target location. Four types of tests were conducted to assess the system’s performance: measuring the accuracy of needle pose estimation, determining the distance between injection sites and designated targets, evaluating the efficiency of material collection, and comparing procedure time and number of punctures required with and without the system. These tests, involving both phantoms and physician participation in the latter two, demonstrated the accuracy and usability of the proposed solution. The results showcased a significant improvement, with a reduction in number of punctures needed to reach the target location. The test was successfully completed on the first attempt in 70% of cases, as opposed to only 20% without the system. Additionally, there was a 53% reduction in procedure time, validating the effectiveness of the system.
- Open Access
DRU-Net: Pulmonary Artery Segmentation via Dense Residual U-Network with Hybrid Loss Function
The structure and topology of the pulmonary arteries is crucial to understand, plan, and conduct medical treatment in the thorax area. Due to the complex anatomy of the pulmonary vessels, it is not easy to distinguish between the arteries and veins. The pulmonary arteries have a complex structure with an irregular shape and adjacent tissues, which makes automatic segmentation a challenging task. A deep neural network is required to segment the topological structure of the pulmonary artery. Therefore, in this study, a Dense Residual U-Net with a hybrid loss function is proposed. The network is trained on augmented Computed Tomography volumes to improve the performance of the network and prevent overfitting. Moreover, the hybrid loss function is implemented to improve the performance of the network. The results show an improvement in the Dice and HD95 scores over state-of-the-art techniques. The average scores achieved for the Dice and HD95 scores are 0.8775 and 4.2624 mm, respectively. The proposed method will support physicians in the challenging task of preoperative planning of thoracic surgery, where the correct assessment of the arteries is crucial.
Open AccessDRU-Net: Pulmonary Artery Segmentation via Dense Residual U-Network with Hybrid Loss Function
The structure and topology of the pulmonary arteries is crucial to understand, plan, and conduct medical treatment in the thorax area. Due to the complex anatomy of the pulmonary vessels, it is not easy to distinguish between the arteries and veins. The pulmonary arteries have a complex structure with an irregular shape and adjacent tissues, which makes automatic segmentation a challenging task. A deep neural network is required to segment the topological structure of the pulmonary artery. Therefore, in this study, a Dense Residual U-Net with a hybrid loss function is proposed. The network is trained on augmented Computed Tomography volumes to improve the performance of the network and prevent overfitting. Moreover, the hybrid loss function is implemented to improve the performance of the network. The results show an improvement in the Dice and HD95 scores over state-of-the-art techniques. The average scores achieved for the Dice and HD95 scores are 0.8775 and 4.2624 mm, respectively. The proposed method will support physicians in the challenging task of preoperative planning of thoracic surgery, where the correct assessment of the arteries is crucial.
- Open Access
- 11 October 2022
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 226, 107173
Deep learning-based framework for automatic cranial defect reconstruction and implant modeling
- 11 October 2022
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 226, 107173
Open AccessDeep learning-based framework for automatic cranial defect reconstruction and implant modeling
- 1 January 2022
- Published by AGH University Press
- p. 129-144
Przetwarzanie, analiza i wizualizacja obrazów oraz sygnałów medycznych
- 1 January 2022
- Published by AGH University Press
- p. 129-144
Przetwarzanie, analiza i wizualizacja obrazów oraz sygnałów medycznych