RSR. Sussmann

R. Sussmann

*This is an algorithmically generated author record based on publicly available information.

R. Sussmann has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Technical Note: Interference errors in infrared remote sounding of the atmosphere

    by R. Sussmann, T. Borsdorff

    Classical error analysis in remote sounding distinguishes between four classes: "smoothing errors," "model parameter errors," "forward model errors," and "retrieval noise errors". For infrared sounding "interference errors", which, in general, cannot be described by these four terms, can be significant. Interference errors originate from spectral residuals due to "interfering species" whose spectral features overlap with the signatures of the target species. A general method for quantification of interference errors is presented, which covers all possible algorithmic implementations, i.e., fine-grid retrievals of the interfering species or coarse-grid retrievals, and cases where the interfering species are not retrieved. In classical retrieval setups interference errors can exceed smoothing errors and can vary by orders of magnitude due to state dependency. An optimum strategy is suggested which practically eliminates interference errors by systematically minimizing the regularization strength applied to joint profile retrieval of the interfering species. This leads to an interfering-species selective deweighting of the retrieval. Details of microwindow selection are no longer critical for this optimum retrieval and widened microwindows even lead to reduced overall (smoothing and interference) errors. Since computational power will increase, more and more operational algorithms will be able to utilize this optimum strategy in the future. The findings of this paper can be applied to soundings of all infrared-active atmospheric species, which include more than two dozen different gases relevant to climate and ozone. This holds for all kinds of infrared remote sounding systems, i.e., retrievals from ground-based, balloon-borne, airborne, or satellite spectroradiometers.


  • Open Access

    Stratospheric and tropospheric NO2 variability on the diurnal and annual scale: a combined retrieval from ENVISAT/SCIAMACHY and solar FTIR at the Permanent Ground-Truthing Facility Zugspitze/Garmisch

    by R. Sussmann, W. Stremme, J. P. Burrows, A. Richter, W. Seiler, M. Rettinger

    Columnar NO2 retrievals from solar FTIR measurements at the Zugspitze (47.42° N, 10.98° E, 2964 m a.s.l.), Germany were investigated synergistically with columnar NO2 retrieved from SCIAMACHY data by the University of Bremen scientific algorithm UB1.5 for the time span July 2002-October 2004. A new concept to match FTIR data to the time of satellite overpass makes use of the NO2 daytime increasing rate retrieved from the FTIR data set itself [+1.02(6)E+14 cm-2/h]. This measured increasing rate shows no significant seasonal variation. SCIAMACHY data within a 200-km radius around Zugspitze were considered, and a pollution-clearing scheme was developed to select only pixels corresponding to clean background (free) tropospheric conditions, and exclude local pollution hot spots. The resulting difference between SCIAMACHY and FTIR columns (without correcting for the different sensitivities of the instruments) varies between 0.60-1.24E+15 cm-2 with an average of 0.83E+15 cm-2. A day-to-day scatter of daily means of ≈7-10% could be retrieved in mutual agreement from FTIR and SCIAMACHY. Both data sets are showing sufficient precisions to make this assessment. Analysis of the averaging kernels gives proof that at high-mountain-site FTIR is a highly accurate measure for the pure stratospheric column, while SCIAMACHY shows significant tropospheric sensitivity. Based on this finding, we set up a combined a posteriori FTIR-SCIAMACHY retrieval for tropospheric NO2, based upon the averaging kernels. It yields an annual cycle of the clean background (free) tropospheric column (-2, an average of 1.09E+15 cm-2, and an intermediate phase between that of the well known boundary layer and stratospheric annual cycles. The outcome is a concept for an integrated global observing system for tropospheric NO2 that comprises DOAS nadir satellite measurements and a set of latitudinally distributed mountain-site or clean-air FTIR stations.


  • Open Access

    Validation of ENVISAT/SCIAMACHY columnar methane by solar FTIR spectrometry at the Ground-Truthing Station Zugspitze

    by R. Sussmann, W. Stremme, M. Buchwitz, R. de Beek

    Methane total-vertical column retrievals from ground-based solar FTIR measurements at the Permanent Ground-Truthing Station Zugspitze (47.42° N, 10.98° E, 2964m a.s.l.), Germany are used to validate column averaged methane retrieved from ENVISAT/SCIAMACHY spectra by WFM-DOAS (WFMD) version 0.4 and 0.41 for 153 days in 2003. Smoothing errors are estimated to be below 0.10% for FTIR and 0.14% for SCIAMACHY-WFMD retrievals and can be neglected for the assessment of observed bias and day-to-day-scatter. In order to minimize the altitude-difference effect, dry-air column averaged mixing ratios (XCH4) have been utilized. From the FTIR-time series of XCH4 an atmospheric day-to-day variability of 1% was found, and a sinusoidal annual cycle with a ≈1.6% amplitude. To obtain the WFMD bias, a polynomial fitted to the FTIR series was used as a reference. The result is WFMD v0.4/FTIR=1.008±0.019 and WFMD v0.41/FTIR=1.058±0.008. WFMD v0.41 was significantly improved by a time-dependent bias correction. It can still not capture the natural day-to-day variability, i.e., the standard deviation calculated from the daily-mean values is 2.4% using averages within a 2000-km radius, and 2.7% for a 1000-km radius. These numbers are dominated by a residual time-dependent bias in the order of 3%/month. The latter can be reduced, e.g., from 2.4% to 1.6% as shown by an empirical time-dependent bias correction. Standard deviations of the daily means, calculated from the individual measurements of each day, are excluding time-dependent biases, thus showing the potential precision of WFMD daily means, i.e., 0.3% for a 2000-km selection radius, and 0.6% for a 1000-km selection radius. Therefore, the annual cycle as well as possibly the day-to-day variability could be captured under the prerequisite of further advanced time-dependent bias corrections, or the use of other channels, where the icing issue is less prominent.


  • Open Access

    Initial validation of ENVISAT/SCIAMACHY columnar CO by FTIR profile retrievals at the Ground-Truthing Station Zugspitze

    by R. Sussmann, M. Buchwitz

    Carbon monoxide vertical profile retrievals from ground-based solar FTIR measurements at the Permanent Ground-Truthing Station Zugspitze (47.42° N, 10.98° E, 2964m a.s.l.), Germany are used to validate columnar CO retrieved from ENVISAT/SCIAMACHY spectra (WFM-DOAS version 0.4). The WFM-DOAS retrievals of CO include an empirical column scaling factor of 0.5. Therefore, not absolute column levels are validated, but the proper response of the SCIAMACHY retrievals to the atmospheric inter-annual variability is quantitatively assessed in comparison to the Zugspitze FTIR results. Although CO WFM-DOAS data for only 33 days were available for this study (data covering January-October 2003), it is possible to retrieve information on the CO annual cycle (≈10% amplitude) in a statistically significant fit out of the scatter of the SCIAMACHY WFM-DOAS data. To obtain this, all pixels within a minimum radius of 2000km around Zugspitze had to be averaged for each day.