RTRoger J. Tait

Roger J. Tait

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Roger J. Tait has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • High Performance Medical Image Registration Using a Distributed Blackboard Architecture

    by Roger J. Tait, Gerald Schaefer, Adrian A. Hopgood, Tomoharu Nakashima

    A major drawback of medical image registration techniques is the performance bottleneck associated with similarity computation. Such bottlenecks limit registration applications in situations where fast execution times are required. In this paper a novel framework for high performance intensity-based medical image registration is presented. Geometric alignment of both reference and sensed images is achieved through a combination of scaling, translation, and rotation. Crucially, similarity computation is performed intelligently by knowledge sources (KSs) organised in a worker/manager model. The KSs work in parallel and communicate with each other by means of a distributed blackboard architecture. Partitioning of the blackboard is used to balance communication and processing workloads. The registration framework presented demonstrates the flexibility of the coarse-grained parallelism employed and shows how high performance medical image registration can be achieved with non-specialised architectures. Experimental results obtained during testing show that substantial speedups can be achieved


  • Efficient 3-D Medical Image Registration Using a Distributed Blackboard Architecture

    by Roger J. Tait, Gerald Schaefer, Adrian A. Hopgood, Shao Ying Zhu

    A major drawback of 3-D medical image registration techniques is the performance bottleneck associated with re-sampling and similarity computation. Such bottlenecks limit registration applications in clinical situations where fast execution times are required and become particularly apparent in the case of registering 3-D data sets. In this paper a novel framework for high performance intensity-based volume registration is presented. Geometric alignment of both reference and sensed volume sets is achieved through a combination of scaling, translation, and rotation. Crucially, resampling and similarity computation is performed intelligently by a set of knowledge sources. The knowledge sources work in parallel and communicate with each other by means of a distributed blackboard architecture. Partitioning of the blackboard is used to balance communication and processing workloads. Large-scale registrations with substantial speedups, when compared with a conventional implementation, have been demonstrated


  • Overlay of thermal and visual medical images using skin detection and image registration

    by Gerald Schaefer, Roger Tait, Shao Ying Zhu

    Thermography captures the temperature distribution of the human skin and is employed in various medical applications. Often it is useful to cross-reference the resulting thermograms with visual images of the patient, either to see which part of the anatomy is affected by a certain disease or to judge the efficacy of the treatment. An attractive approach to provide this information is to overlay the two image types and show a composite image to the clinician. Producing such an overlay however is a non-trivial task due to differences in image capturing conditions of the two modalities. In this paper we introduce an approach that produces accurate overlays of thermal and visual medical images. First unnecessary background information of the visual part are removed by an image segmentation step based on skin detection. The thermal image is then aligned through an intensity based image registration technique. Experimental results based on an set of visual-thermal image pairs demonstrate the effectiveness of the proposed approach


  • Efficient 3-D Medical Image Registration Using a Distributed Blackboard Architecture

    by Roger J. Tait, Gerald Schaefer, Adrian A. Hopgood, Shao Ying Zhu

    A major drawback of 3-D medical image registration techniques is the performance bottleneck associated with re-sampling and similarity computation. Such bottlenecks limit registration applications in clinical situations where fast execution times are required and become particularly apparent in the case of registering 3-D data sets. In this paper a novel framework for high performance intensity-based volume registration is presented. Geometric alignment of both reference and sensed volume sets is achieved through a combination of scaling, translation, and rotation. Crucially, resampling and similarity computation is performed intelligently by a set of knowledge sources. The knowledge sources work in parallel and communicate with each other by means of a distributed blackboard architecture. Partitioning of the blackboard is used to balance communication and processing workloads. Large-scale registrations with substantial speedups, when compared with a conventional implementation, have been demonstrated

  • Overlay of thermal and visual medical images using skin detection and image registration

    by Gerald Schaefer, Roger Tait, Shao Ying Zhu

    Thermography captures the temperature distribution of the human skin and is employed in various medical applications. Often it is useful to cross-reference the resulting thermograms with visual images of the patient, either to see which part of the anatomy is affected by a certain disease or to judge the efficacy of the treatment. An attractive approach to provide this information is to overlay the two image types and show a composite image to the clinician. Producing such an overlay however is a non-trivial task due to differences in image capturing conditions of the two modalities. In this paper we introduce an approach that produces accurate overlays of thermal and visual medical images. First unnecessary background information of the visual part are removed by an image segmentation step based on skin detection. The thermal image is then aligned through an intensity based image registration technique. Experimental results based on an set of visual-thermal image pairs demonstrate the effectiveness of the proposed approach