Holger Holst
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Holger Holst has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Lars Edenbrandt
Lund University
2 shared publications - Mattias Ohlsson
Lund University 6 Department of Earth and Environmental Sciences Lund, Sweden
2 shared publications Anders Heyden
Department of Mathematics, Lund Institute of Technology, Lund, Sweden
1 shared publicationAndreas Järund
Department of Clinical Physiology, Lund University, Lund, Sweden
1 shared publicationEva Evander
Department of Clinical Physiology, Lund University, Lund, Sweden
1 shared publicationFrederik Kahl
Department of Mathematics, Lund Institute of Technology, Lund, Sweden
1 shared publication
Latest Publications
- 7 April 2000
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 27 (4) , 400-406
Automated interpretation of ventilation-perfusion lung scintigrams for the diagnosis of pulmonary embolism using artificial neural networks
The purpose of this study was to develop a completely automated method for the interpretation of ventilation-perfusion (V-P) lung scintigrams used in the diagnosis of pulmonary embolism. An artificial neural network was trained for the diagnosis of pulmonary embolism using 18 automatically obtained features from each set of V-P scintigrams. The techniques used to process the images included their alignment to templates, the construction of quotient images based on the ventilation and perfusion images, and the calculation of measures describing V-P mismatches in the quotient images. The templates represented lungs of normal size and shape without any pathological changes. Images that could not be properly aligned to the templates were detected and excluded automatically. After exclusion of those V-P scintigrams not properly aligned to the templates, 478 V-P scintigrams remained in a training group of consecutive patients with suspected pulmonary embolism, and a further 87 V-P scintigrams formed a separate test group comprising patients who had undergone pulmonary angiography. The performance of the neural network, measured as the area under the receiver operating characteristic curve, was 0.87 (95% confidence limits 0.82–0.92) in the training group and 0.79 (0.69–0.88) in the test group. It is concluded that a completely automated method can be used for the interpretation of V-P scintigrams. The performance of this method is similar to others previously presented, whereby features were extracted manually.
- 7 April 2000
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 27 (4) , 400-406
Automated interpretation of ventilation-perfusion lung scintigrams for the diagnosis of pulmonary embolism using artificial neural networks
The purpose of this study was to develop a completely automated method for the interpretation of ventilation-perfusion (V-P) lung scintigrams used in the diagnosis of pulmonary embolism. An artificial neural network was trained for the diagnosis of pulmonary embolism using 18 automatically obtained features from each set of V-P scintigrams. The techniques used to process the images included their alignment to templates, the construction of quotient images based on the ventilation and perfusion images, and the calculation of measures describing V-P mismatches in the quotient images. The templates represented lungs of normal size and shape without any pathological changes. Images that could not be properly aligned to the templates were detected and excluded automatically. After exclusion of those V-P scintigrams not properly aligned to the templates, 478 V-P scintigrams remained in a training group of consecutive patients with suspected pulmonary embolism, and a further 87 V-P scintigrams formed a separate test group comprising patients who had undergone pulmonary angiography. The performance of the neural network, measured as the area under the receiver operating characteristic curve, was 0.87 (95% confidence limits 0.82–0.92) in the training group and 0.79 (0.69–0.88) in the test group. It is concluded that a completely automated method can be used for the interpretation of V-P scintigrams. The performance of this method is similar to others previously presented, whereby features were extracted manually.
- 1 January 2000
- Published by Springer Nature
- p. 209-214
Acute Myocardial Infarction: Analysis of the ECG Using Artificial Neural Networks
- 1 January 2000
- Published by Springer Nature
- p. 209-214
Acute Myocardial Infarction: Analysis of the ECG Using Artificial Neural Networks
- 1 January 2000
- Published by Springer Nature
- p. 186-191
A New Artificial Neural Network Method for the Interpretation of ECGs
- 1 January 2000
- Published by Springer Nature
- p. 186-191
A New Artificial Neural Network Method for the Interpretation of ECGs