    Alarms in the intensive care unit: how can the number of false alarms be reduced?

    by Marie-Christine Chambrin

    Many alarms, as they now exist in most monitoring systems, are not usually perceived as helpful by the medical staff because of the high incidence of false alarms. This paper gives an overview of the problems related to their current design and the objectives of monitoring. The current approaches used to improve the situation are then presented from two main standpoints: organizational and behavioural on the one hand, and technical on the other.


  • Multicentric study of monitoring alarms in the adult intensive care unit (ICU): a descriptive analysis

    by M.-C. Chambrin, P. Ravaux, D. Calvelo-Aros, A. Jaborska, C. Chopin, B. Boniface

    Objectives: To assess the relevance of current monitoring alarms as a warning system in the adult ICU. Design: Prospective, observational study. Settings: Two university hospital, and three general hospital, ICUs. Patients: Hundred thirty-one patients, ventilated at admission, from different shifts (morning, evening, night) combined with different stages of stay, early (0–3 days), intermediate (4–6 days) and late (> 6 days). Interventions: Experienced nurses were asked to record the patient's characteristics and, for each alarm event, the reason, type and consequence. Measurements and main results: The mean age of the patients included was 59.8 ± 16.4 and SAPS1 was 15.9 ± 7.4. We recorded 1971 h of care. The shift distribution was 78 mornings, 85 evenings and 83 nights; the stage distribution was 88 early, 78 intermediate and 80 late. There were 3188 alarms, an average of one alarm every 37 min: 23.7 % were due to staff manipulation, 17.5 % to technical problems and 58.8 % to the patients. Alarms originated from ventilators (37.8 %), cardiovascular monitors (32.7 %), pulse oximeters (14.9 %) and capnography (13.5 %). Of the alarms, 25.8 % had a consequence such as sensor repositioning, suction, modification of the therapy (drug or ventilation). Only 5.9 % of the alarms led to a physician's being called. The positive predictive value of an alarm was 27 % and its negative predictive value was 99 %. The sensitivity was 97 % and the specificity 58 %. Conclusions: The study confirms that the level of monitoring in ICUs generates a great number of false-positive alarms.