Poching DeLaurentis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Poching DeLaurentis has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Yuehwern Yih
Purdue University, West Lafayette, IN, USA
4 shared publications Kang-Yu Hsu
Purdue Univ, Regenstrief Ctr Healthcare Engn, Gerald D & Edna E Mann Hall,Suite 225, W Lafayette, IN 47907 USA
3 shared publications- Yuval Bitan
Ben-Gurion University of the Negev
3 shared publications - Denny Yu
Edwardson School of Industrial Engineering, Purdue University, West Lafayette, USA
2 shared publications Andrew C Fritschle
Eskenazi Health, Indianapolis, IN
1 shared publication- Ayten Turkcan
Department of Mechanical and Industrial Engineering, Northeastern University, 360 Huntington Avenue, 334 Snell Engineering, Boston, MA, 02115, USA.
1 shared publication
Latest Publications
- 1 October 2022
- Published by Springer Nature
- p. 125-143
Smart Technologies in Healthcare: Overview of Human Factors and Infusion Pumps
- 1 October 2022
- Published by Springer Nature
- p. 125-143
Smart Technologies in Healthcare: Overview of Human Factors and Infusion Pumps
- 26 May 2021
- Published by Georg Thieme Verlag KG in Applied Clinical Informatics
- Vol. 12 (03) , 528-538
Quantifying the Impact of Infusion Alerts and Alarms on Nursing Workflows: A Retrospective Analysis
Background Smart infusion pumps affect workflows as they add alerts and alarms in an information-rich clinical environment where alarm fatigue is already a major concern. An analytic approach is needed to quantify the impact of these alerts and alarms on nursing workflows and patient safety. Objectives To analyze a detailed infusion dataset from a smart infusion pump system and identify contributing factors for infusion programming alerts, operational alarms, and alarm resolution times. Methods We analyzed detailed infusion pump data across four hospitals in a health system for up to 1 year. The prevalence of alerts and alarms was grouped by infusion type and a selected list of 32 high-alert medications (HAMs). Logistic regression was used to explore the relationship between a set of risk factors and the occurrence of alerts and alarms. We used nonparametric tests to explore the relationship between alarm resolution times and a subset of predictor variables. Results The study dataset included 745,641 unique infusions with a total of 3,231,300 infusion events. Overall, 28.7% of all unique infusions had at least one operational alarm, and 2.1% of all unique infusions had at least one programming alert. Alarms averaged two per infusion, whereas at least one alert happened in every 48 unique infusions. Eight percent of alarms took over 4 minutes to resolve. Intravenous fluid infusions had the highest rate of error-state occurrence. HAMs had 1.64 more odds for alerts than the rest of the infusions. On average, HAMs had a higher alert rate than maintenance fluids. Conclusion Infusion pump alerts and alarms impact clinical care, as alerts and alarms by design interrupt clinical workflow. Our study showcases how hospital system leadership teams can leverage infusion pump informatics to prioritize quality improvement and patient safety initiatives pertaining to infusion practices.
- 26 May 2021
- Published by Georg Thieme Verlag KG in Applied Clinical Informatics
- Vol. 12 (03) , 528-538
Quantifying the Impact of Infusion Alerts and Alarms on Nursing Workflows: A Retrospective Analysis
Background Smart infusion pumps affect workflows as they add alerts and alarms in an information-rich clinical environment where alarm fatigue is already a major concern. An analytic approach is needed to quantify the impact of these alerts and alarms on nursing workflows and patient safety. Objectives To analyze a detailed infusion dataset from a smart infusion pump system and identify contributing factors for infusion programming alerts, operational alarms, and alarm resolution times. Methods We analyzed detailed infusion pump data across four hospitals in a health system for up to 1 year. The prevalence of alerts and alarms was grouped by infusion type and a selected list of 32 high-alert medications (HAMs). Logistic regression was used to explore the relationship between a set of risk factors and the occurrence of alerts and alarms. We used nonparametric tests to explore the relationship between alarm resolution times and a subset of predictor variables. Results The study dataset included 745,641 unique infusions with a total of 3,231,300 infusion events. Overall, 28.7% of all unique infusions had at least one operational alarm, and 2.1% of all unique infusions had at least one programming alert. Alarms averaged two per infusion, whereas at least one alert happened in every 48 unique infusions. Eight percent of alarms took over 4 minutes to resolve. Intravenous fluid infusions had the highest rate of error-state occurrence. HAMs had 1.64 more odds for alerts than the rest of the infusions. On average, HAMs had a higher alert rate than maintenance fluids. Conclusion Infusion pump alerts and alarms impact clinical care, as alerts and alarms by design interrupt clinical workflow. Our study showcases how hospital system leadership teams can leverage infusion pump informatics to prioritize quality improvement and patient safety initiatives pertaining to infusion practices.
- 20 July 2019
- Published by Oxford University Press (OUP) in American Journal of Health-System Pharmacy
- Vol. 76 (17) , 1281-1287
Stakeholder perceptions of smart infusion pumps and drug library updates: A multisite, interdisciplinary study
Purpose: Results of a questionnaire-based study to evaluate smart infusion pump end users’ perceptions and understanding of the drug library update process are reported. Methods: The Indianapolis Coalition for Patient Safety, Inc., in partnership with the Regenstrief Center for Healthcare Engineering, conducted a 33-item electronic, cross-sectional survey across 5 Indiana health systems from May through November 2017. Interdisciplinary participants identified for survey distribution included nurses, pharmacists, biomedical engineers, administrators, and medication safety officers. The survey assessed the following domains: patient safety, the drug library update process, knowledge of drug libraries and the update process, and end-user perceptions. Results: A total of 778 submitted surveys were included in the data analysis, with a large majority of responses (90.2%) provided by nurses. The use of drug libraries for ensuring patient safety was deemed extremely important or important by 88% of respondents, but 36% indicated that they were unsure of whether drug libraries are updated on a routine basis in their health system. Approximately two-thirds agreed that the current update process improves quality of care (65.0%) and patient safety (68.1%). Moreover, 53.3% agreed that the current drug library update process was effective. However, less than 10% responded correctly when asked about the steps required to update the drug library. Furthermore, only 18% correctly indicated that when a pump is on it may not necessarily contain the most up-to-date version of the drug library. Conclusion: A survey of 5 health systems in Indianapolis identified several end-user knowledge gaps related to smart pump drug library updates. The results suggest that these gaps were most likely due to a combination of the 2-step update process and the fact that the current drug library version is not easy to find and/or user-friendly and it is unclear when an update is pending.
- 20 July 2019
- Published by Oxford University Press (OUP) in American Journal of Health-System Pharmacy
- Vol. 76 (17) , 1281-1287
Stakeholder perceptions of smart infusion pumps and drug library updates: A multisite, interdisciplinary study
Purpose: Results of a questionnaire-based study to evaluate smart infusion pump end users’ perceptions and understanding of the drug library update process are reported. Methods: The Indianapolis Coalition for Patient Safety, Inc., in partnership with the Regenstrief Center for Healthcare Engineering, conducted a 33-item electronic, cross-sectional survey across 5 Indiana health systems from May through November 2017. Interdisciplinary participants identified for survey distribution included nurses, pharmacists, biomedical engineers, administrators, and medication safety officers. The survey assessed the following domains: patient safety, the drug library update process, knowledge of drug libraries and the update process, and end-user perceptions. Results: A total of 778 submitted surveys were included in the data analysis, with a large majority of responses (90.2%) provided by nurses. The use of drug libraries for ensuring patient safety was deemed extremely important or important by 88% of respondents, but 36% indicated that they were unsure of whether drug libraries are updated on a routine basis in their health system. Approximately two-thirds agreed that the current update process improves quality of care (65.0%) and patient safety (68.1%). Moreover, 53.3% agreed that the current drug library update process was effective. However, less than 10% responded correctly when asked about the steps required to update the drug library. Furthermore, only 18% correctly indicated that when a pump is on it may not necessarily contain the most up-to-date version of the drug library. Conclusion: A survey of 5 health systems in Indianapolis identified several end-user knowledge gaps related to smart pump drug library updates. The results suggest that these gaps were most likely due to a combination of the 2-step update process and the fact that the current drug library version is not easy to find and/or user-friendly and it is unclear when an update is pending.
- 1 July 2019
- Published by Elsevier in Research in Social and Administrative Pharmacy
- Vol. 15 (7) , 889-894
High-alert medication administration and intravenous smart pumps: A descriptive analysis of clinical practice
- 1 July 2019
- Published by Elsevier in Research in Social and Administrative Pharmacy
- Vol. 15 (7) , 889-894
High-alert medication administration and intravenous smart pumps: A descriptive analysis of clinical practice
- 1 March 2019
- Published by Wolters Kluwer Health in Journal of Patient Safety
- Vol. 15 (1) , e8-e14
Unintended Patient Safety Risks Due to Wireless Smart Infusion Pump Library Update Delays
Our previous study showed that the issue of drug library update delays on wireless intravenous (IV) infusion pumps of one major vendor was widespread and significant. However, the impact of such a delay was unclear. The objective of this study was to quantify the impact of pump library update delays on patient safety in terms of missed and false infusion programming alerts. The study data sets included infusion logs and drug libraries from three hospitals of one health system from January 2015 to December 2016. We identified limit setting changes of any two consecutive drug library versions. We quantified the impact of using outdated drug limit settings by missed and false infusion programming alerts. Twenty-five updates of the drug library were released within the health system during the 2-year period with an average interval of 28.8 days. After a new library version was issued, it took at least 6 days for 50% of all pumps to become up-to-date and 15 days or more to reach 80%. All three hospitals had at least 16% of all IV infusions programmed with outdated libraries. This resulted in 18%, 24.4%, and 27% of false alerts in the three hospitals, respectively. We identified two cases of missed alert infusions of high-risk medications, propofol, and potassium chloride, which could have negatively impacted patient safety. These findings support our assumption that potential serious harm can happen when IV infusions are administered with outdated drug limit settings due to delays in drug library updates on the pump.
- 1 March 2019
- Published by Wolters Kluwer Health in Journal of Patient Safety
- Vol. 15 (1) , e8-e14
Unintended Patient Safety Risks Due to Wireless Smart Infusion Pump Library Update Delays
Our previous study showed that the issue of drug library update delays on wireless intravenous (IV) infusion pumps of one major vendor was widespread and significant. However, the impact of such a delay was unclear. The objective of this study was to quantify the impact of pump library update delays on patient safety in terms of missed and false infusion programming alerts. The study data sets included infusion logs and drug libraries from three hospitals of one health system from January 2015 to December 2016. We identified limit setting changes of any two consecutive drug library versions. We quantified the impact of using outdated drug limit settings by missed and false infusion programming alerts. Twenty-five updates of the drug library were released within the health system during the 2-year period with an average interval of 28.8 days. After a new library version was issued, it took at least 6 days for 50% of all pumps to become up-to-date and 15 days or more to reach 80%. All three hospitals had at least 16% of all IV infusions programmed with outdated libraries. This resulted in 18%, 24.4%, and 27% of false alerts in the three hospitals, respectively. We identified two cases of missed alert infusions of high-risk medications, propofol, and potassium chloride, which could have negatively impacted patient safety. These findings support our assumption that potential serious harm can happen when IV infusions are administered with outdated drug limit settings due to delays in drug library updates on the pump.
- 12 February 2019
- Published by Springer Nature in Journal of Medical Systems
- Vol. 43 (3) , 75
Tracking the Progress of Wireless Infusion Pump Drug Library Updates– A Data-Driven Analysis of Pump Update Delays
Modern smart infusion pumps are wirelessly connected to a network server for easy data communications. The two-way communication allows uploading of infusion data and downloading of drug library updates. We have discovered significant delays in library updates. This research aimed at studying the drug library update process of one vendor pump and the contributing factors of pump update delays. Our data included BD Alaris™ pump status and infusion reports of two hospital systems (92 and 80 days, respectively, in 2015). We analyzed drug library update progressions at the individual device and fleet levels. To complete a library update, a pump goes through two status transitions: from noncurrent to a new library pending, and from pending to current. On average it took five to nine days for 50% of a pump fleet to become current after a new drug library was disseminated. We confirmed factors that affect noncurrent-to-pending time to include time to first power-on and total power-on time. We also found that high pump utilization promotes shorter pending-to-current time. Two distinctive and important steps of a drug library update on Alaris™ pumps are pending a new library and completing the library installation. To avoid potential patient harm caused by infusion pumps without appropriate drug limits due to update delays, hospitals should monitor the progression of a drug library update on its pump fleet. Potential ways to improve drug library updates on a fleet of pumps include better technologies, improved pump user-interface design, and more staff training.
- 12 February 2019
- Published by Springer Nature in Journal of Medical Systems
- Vol. 43 (3) , 75
Tracking the Progress of Wireless Infusion Pump Drug Library Updates– A Data-Driven Analysis of Pump Update Delays
Modern smart infusion pumps are wirelessly connected to a network server for easy data communications. The two-way communication allows uploading of infusion data and downloading of drug library updates. We have discovered significant delays in library updates. This research aimed at studying the drug library update process of one vendor pump and the contributing factors of pump update delays. Our data included BD Alaris™ pump status and infusion reports of two hospital systems (92 and 80 days, respectively, in 2015). We analyzed drug library update progressions at the individual device and fleet levels. To complete a library update, a pump goes through two status transitions: from noncurrent to a new library pending, and from pending to current. On average it took five to nine days for 50% of a pump fleet to become current after a new drug library was disseminated. We confirmed factors that affect noncurrent-to-pending time to include time to first power-on and total power-on time. We also found that high pump utilization promotes shorter pending-to-current time. Two distinctive and important steps of a drug library update on Alaris™ pumps are pending a new library and completing the library installation. To avoid potential patient harm caused by infusion pumps without appropriate drug limits due to update delays, hospitals should monitor the progression of a drug library update on its pump fleet. Potential ways to improve drug library updates on a fleet of pumps include better technologies, improved pump user-interface design, and more staff training.
- 1 August 2018
- Published by Oxford University Press (OUP) in American Journal of Health-System Pharmacy
- Vol. 75 (15) , 1140-1144
Prevalence of wireless smart-pump drug library update delays
Purpose Results of a study to estimate the prevalence and severity of delays in wireless updates of smart-pump drug libraries across a large group of U.S. hospitals are reported. Methods A prolonged smart-pump drug library update may result in patient harm if a pump is programmed with an incorrect limit setting at the time of drug administration. A retrospective study was conducted using smart-pump alert data extracted from the Regenstrief National Center for Medical Device Informatics (REMEDI) database. The study sample consisted of 49 hospitals in 5 states across the Midwest and Kentucky operated by 12 health systems; all the facilities used a specific brand of smart pump (BD Alaris, Beckton, Dickinson and Company) capable of generating alert data and had consistently contributed alert data to the REMEDI database over a 2-year period. An update delay was defined as the interval from the time a drug library version was replaced to the time of the last infusion alert triggered by the previous version during the study period. Results Of the 12 health systems, 11 were found to have had drug library update delays during the study period, with delay medians ranging from 22 to 192 days. The overall delay minimum and maximum durations were 0 and 661 days. Conclusion Substantial delays in completion of wireless updates of smart-pump drug libraries were common across a group of hospitals of various sizes.
- 1 August 2018
- Published by Oxford University Press (OUP) in American Journal of Health-System Pharmacy
- Vol. 75 (15) , 1140-1144
Prevalence of wireless smart-pump drug library update delays
Purpose Results of a study to estimate the prevalence and severity of delays in wireless updates of smart-pump drug libraries across a large group of U.S. hospitals are reported. Methods A prolonged smart-pump drug library update may result in patient harm if a pump is programmed with an incorrect limit setting at the time of drug administration. A retrospective study was conducted using smart-pump alert data extracted from the Regenstrief National Center for Medical Device Informatics (REMEDI) database. The study sample consisted of 49 hospitals in 5 states across the Midwest and Kentucky operated by 12 health systems; all the facilities used a specific brand of smart pump (BD Alaris, Beckton, Dickinson and Company) capable of generating alert data and had consistently contributed alert data to the REMEDI database over a 2-year period. An update delay was defined as the interval from the time a drug library version was replaced to the time of the last infusion alert triggered by the previous version during the study period. Results Of the 12 health systems, 11 were found to have had drug library update delays during the study period, with delay medians ranging from 22 to 192 days. The overall delay minimum and maximum durations were 0 and 661 days. Conclusion Substantial delays in completion of wireless updates of smart-pump drug libraries were common across a group of hospitals of various sizes.