JKJai Kulkarni

Jai Kulkarni

*This is an algorithmically generated author record based on publicly available information.

Jai Kulkarni has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Fluctuating residual limb volume accommodated with an adjustable, modular socket design

    by Kay Mitton, Jai Kulkarni, Kenneth William Dunn, Anthony Hoang Ung

    This novel case report describes the problems of prescribing a prosthetic socket in a left transfemoral amputee secondary to chronic patellofemoral instability compounded by complex regional pain syndrome. Following the amputation, complex regional pain syndrome symptoms recurred in the residual limb, presenting mainly with oedema. Due to extreme daily volume fluctuations of the residual limb, a conventional, laminated thermoplastic socket fitting was not feasible. An adjustable, modular socket design was trialled. The residual limb volume fluctuations were accommodated within the socket. Amputee rehabilitation could be continued, and the rehabilitation goals were achieved. The patient was able to wear the prosthesis for 8 h daily and to walk unaided indoors and outdoors. An adjustable, modular socket design accommodated the daily residual limb volume fluctuations and provided a successful outcome in this case. It demonstrates the complexities of socket fitting and design with volume fluctuations. Ongoing complex regional pain syndrome symptoms within the residual limb can lead to fitting difficulties in a conventional, laminated thermoplastic socket due to volume fluctuations. An adjustable, modular socket design can accommodate this and provide a successful outcome.


  • Bariatric amputee

    by Jai Kulkarni, Dominic P Hannett, Steven Purcell

    This study reviewed prevalence of patients with lower limb amputations with above normal weight profile, with body mass index over 25, in seven disablement services centres managing their amputee rehabilitation in the United Kingdom. To review two clinical standards of practice in amputee rehabilitation. Ambulant lower limb amputees should have their body weight recorded on an electronic information system, with identification of cohort with body weight >100 kg. Lower limb amputees to be provided with suitable weight-rated prosthesis. Observational study of clinical practice. Data were collected from the Clinical Information Management Systems. Inclusion criteria – subjects were ambulant prosthetic users with some prosthetic intervention in the last 5 years and had at least one lower limb amputation. In 96% of patients, the weight record profile was maintained. In addition, 86% were under 100 kg, which is the most common weight limit of prosthetic componentry. Of 15,204 amputation levels, there were 1830 transfemoral and transtibial sites in users with body weight over 100 kg. In 60 cases, the prosthetic limb build was rated to be below the user body weight. In 96% of our patients, body weight was documented, and in 97%, the prosthetic limb builds were within stated body weight limits, but this may not be the case in all the other disablement services centres in the United Kingdom. Also, the incidence of obesity in the United Kingdom is a growing problem, and the health issues associated with obesity are further compounded in the amputee population. Prosthetic componentry has distinct weight limits which must be considered during prescription. As people with amputation approach the limits of specific components, clinicians are faced with the challenge of continued provision in a safe and suitable manner. This article reviews the amputee population and the current national profile to consider trends in provision and the incidence of these challenges.


  • Open Access

    Visuomotor behaviours when using a myoelectric prosthesis

    by Mohammad M D Sobuh, Laurence P J Kenney, Adam J Galpin, Sibylle B Thies, Jane McLaughlin, Jai Kulkarni, Peter Kyberd

    A recent study showed that the gaze patterns of amputee users of myoelectric prostheses differ markedly from those seen in anatomically intact subjects. Gaze behaviour is a promising outcome measures for prosthesis designers, as it appears to reflect the strategies adopted by amputees to compensate for the absence of proprioceptive feedback and uncertainty/delays in the control system, factors believed to be central to the difficulty in using prostheses. The primary aim of our study was to characterise visuomotor behaviours over learning to use a trans-radial myoelectric prosthesis. Secondly, as there are logistical advantages to using anatomically intact subjects in prosthesis evaluation studies, we investigated similarities in visuomotor behaviours between anatomically intact users of a trans-radial prosthesis simulator and experienced trans-radial myoelectric prosthesis users.


  • Open Access

    Walking speed related joint kinetic alterations in trans-tibial amputees: impact of hydraulic 'ankle’ damping

    by Alan R De Asha, Ramesh Munjal, Jai Kulkarni, John G Buckley

    Background: Passive prosthetic devices are set up to provide optimal function at customary walking speed and thus may function less effectively at other speeds. This partly explains why joint kinetic adaptations become more apparent in lower-limb amputees when walking at speeds other than customary. The present study determined whether a trans-tibial prosthesis incorporating a dynamic-response foot that was attached to the shank via an articulating hydraulic device (hy A-F) lessened speed-related adaptations in joint kinetics compared to when the foot was attached via a rigid, non-articulating attachment (rig F). Methods: Eight active unilateral trans-tibial amputees completed walking trials at their customary walking speed, and at speeds they deemed to be slow-comfortable and fast-comfortable whilst using each type of foot attachment. Moments and powers at the distal end of the prosthetic shank and at the intact joints of both limbs were compared between attachment conditions. Results: There was no change in the amount of intact-limb ankle work across speed or attachment conditions. As speed level increased there was an increase on both limbs in the amount of hip and knee joint work done, and increases on the prosthetic side were greater when using the hy A-F. However, because all walking speed levels were higher when using the hy A-F, the intact-limb ankle and combined joints work per meter travelled were significantly lower; particularly so at the customary speed level. This was the case despite the hy A-F dissipating more energy during stance. In addition, the amount of eccentric work done per meter travelled became increased at the residual knee when using the hy A-F, with increases again greatest at customary speed. Conclusions: Findings indicate that a trans-tibial prosthesis incorporating a dynamic-response foot reduced speed-related changes in compensatory intact-limb joint kinetics when the foot was attached via an articulating hydraulic device compared to rigid attachment. As differences between attachment conditions were greatest at customary speed, findings indicate a hydraulic ankle-foot device is most effectual at the speed it is set-up for.


  • Open Access

    Role of myofascial trigger points in post-amputation pain

    by Finn Reiestad, Jai Kulkarni

    Post-amputation pain is a multifactorial issue and thus necessitates multiple treatment strategies. Myofascial trigger points-related pain remains under diagnosed and hence not addressed. This study investigates causation and management. To identify the presence and role of myofascial trigger points in post amputation pain. Post-amputation pain clinic review and recruitment. Twenty one identified patients in the post-amputation pain clinic with myofascial trigger points were recruited, of which 13 were transtibial and eight transfemoral and all had phantom limb pain and stump pain. The trigger points were identified and injected with long-acting local anaesthetic on a weekly basis and patients were followed up on an ongoing basis. There was significant resolution of pain on the Visual Analogue Scale in the majority of these patients within five weeks, though some of the transtibial cohort needed further eight injections on a weekly basis for resolution of the pain. Identification of myofascial trigger points in amputation stumps and their role in post-amputation pain, followed by appropriate intervention is an important facet of management of this complex chronic pain. Myofascial trigger points in amputation stumps can lead to ongoing chronic post-amputation pain and our results indicate that identification and intervention of these trigger points does lead to notable resolution of this pain.