Zhengfeng Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zhengfeng Li has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Bin Li
Zhongyuan University of Technology, Zhengzhou 450007, China
1 shared publication Changchun Zhao
School of Mechatronics Engineering, Zhongyuan University of Technology, Zhengzhou, China
1 shared publicationDonglin Zhu
College of Mathematics and Computer Science, Zhejiang Normal University, Jinhua, China
1 shared publication- Dongxu Ren
Zhongyuan University of Technology
1 shared publication Guohui Zhang
School of Management Engineering, Zhengzhou University of Aeronautics, Zhengzhou, China
1 shared publication- Hang Xu
Beijing Engineering Research Center of Precision Measurement Technology and Instruments, College of Mechanical Engineering and Applied Electronics Technology, Beijing University of Technology, Beijing 100124, China
1 shared publication
Latest Publications
- 29 November 2023
- Published by Springer Nature in Cluster Computing
- Vol. 27 (4) , 4605-4619
Multi-strategy improved sparrow search algorithm for job shop scheduling problem
- 29 November 2023
- Published by Springer Nature in Cluster Computing
- Vol. 27 (4) , 4605-4619
Multi-strategy improved sparrow search algorithm for job shop scheduling problem
- Open Access
- 15 November 2017
- Published by MDPI AG in Proceedings
- Vol. 2 (3) , 101
The Alignment Method for Linear Scale Projection Lithography Based on CCD Image Analysis
This paper presents a method to improve the alignment accuracy of mask in linear scale projection lithography, in which the adjacent pixel gray square variance method of CCD image is used to find the best position of the focal length of the motherboard and then realize the alignment of the focal plane. Two image positions in the focal plane from the CCD are compared the traits overlap through the image splicing principle, and to establish the correction of four typical errors on the basis of the whole grating errors. At the same time, using the rotation error of the mask to summarize Grayscale Variation Function of CCD Image, and threshold functions are used to express the factors including wave crests of the amplitude, period error and phase error, which govern the rotation accuracy and weight alignment accuracy expression of the four error factors is established. In the experiment, it is finally corrected the slope of the mask and be adjusted the same direction of the slide plate with the help of dual-frequency laser interferometer, the influence of alignment error on lithography accuracy was discussed and verified in the static case and the CCD maximum resolution pixel corresponds to 0.1 μm, the accuracy of scale is 0.79 μm in only 200 mm measurement range.
- 15 November 2017
- Published by MDPI AG in Proceedings
- Vol. 2 (3) , 101
Open AccessThe Alignment Method for Linear Scale Projection Lithography Based on CCD Image Analysis
This paper presents a method to improve the alignment accuracy of mask in linear scale projection lithography, in which the adjacent pixel gray square variance method of CCD image is used to find the best position of the focal length of the motherboard and then realize the alignment of the focal plane. Two image positions in the focal plane from the CCD are compared the traits overlap through the image splicing principle, and to establish the correction of four typical errors on the basis of the whole grating errors. At the same time, using the rotation error of the mask to summarize Grayscale Variation Function of CCD Image, and threshold functions are used to express the factors including wave crests of the amplitude, period error and phase error, which govern the rotation accuracy and weight alignment accuracy expression of the four error factors is established. In the experiment, it is finally corrected the slope of the mask and be adjusted the same direction of the slide plate with the help of dual-frequency laser interferometer, the influence of alignment error on lithography accuracy was discussed and verified in the static case and the CCD maximum resolution pixel corresponds to 0.1 μm, the accuracy of scale is 0.79 μm in only 200 mm measurement range.