MGMarco Abdo Gravina

Marco Abdo Gravina

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Marco Abdo Gravina has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    IMPACTO DA ESPESSURA DOS PROTETORES BUCAIS PERSONALIZADOS NA PREVENÇÃO DE TRAUMATISMOS OROFACIAIS

    by Pedro Elio Rocha Caniato, Marco Abdo Gravina, Sérgio Luiz Mota Júnior

    As lesões orofaciais configuram-se como agressões mecânicas, térmicas ou químicas aos dentes e às estruturas faciais, representando um importante problema de saúde pública. A prática esportiva, sobretudo em modalidades de contato, é um dos principais fatores etiológicos desses traumatismos. Diante desse cenário, o uso de protetores bucais destaca-se como medida preventiva eficaz, atuando na absorção e dissipação da energia gerada por impactos, o que reduz, significativamente, o risco de fraturas, luxações e outras injúrias dentárias. Entre os fatores que influenciam sua eficiência, a espessura do dispositivo é determinante, pois interfere diretamente em sua capacidade de absorção de choques, conforto e retenção. Evidências científicas demonstram que protetores personalizados com espessuras entre 3 e 4 mm proporcionam o melhor equilíbrio entre proteção e conforto, enquanto espessuras maiores, embora aumentem a segurança, podem comprometer a respiração e o desempenho do atleta. Além disso, avanços no design e na composição dos protetores, como o uso de estruturas multilaminadas e combinações de materiais flexíveis e rígidos, têm ampliado sua eficácia na dissipação das forças de impacto. Conclui-se que a espessura ideal e o correto planejamento estrutural dos protetores bucais são fundamentais para otimizar sua função protetora, contribuindo de forma significativa para a prevenção de lesões orofaciais em atletas.

  • Open Access

    Shear bond resistance and enamel surface comparison after the bonding and debonding of ceramic and metallic brackets

    by José Maurício da Rocha, Marco Abdo Gravina, Marcio José da Silva Campos, Cátia Cardoso Abdo Quintão, Carlos Nelson Elias, Robert Willer Farinazzo Vitral

    OBJECTIVE: To evaluate, in vitro, the shear bond strength presented by three brands of polycrystalline ceramic brackets and one brand of metallic bracket; verify the adhesive remnant index (ARI) after the tests, and analyze, through scanning electron microscopy (SEM) the enamel surface topography after debonding, detecting the release of mineral particles. METHODS: Sixty bovine lower incisors were used. Three ceramic brackets (Allure(r), InVu(r), and Clarity(r)) and one metallic bracket (Geneus(r)) were bonded with Transbond XT(r). Kruskal-Wallis's test (significance level set at 5%) was applied to the results of share bond and ARI. Mann Whitney's test was performed to compare the pairs of brackets in relation to their ARI. Brown-Forsythe's test (significance level set at 5%) was applied to the results of enamel chemical composition. Comparisons between groups were made with Games-Howell's and the Post-hoc tests. RESULTS: No statistically significant difference was observed in relation to the shear bond strength loads. Clarity(r) brackets were the most affected in relation to the surface topography and to the release of mineral particles of enamel (calcium ions). CONCLUSION: With regard to the ARI, there was a prevalence of score 4 (40.4%). As for enamel surface topography, the Geneus(r) bracket was the only one which did not show superficial tissue loss. The InVu(r) and Clarity(r) ones showed cohesive fractures in 33.3% and the Allure(r) in 50%, the latter being the one that presented most fractures during removal.


  • Open Access

    Mechanical properties of NiTi and CuNiTi wires used in orthodontic treatment. Part 2: Microscopic surface appraisal and metallurgical characteristics

    by Marco Abdo Gravina, Cristiane Canavarro, Carlos Nelson Elias, Maria das Graças Afonso Miranda Chaves, Ione Helena Vieira Portella Brunharo, Cátia Cardoso Abdo Quintão

    OBJECTIVE: This research aimed at comparing the qualitative chemical compositions and the surface morphology of fracture regions of eight types of Nickel (Ni) Titanium (Ti) conventional wires, superelastic and heat-activated (GAC, TP, Ormco, Masel, Morelli and Unitek), to the wires with addition of copper (CuNiTi 27oC and 35oC, Ormco) after traction test. METHODS: The analyses were performed in a scanning electronic microscope (JEOL, model JSM-5800 LV) with EDS system of microanalysis (energy dispersive spectroscopy). RESULTS : The results showed that NiTi wires presented Ni and Ti as the main elements of the alloy with minimum differences in their composition. The CuNiTi wires, however, presented Ni and Ti with a significant percentage of copper (Cu). As for surface morphology, the wires that presented the lowest wire-surface roughness were the superelastic ones by Masel and Morelli, while those that presented the greatest wire-surface roughness were the CuNiTi 27oC and 35oC ones by Ormco, due to presence of microcavity formed as a result of pulling out some particles, possibly of NiTi. 4 The fracture surfaces presented characteristics of ductile fracture, with presence of microcavities. The superelastic wires by GAC and the CuNiTi 27oC and the heat-activated ones by Unitek presented the smallest microcavities and the lowest wire-surface roughness with regard to fracture, while the CuNiTi 35oC wires presented inadequate wire-surface roughness in the fracture region. CONCLUSION: CuNiTi 35oC wires did not present better morphologic characteristics in comparison to the other wires with regard to surfaces and fracture region.


  • Open Access

    Mechanical properties of NiTi and CuNiTi shape-memory wires used in orthodontic treatment. Part 1: stress-strain tests

    by Marco Abdo Gravina, Ione Helena Vieira Portella Brunharo, Cristiane Canavarro, Carlos Nelson Elias, Cátia Cardoso Abdo Quintão

    OBJECTIVE: This research aimed to compare, through traction tests, eight types of superelastic and heat-activated NiTi archwires, by six trade companies (GAC, TP, Ormco, Masel, Morelli and Unitek) to those with addition of copper (CuNiTi 27ºC and 35ºC, Ormco). METHODS: The tests were performed in an EMIC mechanical testing machine, model DL10000, capacity of 10 tons, at the Military Institute of Engineering (IME). RESULTS: The results showed that, generally, heat-activated NiTi archwires presented slighter deactivation loadings in relation to superelastic. Among the archwires that presented deactivation loadings biologically more adequate are the heat-activated by GAC and by Unitek. Among the superelastic NiTi, the CuNiTi 27ºC by Ormco were the ones that presented slighter deactivation loadings, being statistically (ANOVA) similar, to the ones presented by the heat-activated NiTi archwires by Unitek. When compared the CuNiTi 27ºC and 35ºC archwires, it was observed that the 27ºC presented deactivation forces of, nearly, ⅓ of the presented by the 35ºC. CONCLUSION: It was concluded that the CuNiTi 35ºC archwires presented deactivation loadings biologically less favorable in relation to the other heat-activated NiTi archwires, associated to lower percentage of deformation, on the constant baselines of deactivation, showing less adequate mechanical behavior, under traction, in relation to the other archwires.


  • Open Access

    Evaluation of the friction force generated by monocristalyne and policristalyne ceramic brackets in sliding mechanics

    by Roberta Ferreira Pimentel, Roberto Sotto Maior Fortes de Oliveira, Maria das Graças Afonso Miranda Chaves, Carlos Nelson Elias, Marco Abdo Gravina

    OBJECTIVE: To evaluate and compare "in vitro" the maximum friction force generated by three types of esthetic brackets, two types of polycrystalline conventional ceramic brackets (20/40 and InVu) and one type of sapphire monocrystalline bracket (Radiance) in dry and artificial saliva wet settings. Also, to evaluate the influence exerted by artificial saliva on the friction forces of those brackets. METHODS: Tests were performed in dry and artificial saliva wet setting (Oral Balance) by using an EMIC DL 10000 testing machine, simulating a 2 mm slide of 0.019 x 0.025-in rectangular stainless steel wires over the pre-angulated and pre-torqued (right superior canine, Roth prescription, slot 0.022 x 0.030-in) brackets (n = 18 for each bracket). In order to compare groups in dry and wet settings, the ANOVA was used. For comparisons related to the dry versus wet setting, the student t test was used for each group. RESULTS: The results showed that in the absence of saliva the Radiance monocrystalline brackets showed the highest friction coefficients, followed by the 20/40 and the InVu polycrystalline brackets. In tests with artificial saliva, the Radiance and the 20/40 brackets had statistically similar friction coefficients and both were greater than that presented by the InVu brackets. The artificial saliva did not change the maximum friction force of the Radiance brackets, but, for the others (20/40 and InVu), an increase of friction was observed in its presence. CONCLUSION: The InVu brackets showed, in the absence and in the presence of saliva, the lowest friction coefficient.