Thay Q. Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Thay Q. Lee has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
James E. Tibone
Department of Orthopaedic Surgery, Keck School of Medicine, University of Southern California, Los Angeles, CA, USA
4 shared publicationsMichelle H. McGarry
Orthopaedic Biomechanics Laboratory, VA Long Beach Healthcare System, 5901 East 7th. Street (09/151), Long Beach, CA, 90822, USA
4 shared publicationsLawrence Wang
Orthopaedic Biomechanics Laboratory, VA Long Beach Healthcare System (09/151), 5901 East 7th. Street, Long Beach, CA, 90822, USA
2 shared publicationsNathanael Heckmann
Department of Orthopaedic Surgery, Keck School of Medicine, University of Southern California, Los Angeles, CA, USA
2 shared publicationsBryan Hanypsiak
Department of Orthopaedic Surgery, Mount Sinai Hospital, New York, NY, USA
1 shared publicationCori Grantham
Department of Orthopaedic Surgery, Keck School of Medicine, University of Southern California, Los Angeles, CA, USA
1 shared publication
Latest Publications
- 24 December 2015
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 24 (2) , 533-539
The effect of defect orientation and size on glenohumeral instability: a biomechanical analysis
Purpose The purpose of this study was to determine the relationship between bony stability and percentage of anterior glenoid bone loss and the effect of bone loss orientation. Methods Twelve cadaveric shoulders were studied. Glenoid bone defects were simulated in two different osteotomy angles: 0° and 45° to the superoinferior (SI) axis of the glenoid. The force and displacement required for dislocation were measured under two compressive forces of 40 and 60N. Testing was performed for the intact glenoid and glenoid defects of 2, 4, 6, 8, and 10 mm from the anterior margin. Results The maximum force for dislocation with the 2-mm glenoid defect was significantly decreased compared with intact glenoid (p = 0.01), and this force also significantly decreased with each increase in defect size (p < 0.05). The dislocation force for 45° osteotomy was significantly higher than that for 0° osteotomy for all defect widths up to 8 mm with 40N compression and 6 mm with 60N compression (p < 0.001). The displacement at dislocation did not significantly decrease until the 8-mm defect with the 45° osteotomy but significantly decreased with the 4-mm defect with the 0° osteotomy. The required force for dislocation with 60N compression was significantly higher than that with 40N compression for all osteotomy sizes and orientations. Conclusions The decrease in stability even with glenoid bone loss as small as 2 mm or 7.5 % of the glenoid width suggests that bony restoration is recommended whenever any bone loss exists. Bone defects parallel to SI axis may be more susceptible to recurrent instability, and shoulder muscle strengthening exercises may increase glenohumeral compressive force and thus improve glenohumeral stability. Bony restoration is recommended whenever bone loss exists even with small bone fragments particularly those in line with the superior–inferior axis of the glenoid.
- 24 December 2015
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 24 (2) , 533-539
The effect of defect orientation and size on glenohumeral instability: a biomechanical analysis
Purpose The purpose of this study was to determine the relationship between bony stability and percentage of anterior glenoid bone loss and the effect of bone loss orientation. Methods Twelve cadaveric shoulders were studied. Glenoid bone defects were simulated in two different osteotomy angles: 0° and 45° to the superoinferior (SI) axis of the glenoid. The force and displacement required for dislocation were measured under two compressive forces of 40 and 60N. Testing was performed for the intact glenoid and glenoid defects of 2, 4, 6, 8, and 10 mm from the anterior margin. Results The maximum force for dislocation with the 2-mm glenoid defect was significantly decreased compared with intact glenoid (p = 0.01), and this force also significantly decreased with each increase in defect size (p < 0.05). The dislocation force for 45° osteotomy was significantly higher than that for 0° osteotomy for all defect widths up to 8 mm with 40N compression and 6 mm with 60N compression (p < 0.001). The displacement at dislocation did not significantly decrease until the 8-mm defect with the 45° osteotomy but significantly decreased with the 4-mm defect with the 0° osteotomy. The required force for dislocation with 60N compression was significantly higher than that with 40N compression for all osteotomy sizes and orientations. Conclusions The decrease in stability even with glenoid bone loss as small as 2 mm or 7.5 % of the glenoid width suggests that bony restoration is recommended whenever any bone loss exists. Bone defects parallel to SI axis may be more susceptible to recurrent instability, and shoulder muscle strengthening exercises may increase glenohumeral compressive force and thus improve glenohumeral stability. Bony restoration is recommended whenever bone loss exists even with small bone fragments particularly those in line with the superior–inferior axis of the glenoid.
- 24 December 2015
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 24 (2) , 489-495
Biomechanical comparison of the modified Bristow procedure with and without capsular repair
Purpose The Bristow procedure has become an effective surgical option for recurrent anterior instability of the shoulder; however, there is no consensus on whether a capsule repair following a Bristow procedure is necessary to restore glenohumeral stability. The purpose of this study was to evaluate whether capsular repair with a modified Bristow procedure affects rotational range of motion and glenohumeral stability. Methods Rotational range of motion, glenohumeral translation and kinematics were measured in eight cadaveric shoulders in 90° shoulder abduction in the scapular and coronal planes for four conditions: intact, 20 % bony Bankart lesion, modified Bristow without capsular repair and modified Bristow with capsular repair. Results Creation of the bony Bankart led to a significant increase in total range of motion and anterior–inferior translation compared to the intact shoulder. The modified Bristow procedure significantly decreased anterior–inferior translation compared to the bony Bankart but did not decrease total range of motion. Capsular repair decreased total range of motion in the scapular and coronal planes and altered normal glenohumeral kinematics in external rotation positions. Conclusion Repairing the capsule in a Bristow procedure decreases rotational range of motion yet does not offer any added anterior–inferior translational stability. Capsular repair also significantly alters normal glenohumeral kinematics. Capsule repair with a Bristow procedure may not add additional glenohumeral stability in positions of apprehension and may potentially over constrain the joint and cause altered kinematics.
- 24 December 2015
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 24 (2) , 489-495
Biomechanical comparison of the modified Bristow procedure with and without capsular repair
Purpose The Bristow procedure has become an effective surgical option for recurrent anterior instability of the shoulder; however, there is no consensus on whether a capsule repair following a Bristow procedure is necessary to restore glenohumeral stability. The purpose of this study was to evaluate whether capsular repair with a modified Bristow procedure affects rotational range of motion and glenohumeral stability. Methods Rotational range of motion, glenohumeral translation and kinematics were measured in eight cadaveric shoulders in 90° shoulder abduction in the scapular and coronal planes for four conditions: intact, 20 % bony Bankart lesion, modified Bristow without capsular repair and modified Bristow with capsular repair. Results Creation of the bony Bankart led to a significant increase in total range of motion and anterior–inferior translation compared to the intact shoulder. The modified Bristow procedure significantly decreased anterior–inferior translation compared to the bony Bankart but did not decrease total range of motion. Capsular repair decreased total range of motion in the scapular and coronal planes and altered normal glenohumeral kinematics in external rotation positions. Conclusion Repairing the capsule in a Bristow procedure decreases rotational range of motion yet does not offer any added anterior–inferior translational stability. Capsular repair also significantly alters normal glenohumeral kinematics. Capsule repair with a Bristow procedure may not add additional glenohumeral stability in positions of apprehension and may potentially over constrain the joint and cause altered kinematics.
- 26 September 2014
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 24 (6) , 1979-1987
The effect of long and short head biceps loading on glenohumeral joint rotational range of motion and humeral head position
Purpose: To evaluate the effect of loading the long and short heads of the biceps on glenohumeral range of motion and humeral head position.Methods: Eight cadaveric shoulders were tested in 60° abduction in the scapula and coronal plane. Muscle loading was applied based on cross‐sectional area ratios. The short and long head of the biceps were loaded individually followed by combined loading. Range of motion was measured with 2.2 Nm torque, and the humeral head apex position was measured using a MicroScribe. A paired t test with Bonferroni correction was used for statistics.Results: Long head loading decreased internal rotation in both the scapular (17.9 %) and coronal planes (5.7 %) and external rotation in the scapular plane (2.6 %) (P < 0.04). With only short head loading, maximum internal rotation was significantly increased in the scapular and coronal plane. Long head and short head loading shifted the humeral head apex posteriorly in maximum internal rotation in both planes with the long head shift being significantly greater than the short head. Long head loading also shifted the humeral apex inferiorly in internal rotation and inferiorly posteriorly in neutral rotation in the scapular plane. With the long head unloaded, there was a significant superior shift with short head loading in both planes.Conclusion: Loading the long head of the biceps had a much greater effect on glenohumeral range of motion and humeral head shift than the short head of the biceps; however, in the absence of long head loading, with the short head loaded, maximum internal rotation increases and the humeral head shifts superiorly, which may contribute to impingement following tenodesis of the long head of the biceps. These small changes in rotational range of motion and humeral head position with biceps tenodesis may not lead to pathologic conditions in low‐demand patients; however, in throwers, biceps tenodesis may lead to increased contact pressures in late‐cocking and deceleration that will likely translate to decreased performance therefore every effort should be made to preserve the biceps‐labral complex.
- 26 September 2014
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 24 (6) , 1979-1987
The effect of long and short head biceps loading on glenohumeral joint rotational range of motion and humeral head position
Purpose: To evaluate the effect of loading the long and short heads of the biceps on glenohumeral range of motion and humeral head position.Methods: Eight cadaveric shoulders were tested in 60° abduction in the scapula and coronal plane. Muscle loading was applied based on cross‐sectional area ratios. The short and long head of the biceps were loaded individually followed by combined loading. Range of motion was measured with 2.2 Nm torque, and the humeral head apex position was measured using a MicroScribe. A paired t test with Bonferroni correction was used for statistics.Results: Long head loading decreased internal rotation in both the scapular (17.9 %) and coronal planes (5.7 %) and external rotation in the scapular plane (2.6 %) (P < 0.04). With only short head loading, maximum internal rotation was significantly increased in the scapular and coronal plane. Long head and short head loading shifted the humeral head apex posteriorly in maximum internal rotation in both planes with the long head shift being significantly greater than the short head. Long head loading also shifted the humeral apex inferiorly in internal rotation and inferiorly posteriorly in neutral rotation in the scapular plane. With the long head unloaded, there was a significant superior shift with short head loading in both planes.Conclusion: Loading the long head of the biceps had a much greater effect on glenohumeral range of motion and humeral head shift than the short head of the biceps; however, in the absence of long head loading, with the short head loaded, maximum internal rotation increases and the humeral head shifts superiorly, which may contribute to impingement following tenodesis of the long head of the biceps. These small changes in rotational range of motion and humeral head position with biceps tenodesis may not lead to pathologic conditions in low‐demand patients; however, in throwers, biceps tenodesis may lead to increased contact pressures in late‐cocking and deceleration that will likely translate to decreased performance therefore every effort should be made to preserve the biceps‐labral complex.
- 30 July 2014
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 24 (6) , 1918-1924
A biomechanical assessment of a novel double endobutton technique versus a coracoid cerclage sling for acromioclavicular and coracoclavicular injuries
Purpose: Recently, many acromioclavicular–coracoclavicular (AC–CC) ligament reconstruction techniques address only the CC ligament. However, many of these techniques are costly, time‐consuming, and require the use of allogenic grafts, making them prone to creep and failure or novel devices making them challenging for orthopaedic surgeons. The purpose of this study was to compare the biomechanical characteristics of a double endobutton technique using a standard endobutton CL with those of a coracoid cerclage sling (CS) for reconstruction of the CC ligaments.Methods: Anterior–posterior (AP) translation and superior–inferior (SI) translation were quantified for eight matched pairs of intact AC joints. One shoulder from each pair underwent a double endobutton repair, using an endobutton CL modified with an additional endobutton (Smith & Nephew, Memphis, Tenn) and placed through holes in the coracoid and clavicle. The contra‐lateral shoulder received a coracoid sling reconstruction using an anterior tibialis tendon. Translation testing was repeated after reconstruction, followed by load‐to‐failure testing. Paired t tests were used for statistical analysis.Results: The CS technique demonstrated a greater SI and AP translation than the double endobutton technique (p < 0.05). Additionally, the double endobutton technique had a greater stiffness (40.2 ± 11.0 vs. 20.3 ± 6.4 N/mm, p = 0.005), yield load (168.5 ± 11.0 vs. 86.8 ± 22.9 N, p = 0.002), and ultimate load (504.4 ± 199.7 vs. 213.2 ± 103.4 N, p = 0.026) when compared to the CS technique.Conclusion: The double endobutton technique yielded less translation about the AC joint and displayed stronger load‐to‐failure characteristics than the CS reconstruction. As such, this technique may be better suited to restore native AC–CC biomechanics, reduce post‐operative pain, and prevent recurrent subluxation and dislocation than an allogenic graft construct. The double endobutton technique may be a suitable option for addressing AC–CC injuries.
- 30 July 2014
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 24 (6) , 1918-1924
A biomechanical assessment of a novel double endobutton technique versus a coracoid cerclage sling for acromioclavicular and coracoclavicular injuries
Purpose: Recently, many acromioclavicular–coracoclavicular (AC–CC) ligament reconstruction techniques address only the CC ligament. However, many of these techniques are costly, time‐consuming, and require the use of allogenic grafts, making them prone to creep and failure or novel devices making them challenging for orthopaedic surgeons. The purpose of this study was to compare the biomechanical characteristics of a double endobutton technique using a standard endobutton CL with those of a coracoid cerclage sling (CS) for reconstruction of the CC ligaments.Methods: Anterior–posterior (AP) translation and superior–inferior (SI) translation were quantified for eight matched pairs of intact AC joints. One shoulder from each pair underwent a double endobutton repair, using an endobutton CL modified with an additional endobutton (Smith & Nephew, Memphis, Tenn) and placed through holes in the coracoid and clavicle. The contra‐lateral shoulder received a coracoid sling reconstruction using an anterior tibialis tendon. Translation testing was repeated after reconstruction, followed by load‐to‐failure testing. Paired t tests were used for statistical analysis.Results: The CS technique demonstrated a greater SI and AP translation than the double endobutton technique (p < 0.05). Additionally, the double endobutton technique had a greater stiffness (40.2 ± 11.0 vs. 20.3 ± 6.4 N/mm, p = 0.005), yield load (168.5 ± 11.0 vs. 86.8 ± 22.9 N, p = 0.002), and ultimate load (504.4 ± 199.7 vs. 213.2 ± 103.4 N, p = 0.026) when compared to the CS technique.Conclusion: The double endobutton technique yielded less translation about the AC joint and displayed stronger load‐to‐failure characteristics than the CS reconstruction. As such, this technique may be better suited to restore native AC–CC biomechanics, reduce post‐operative pain, and prevent recurrent subluxation and dislocation than an allogenic graft construct. The double endobutton technique may be a suitable option for addressing AC–CC injuries.
- 10 June 2014
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 24 (2) , 585-592
The biomechanical effect of shoulder remplissage combined with Bankart repair for the treatment of engaging Hill–Sachs lesions
The purpose of this study was to determine the biomechanical effects of the remplissage repair combined with Bankart repair for engaging Hill–Sachs lesions on range of motion (ROM), translation, and glenohumeral kinematics. Six cadaveric shoulders were tested using a custom shoulder testing system. ROM, kinematics, and anterior–posterior (AP) and superior–inferior glenohumeral translations were quantified at 0° and 60° glenohumeral abduction. Six conditions were tested: intact, Bankart lesion, Bankart with 40 % Hill–Sachs lesion, Bankart repair, Bankart repair with remplissage, and remplissage repair alone. Humeral external rotation (ER) and total range of motion increased significantly after the creation of the Bankart lesion at both 0° and 60° abduction. The Bankart repair restored ER to intact values at 0° and 60° abduction, and the addition of the remplissage repair did not significantly alter range of motion from the Bankart repair alone. AP translation increased following the creation of the Bankart and Hill–Sachs lesions and was restored with the Bankart repair; the remplissage did not alter translation from the Bankart repair alone. At maximum ER at 60° abduction, the apex of the humeral head shifted posteriorly and inferiorly with remplissage repair. The addition of the remplissage procedure combined with Bankart repair for treatment of large Hill–Sachs lesions had no statistically significant effect on ROM or translation, but altered the kinematics of the glenohumeral joint. Thus, by addressing the humeral bone defect following an anterior shoulder dislocation, the remplissage technique with concurrent Bankart repair may be a relatively minimally invasive option for converting engaging Hill–Sachs lesions to non-engaging and promoting shoulder stability, though further biomechanical and clinical studies are warranted.
- 10 June 2014
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 24 (2) , 585-592
The biomechanical effect of shoulder remplissage combined with Bankart repair for the treatment of engaging Hill–Sachs lesions
The purpose of this study was to determine the biomechanical effects of the remplissage repair combined with Bankart repair for engaging Hill–Sachs lesions on range of motion (ROM), translation, and glenohumeral kinematics. Six cadaveric shoulders were tested using a custom shoulder testing system. ROM, kinematics, and anterior–posterior (AP) and superior–inferior glenohumeral translations were quantified at 0° and 60° glenohumeral abduction. Six conditions were tested: intact, Bankart lesion, Bankart with 40 % Hill–Sachs lesion, Bankart repair, Bankart repair with remplissage, and remplissage repair alone. Humeral external rotation (ER) and total range of motion increased significantly after the creation of the Bankart lesion at both 0° and 60° abduction. The Bankart repair restored ER to intact values at 0° and 60° abduction, and the addition of the remplissage repair did not significantly alter range of motion from the Bankart repair alone. AP translation increased following the creation of the Bankart and Hill–Sachs lesions and was restored with the Bankart repair; the remplissage did not alter translation from the Bankart repair alone. At maximum ER at 60° abduction, the apex of the humeral head shifted posteriorly and inferiorly with remplissage repair. The addition of the remplissage procedure combined with Bankart repair for treatment of large Hill–Sachs lesions had no statistically significant effect on ROM or translation, but altered the kinematics of the glenohumeral joint. Thus, by addressing the humeral bone defect following an anterior shoulder dislocation, the remplissage technique with concurrent Bankart repair may be a relatively minimally invasive option for converting engaging Hill–Sachs lesions to non-engaging and promoting shoulder stability, though further biomechanical and clinical studies are warranted.
- 9 February 2014
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 24 (2) , 365-373
Biomechanical effects of anterior capsular plication and rotator interval closure in simulated anterior shoulder instability
The purpose of this study was to determine the effect of a stepwise arthroscopic anterior plication and arthroscopic-equivalent rotator interval (RI) closure on glenohumeral range of motion, kinematics, and translation in the setting of anterior instability. Six cadaveric shoulders were stretched to 10 % beyond maximum external rotation (ER) to create an anterior shoulder instability model. Range of motion, kinematics, and glenohumeral translations were recorded for the following conditions: (1) intact, (2) stretched, (3) after anterior capsular plication, and (4) after RI closure. The total range of motion after capsular stretching increased significantly in the 60° abduction position (p = 0.037). Average ER and total rotation were significantly decreased from the intact and stretched conditions by both repair conditions at 60° and 0° of glenohumeral abduction (p < 0.05), with no significant difference between plication and additional RI closure. At 0° abduction and 0° ER, glenohumeral translation decreased significantly from the stretched condition after RI closure with 10 and 15 N anterior and 10 N posterior loads (p < 0.05). At 30° ER, translation after RI closure was significantly less than both the intact and stretched conditions with 10 N anterior loads (p = 0.009; p = 0.004). These changes in translational stability were not seen with plication alone. Anterior capsular plication reduced glenohumeral range of motion back to the intact state, and often tighter. RI closure did not contribute significantly to the reduction in the range of motion, but had implications regarding glenohumeral translation. Caution should be taken when performing anterior plication and combined repairs to avoid overtightening. Intraoperative translations could be useful when debating RI closure in patients with unidirectional anterior glenohumeral instability.
- 9 February 2014
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 24 (2) , 365-373
Biomechanical effects of anterior capsular plication and rotator interval closure in simulated anterior shoulder instability
The purpose of this study was to determine the effect of a stepwise arthroscopic anterior plication and arthroscopic-equivalent rotator interval (RI) closure on glenohumeral range of motion, kinematics, and translation in the setting of anterior instability. Six cadaveric shoulders were stretched to 10 % beyond maximum external rotation (ER) to create an anterior shoulder instability model. Range of motion, kinematics, and glenohumeral translations were recorded for the following conditions: (1) intact, (2) stretched, (3) after anterior capsular plication, and (4) after RI closure. The total range of motion after capsular stretching increased significantly in the 60° abduction position (p = 0.037). Average ER and total rotation were significantly decreased from the intact and stretched conditions by both repair conditions at 60° and 0° of glenohumeral abduction (p < 0.05), with no significant difference between plication and additional RI closure. At 0° abduction and 0° ER, glenohumeral translation decreased significantly from the stretched condition after RI closure with 10 and 15 N anterior and 10 N posterior loads (p < 0.05). At 30° ER, translation after RI closure was significantly less than both the intact and stretched conditions with 10 N anterior loads (p = 0.009; p = 0.004). These changes in translational stability were not seen with plication alone. Anterior capsular plication reduced glenohumeral range of motion back to the intact state, and often tighter. RI closure did not contribute significantly to the reduction in the range of motion, but had implications regarding glenohumeral translation. Caution should be taken when performing anterior plication and combined repairs to avoid overtightening. Intraoperative translations could be useful when debating RI closure in patients with unidirectional anterior glenohumeral instability.