Giorgio Di Rocco
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Giorgio Di Rocco has a total of 91 co-authors. Here are the top co-authors by number of shared publications:
- Adriano Redler
“Sapienza” University of Rome
8 shared publications A Redler
5 shared publications- Alberto Santoro
Sapienza University of Rome, Rome, Italy
4 shared publications D Giannotti
4 shared publications- Gregorio Patrizi
Dipartimento di Scienze Chirurgiche, Policlinico Umberto I, Università di Roma“La Sapienza”, Rome, Italy
4 shared publications - Roberto Cirocchi
Department of Medicine and Surgery, University of Perugia, 06123 Perugia, Italy
4 shared publications
Latest Publications
- Open Access
- 3 May 2015
- Published by Springer Nature in BMC Surgery
- Vol. 15 (1) , 54
Spider surgical system versus multiport laparoscopic surgery: performance comparison on a surgical simulator
Background The rising interest towards minimally invasive surgery has led to the introduction of laparo-endoscopic single site (LESS) surgery as the natural evolution of conventional multiport laparoscopy. However, this new surgical approach is hampered with peculiar technical difficulties. The SPIDER surgical system has been developed in the attempt to overcome some of these challenges. Our study aimed to compare standard laparoscopy and SPIDER technical performance on a surgical simulator, using standardized tasks from the Fundamentals of Laparoscopic Surgery (FLS). Methods Twenty participants were divided into two groups based on their surgical laparoscopic experience: 10 PGY1 residents were included in the inexperienced group and 10 laparoscopists in the experienced group. Participants performed the FLS pegboard transfers task and pattern cutting task on a laparoscopic box trainer. Objective task scores and subjective questionnaire rating scales were used to compare conventional laparoscopy and SPIDER surgical system. Results Both groups performed significantly better in the FLS scores on the standard laparoscopic simulator compared to the SPIDER. Inexperienced group: Task 1 scores (median 252.5 vs. 228.5; p = 0.007); Task 2 scores (median 270.5 vs. 219.0; p = 0.005). Experienced group: Task 1 scores (median 411.5 vs. 309.5; p = 0.005); Task 2 scores (median 418.0 vs. 331.5; p = 0.007). Same aspects were highlighted for the subjective evaluations, except for the inexperienced surgeons who found both devices equivalent in terms of ease of use only in the peg transfer task. Conclusions Even though the SPIDER is an innovative and promising device, our study proved that it is more challenging than conventional laparoscopy in a population with different degrees of surgical experience. We presume that a possible way to overcome such challenges could be the development of tailored training programs through simulation methods. This may represent an effective way to deliver training, achieve mastery and skills and prepare surgeons for their future clinical experience.
- 3 May 2015
- Published by Springer Nature in BMC Surgery
- Vol. 15 (1) , 54
Open AccessSpider surgical system versus multiport laparoscopic surgery: performance comparison on a surgical simulator
Background The rising interest towards minimally invasive surgery has led to the introduction of laparo-endoscopic single site (LESS) surgery as the natural evolution of conventional multiport laparoscopy. However, this new surgical approach is hampered with peculiar technical difficulties. The SPIDER surgical system has been developed in the attempt to overcome some of these challenges. Our study aimed to compare standard laparoscopy and SPIDER technical performance on a surgical simulator, using standardized tasks from the Fundamentals of Laparoscopic Surgery (FLS). Methods Twenty participants were divided into two groups based on their surgical laparoscopic experience: 10 PGY1 residents were included in the inexperienced group and 10 laparoscopists in the experienced group. Participants performed the FLS pegboard transfers task and pattern cutting task on a laparoscopic box trainer. Objective task scores and subjective questionnaire rating scales were used to compare conventional laparoscopy and SPIDER surgical system. Results Both groups performed significantly better in the FLS scores on the standard laparoscopic simulator compared to the SPIDER. Inexperienced group: Task 1 scores (median 252.5 vs. 228.5; p = 0.007); Task 2 scores (median 270.5 vs. 219.0; p = 0.005). Experienced group: Task 1 scores (median 411.5 vs. 309.5; p = 0.005); Task 2 scores (median 418.0 vs. 331.5; p = 0.007). Same aspects were highlighted for the subjective evaluations, except for the inexperienced surgeons who found both devices equivalent in terms of ease of use only in the peg transfer task. Conclusions Even though the SPIDER is an innovative and promising device, our study proved that it is more challenging than conventional laparoscopy in a population with different degrees of surgical experience. We presume that a possible way to overcome such challenges could be the development of tailored training programs through simulation methods. This may represent an effective way to deliver training, achieve mastery and skills and prepare surgeons for their future clinical experience.
- 6 December 2014
- Published by Springer Nature in Surgical Endoscopy
- Vol. 29 (8) , 2339-2343
Intragastric balloon for obesity treatment: results of a multicentric evaluation for balloons left in place for more than 6 months
Obesity is a major risk factor for several chronic diseases. The BioEnterics® Intragastric Balloon (BIB®) is used worldwide as a short-term (6 months) treatment in morbid obese patients. However, removal of BIB® past 6 months is a common occurrence in clinical practice often as a result of patient factors. The aim of the present Italian multicentre cohort study was to evaluate the safety and efficacy of the BIB® left in situ for more than 6 months. A total of eight Italian centres participated in the study. Participating centres received a standardised questionnaire designed to capture safety and efficacy data. Weight loss data, as well as date, and reason for removal of the BIB® after 6 months were recorded. Adverse events, including mortality and complications, operators’ subjective technical notes and findings, and difficulties during removal procedure were also collected. Six hundred and eleven patients were included. In the majority of cases, patient extended BIB® treatment due to satisfactory weight loss (44 %). At 6 months, all patients achieved a BMI statistically lower than the initial BMI (p < 0.001). There was a non-significant trend towards greater BMIL % in patients who underwent removal up to 15 months versus the results achieved up to 6 months. No major complications were recorded. Extending the duration of BIB® use up to 14 months safely maintains weight loss and satiety with greater results than that up to 6 months, without complications.
- 6 December 2014
- Published by Springer Nature in Surgical Endoscopy
- Vol. 29 (8) , 2339-2343
Intragastric balloon for obesity treatment: results of a multicentric evaluation for balloons left in place for more than 6 months
Obesity is a major risk factor for several chronic diseases. The BioEnterics® Intragastric Balloon (BIB®) is used worldwide as a short-term (6 months) treatment in morbid obese patients. However, removal of BIB® past 6 months is a common occurrence in clinical practice often as a result of patient factors. The aim of the present Italian multicentre cohort study was to evaluate the safety and efficacy of the BIB® left in situ for more than 6 months. A total of eight Italian centres participated in the study. Participating centres received a standardised questionnaire designed to capture safety and efficacy data. Weight loss data, as well as date, and reason for removal of the BIB® after 6 months were recorded. Adverse events, including mortality and complications, operators’ subjective technical notes and findings, and difficulties during removal procedure were also collected. Six hundred and eleven patients were included. In the majority of cases, patient extended BIB® treatment due to satisfactory weight loss (44 %). At 6 months, all patients achieved a BMI statistically lower than the initial BMI (p < 0.001). There was a non-significant trend towards greater BMIL % in patients who underwent removal up to 15 months versus the results achieved up to 6 months. No major complications were recorded. Extending the duration of BIB® use up to 14 months safely maintains weight loss and satiety with greater results than that up to 6 months, without complications.
- Open Access
- 23 September 2014
- Published by Springer Nature in World Journal of Surgical Oncology
- Vol. 12 (1) , 1-7
Robotic distal pancreatectomy with or without preservation of spleen: a technical note
Distal pancreatectomy (DP) is a surgical procedure performed to remove the pancreatic tail jointly with a variable part of the pancreatic body and including a spleen resection in the case of conventional distal pancreatectomy or not in the spleen-preserving distal pancreatectomy. In this article, we describe a standardized operative technique for fully robotic distal pancreatectomy. In the last decade, the use of robotic systems has become increasingly common as an approach for benign and malignant pancreatic disease treatment. Robotic Distal Pancreatectomy (RDP) is an emerging technology for which sufficient data to draw definitive conclusions in surgical oncology are still not available because the follow-up period after surgery is too short (less than 2 years). RDP is an emerging technology for which sufficient data to draw definitive conclusions of value in surgical oncology are still not available, however this techniques is safe and reproducible by surgeons that possess adequate skills.
- 23 September 2014
- Published by Springer Nature in World Journal of Surgical Oncology
- Vol. 12 (1) , 1-7
Open AccessRobotic distal pancreatectomy with or without preservation of spleen: a technical note
Distal pancreatectomy (DP) is a surgical procedure performed to remove the pancreatic tail jointly with a variable part of the pancreatic body and including a spleen resection in the case of conventional distal pancreatectomy or not in the spleen-preserving distal pancreatectomy. In this article, we describe a standardized operative technique for fully robotic distal pancreatectomy. In the last decade, the use of robotic systems has become increasingly common as an approach for benign and malignant pancreatic disease treatment. Robotic Distal Pancreatectomy (RDP) is an emerging technology for which sufficient data to draw definitive conclusions in surgical oncology are still not available because the follow-up period after surgery is too short (less than 2 years). RDP is an emerging technology for which sufficient data to draw definitive conclusions of value in surgical oncology are still not available, however this techniques is safe and reproducible by surgeons that possess adequate skills.
- 1 March 2014
- Published by Elsevier in European Journal of Radiology
- Vol. 83 (3) , 420-428
Ultrasound elastography in the evaluation of thyroid pathology. Current status
- 1 March 2014
- Published by Elsevier in European Journal of Radiology
- Vol. 83 (3) , 420-428
Ultrasound elastography in the evaluation of thyroid pathology. Current status
- Open Access
- 16 September 2013
- Published by Springer Nature in BMC Surgery
- Vol. 13 (S1) , A47
Advantages of carotid revascularization in the elderly
- 16 September 2013
- Published by Springer Nature in BMC Surgery
- Vol. 13 (S1) , A47
Open AccessAdvantages of carotid revascularization in the elderly
- 1 August 2013
- Vol. 17 (16) , 2267-9
Double ileo-ceco-colic invagination due to right colon carcinoma: clinical presentation and management.
Intestinal intussusceptions represent a rare cause of intestinal obstruction in adults (about 1% of intestinal obstructions). The principle causes are benign or malignant tumors. In adults, the most frequent localizations of intestinal invaginations are the ileo-cecal segment, ileum and colon as exclusive localization. We report the case of a 56 year-old Caucasian male admitted in our Department complaining with diffuse abdominal pain and severe anemia. The colonoscopy revealed a vegetant, stenosing and ulcerated mass in the hepatic flexure. The computed tomography suggested the additional diagnosis of intestinal intussusception with no evidence of intestinal obstruction. In our experience, surgery is always indicated for the treatment of intussusceptions in adults, especially for the almost constant underlying neoplasm.
- 1 August 2013
- Vol. 17 (16) , 2267-9
Double ileo-ceco-colic invagination due to right colon carcinoma: clinical presentation and management.
Intestinal intussusceptions represent a rare cause of intestinal obstruction in adults (about 1% of intestinal obstructions). The principle causes are benign or malignant tumors. In adults, the most frequent localizations of intestinal invaginations are the ileo-cecal segment, ileum and colon as exclusive localization. We report the case of a 56 year-old Caucasian male admitted in our Department complaining with diffuse abdominal pain and severe anemia. The colonoscopy revealed a vegetant, stenosing and ulcerated mass in the hepatic flexure. The computed tomography suggested the additional diagnosis of intestinal intussusception with no evidence of intestinal obstruction. In our experience, surgery is always indicated for the treatment of intussusceptions in adults, especially for the almost constant underlying neoplasm.
- 1 March 2013
- Vol. 17 (6) , 842-4
Transmesenteric hernia after right nephrectomy: diagnostic and therapeutic management.
Internal abdominal hernias are a rare cause of intestinal obstruction (0.2-0.9%). Transmesenteric hernia is a rare type of internal hernia and usually in adult people is acquired. We report the case of a 44 year-old caucasian female with a small bowel occlusion after right nephrectomy for clear cell renal carcinoma caused by an acquired transmesenteric hernia. We emphasize the role of CT scanning for a prompt diagnosis and a quick surgical treatment in order to avoid intestinal gangrene.
- 1 March 2013
- Vol. 17 (6) , 842-4
Transmesenteric hernia after right nephrectomy: diagnostic and therapeutic management.
Internal abdominal hernias are a rare cause of intestinal obstruction (0.2-0.9%). Transmesenteric hernia is a rare type of internal hernia and usually in adult people is acquired. We report the case of a 44 year-old caucasian female with a small bowel occlusion after right nephrectomy for clear cell renal carcinoma caused by an acquired transmesenteric hernia. We emphasize the role of CT scanning for a prompt diagnosis and a quick surgical treatment in order to avoid intestinal gangrene.
- 1 December 2012
- Vol. 16 (15) , 2171-4
Two-years follow-up of low-dose methotrexate and 6-methylprednisolone therapy in a patient with idiopathic retroperitoneal fibrosis.
Retroperitoneal fibrosis (RPF), also known as Ormond's disease, is a rare fibroinflammatory disease with uncertain etiology. RPF is characterized by the presence of a particular retroperitoneal fibrotic tissue which is white, woody and involving retroperitoneal structures such as the great vessels, ureters and psoas muscle. The main complication of RPF is the obstruction of local structures such as the ureters due to the fibrosis and the treatment of this aspect represents the main challenge for this pathology. RPF medical treatment consists of corticosteroids or/and immunosuppressive therapy. We report a case of a patient affected by idiopathic RPF treated with low-dose methotrexate (MTX) and 6-methylprednisolone (6-MP) for two years, describing and confirming the effectiveness and safety of a long-term low-dose MTX and 6-MP treatment associated to ureteral Double-J stenting avoiding more invasive surgical approaches.
- 1 December 2012
- Vol. 16 (15) , 2171-4
Two-years follow-up of low-dose methotrexate and 6-methylprednisolone therapy in a patient with idiopathic retroperitoneal fibrosis.
Retroperitoneal fibrosis (RPF), also known as Ormond's disease, is a rare fibroinflammatory disease with uncertain etiology. RPF is characterized by the presence of a particular retroperitoneal fibrotic tissue which is white, woody and involving retroperitoneal structures such as the great vessels, ureters and psoas muscle. The main complication of RPF is the obstruction of local structures such as the ureters due to the fibrosis and the treatment of this aspect represents the main challenge for this pathology. RPF medical treatment consists of corticosteroids or/and immunosuppressive therapy. We report a case of a patient affected by idiopathic RPF treated with low-dose methotrexate (MTX) and 6-methylprednisolone (6-MP) for two years, describing and confirming the effectiveness and safety of a long-term low-dose MTX and 6-MP treatment associated to ureteral Double-J stenting avoiding more invasive surgical approaches.
- 1 June 2012
- Vol. 16 (6) , 845-7
Mediastinal parathyroid adenoma: a case report.
Ectopic parathyroid adenomas represent a diagnostic challenge, since they are quite rare in clinical practice. We present a case of a 61 years old man with symptomatic hypercalcemia due to an ectopic parathyroid adenoma in the upper-anterior mediastinum that was not localized by the scintigraphy. Ultrasonography identified a nodule on the left upper-superior lobe of the thyroid gland, consistent with a parathyroid adenoma; scintigraphy showed two focuses of abnormal tracer uptake, one on the left upper-superior lobe of the gland and the other on the right inferior lobe of the gland. Patient underwent surgery to remove the adenoma on the left side, but postoperatively PTH and serum calcium level were still elevated. CT scan showed a mass of 27 x 22 mm in the upper anterior mediastinum, in front of the right emisoma of D2. The final surgery allowed us to remove the adenoma with a laterocervical approach. The histopathology was consistent with parathyroid adenoma.
- 1 June 2012
- Vol. 16 (6) , 845-7
Mediastinal parathyroid adenoma: a case report.
Ectopic parathyroid adenomas represent a diagnostic challenge, since they are quite rare in clinical practice. We present a case of a 61 years old man with symptomatic hypercalcemia due to an ectopic parathyroid adenoma in the upper-anterior mediastinum that was not localized by the scintigraphy. Ultrasonography identified a nodule on the left upper-superior lobe of the thyroid gland, consistent with a parathyroid adenoma; scintigraphy showed two focuses of abnormal tracer uptake, one on the left upper-superior lobe of the gland and the other on the right inferior lobe of the gland. Patient underwent surgery to remove the adenoma on the left side, but postoperatively PTH and serum calcium level were still elevated. CT scan showed a mass of 27 x 22 mm in the upper anterior mediastinum, in front of the right emisoma of D2. The final surgery allowed us to remove the adenoma with a laterocervical approach. The histopathology was consistent with parathyroid adenoma.
- Open Access
- 9 November 2011
- Published by Springer Nature in World Journal of Surgical Oncology
- Vol. 9 (1) , 1-5
High tie versus low tie of the inferior mesenteric artery: a protocol for a systematic review
In anterior resection of rectum, the section level of inferior mesenteric artery is still subject of controversy between the advocates of high and low tie. The low tie is the division and ligation to the branching of the left colic artery and the high tie is the division and ligation at its origin at the aorta. We intend to assess current scientific evidence in literature and to establish the differences comparing technique, anatomy and physiology. The aim of this protocol is to achieve a meta-analysis that tests safety and feasibility of the two procedures with several types of outcome measures.
- 9 November 2011
- Published by Springer Nature in World Journal of Surgical Oncology
- Vol. 9 (1) , 1-5
Open AccessHigh tie versus low tie of the inferior mesenteric artery: a protocol for a systematic review
In anterior resection of rectum, the section level of inferior mesenteric artery is still subject of controversy between the advocates of high and low tie. The low tie is the division and ligation to the branching of the left colic artery and the high tie is the division and ligation at its origin at the aorta. We intend to assess current scientific evidence in literature and to establish the differences comparing technique, anatomy and physiology. The aim of this protocol is to achieve a meta-analysis that tests safety and feasibility of the two procedures with several types of outcome measures.