BLBor-Shyh Lin

Bor-Shyh Lin

*This is an algorithmically generated author record based on publicly available information.

Bor-Shyh Lin has a total of 34 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Design of Wearable Breathing Sound Monitoring System for Real-Time Wheeze Detection

    by Shih-Hong Li, Bor-Shing Lin, Chen-Han Tsai, Cheng-Ta Yang, Bor-Shyh Lin

    In the clinic, the wheezing sound is usually considered as an indicator symptom to reflect the degree of airway obstruction. The auscultation approach is the most common way to diagnose wheezing sounds, but it subjectively depends on the experience of the physician. Several previous studies attempted to extract the features of breathing sounds to detect wheezing sounds automatically. However, there is still a lack of suitable monitoring systems for real-time wheeze detection in daily life. In this study, a wearable and wireless breathing sound monitoring system for real-time wheeze detection was proposed. Moreover, a breathing sounds analysis algorithm was designed to continuously extract and analyze the features of breathing sounds to provide the objectively quantitative information of breathing sounds to professional physicians. Here, normalized spectral integration (NSI) was also designed and applied in wheeze detection. The proposed algorithm required only short-term data of breathing sounds and lower computational complexity to perform real-time wheeze detection, and is suitable to be implemented in a commercial portable device, which contains relatively low computing power and memory. From the experimental results, the proposed system could provide good performance on wheeze detection exactly and might be a useful assisting tool for analysis of breathing sounds in clinical diagnosis.


  • Novel non-contact control system of electric bed for medical healthcare

    by Chi-Chun Lo, Shang-Ho Tsai, Bor-Shyh Lin

    A novel non-contact controller of the electric bed for medical healthcare was proposed in this study. Nowadays, the electric beds are widely used for hospitals and home-care, and the conventional control method of the electric beds usually involves in the manual operation. However, it is more difficult for the disabled and bedridden patients, who might totally depend on others, to operate the conventional electric beds by themselves. Different from the current controlling method, the proposed system provides a new concept of controlling the electric bed via visual stimuli, without manual operation. The disabled patients could operate the electric bed by focusing on the control icons of a visual stimulus tablet in the proposed system. Besides, a wearable and wireless EEG acquisition module was also implemented to monitor the EEG signals of patients. The experimental results showed that the proposed system successfully measured and extracted the EEG features related to visual stimuli, and the disabled patients could operate the adjustable function of the electric bed by themselves to effectively reduce the long-term care burden.


  • Open Access

    A Wearable Channel Selection-Based Brain-Computer Interface for Motor Imagery Detection

    by Chi-Chun Lo, Tsung-Yi Chien, Yu-Chun Chen, Shang-Ho Tsai, Wai-Chi Fang, Bor-Shyh Lin

    Motor imagery-based brain-computer interface (BCI) is a communication interface between an external machine and the brain. Many kinds of spatial filters are used in BCIs to enhance the electroencephalography (EEG) features related to motor imagery. The approach of channel selection, developed to reserve meaningful EEG channels, is also an important technique for the development of BCIs. However, current BCI systems require a conventional EEG machine and EEG electrodes with conductive gel to acquire multi-channel EEG signals and then transmit these EEG signals to the back-end computer to perform the approach of channel selection. This reduces the convenience of use in daily life and increases the limitations of BCI applications. In order to improve the above issues, a novel wearable channel selection-based brain-computer interface is proposed. Here, retractable comb-shaped active dry electrodes are designed to measure the EEG signals on a hairy site, without conductive gel. By the design of analog CAR spatial filters and the firmware of EEG acquisition module, the function of spatial filters could be performed without any calculation, and channel selection could be performed in the front-end device to improve the practicability of detecting motor imagery in the wearable EEG device directly or in commercial mobile phones or tablets, which may have relatively low system specifications. Finally, the performance of the proposed BCI is investigated, and the experimental results show that the proposed system is a good wearable BCI system prototype.


  • Open Access

    Design of a Mobile Brain Computer Interface-Based Smart Multimedia Controller

    by Kevin C. Tseng, Bor-Shing Lin, Alice May-Kuen Wong, Bor-Shyh Lin

    Music is a way of expressing our feelings and emotions. Suitable music can positively affect people. However, current multimedia control methods, such as manual selection or automatic random mechanisms, which are now applied broadly in MP3 and CD players, cannot adaptively select suitable music according to the user’s physiological state. In this study, a brain computer interface-based smart multimedia controller was proposed to select music in different situations according to the user’s physiological state. Here, a commercial mobile tablet was used as the multimedia platform, and a wireless multi-channel electroencephalograph (EEG) acquisition module was designed for real-time EEG monitoring. A smart multimedia control program built in the multimedia platform was developed to analyze the user’s EEG feature and select music according his/her state. The relationship between the user’s state and music sorted by listener’s preference was also examined in this study. The experimental results show that real-time music biofeedback according a user’s EEG feature may positively improve the user’s attention state.


  • Open Access

    Novel Wearable and Wireless Ring-Type Pulse Oximeter with Multi-Detectors

    by Cheng-Yang Huang, Ming-Che Chan, Chien-Yue Chen, Bor-Shyh Lin

    The pulse oximeter is a popular instrument to monitor the arterial oxygen saturation (SPO2). Although a fingertip-type pulse oximeter is the mainstream one on the market at present, it is still inconvenient for long-term monitoring, in particular, with respect to motion. Therefore, the development of a wearable pulse oximeter, such as a finger base-type pulse oximeter, can effectively solve the above issue. However, the tissue structure of the finger base is complex, and there is lack of detailed information on the effect of the light source and detector placement on measuring SPO2. In this study, the practicability of a ring-type pulse oximeter with a multi-detector was investigated by optical human tissue simulation. The optimal design of a ring-type pulse oximeter that can provide the best efficiency of measuring SPO2 was discussed. The efficiency of ring-type pulse oximeters with a single detector and a multi-detector was also discussed. Finally, a wearable and wireless ring-type pulse oximeter was also implemented to validate the simulation results and was compared with the commercial fingertip-type pulse oximeter.


  • Open Access

    A PDMS-Based Cylindrical Hybrid Lens for Enhanced Fluorescence Detection in Microfluidic Systems

    by Bor-Shyh Lin, Yu-Ching Yang, Chong-Yi Ho, Han-Yu Yang, Hsiang-Yu Wang

    Microfluidic systems based on fluorescence detection have been developed and applied for many biological and chemical applications. Because of the tiny amount of sample in the system; the induced fluorescence can be weak. Therefore, most microfluidic systems deploy multiple optical components or sophisticated equipment to enhance the efficiency of fluorescence detection. However, these strategies encounter common issues of complex manufacturing processes and high costs. In this study; a miniature, cylindrical and hybrid lens made of polydimethylsiloxane (PDMS) to improve the fluorescence detection in microfluidic systems is proposed. The hybrid lens integrates a laser focusing lens and a fluorescence collecting lens to achieve dual functions and simplify optical setup. Moreover, PDMS has advantages of low-cost and straightforward fabrication compared with conventional optical components. The performance of the proposed lens is first examined with two fluorescent dyes and the results show that the lens provides satisfactory enhancement for fluorescence detection of Rhodamine 6G and Nile Red. The overall increments in collected fluorescence signal and detection sensitivity are more than 220% of those without lens, and the detection limits of Rhodamine 6G and Nile red are lowered to 0.01 μg/mL and 0.05 μg/mL, respectively. The hybrid lens is further applied to the detection of Nile red-labeled Chlorella vulgaris cells and it increases both signal intensity and detection sensitivity by more than 520%. The proposed hybrid lens also dramatically reduces the variation in detected signal caused by the deviation in incident angle of excitation light.


  • Panoramic stereo photography based on single-lens with a double-symmetric prism

    by Chien-Yue Chen, Qing-Long Deng, Wen-Shing Sun, Qiao-Yao Cheng, Bor-Shyh Lin, Ching-Lung Su

    Different from traditional panorama stereo acquisition technique shooting with numerous cameras, this study equips a double-symmetric prism in front of a single-lens camera to acquire images from four different angles of view, and the images acquired from the cameras every 20 degrees complete a pair of panorama stereo images with vertical angle of view ( ± 16 degrees) by image-based rendering. The panorama stereo acquisition technique reduces the number of cameras by three-fourth, and the acquired images contain vertical angles of view. Moreover, the image resolution is enhanced several times of the resolution of integral photography without moiré effect.


  • Transfer of a continuous-relief lenticular array onto a quartz substrate by using SIL combined with the dry-etching method

    by Qing-Long Deng, Chien-Yue Chen, Wei-Li Lin, Bor-Yuan Shew, Donyau Chiang, Yu-Hsiang Tang, Bor-Shyh Lin

  • Open Access

    Development of Novel Non-Contact Electrodes for Mobile Electrocardiogram Monitoring System

    by Bor-Shyh Lin, W. Chou, Hsing-Yu Wang, Yan-Jun Huang, Jeng-Shyang Pan

    Real-time monitoring of cardiac health is helpful for patients with cardiovascular disease. Many telemedicine systems based on ubiquitous computing and communication techniques have been proposed for monitoring the user's electrocardiogram (ECG) anywhere and anytime. Usually, wet electrodes are used in these telemedicine systems. However, wet electrodes require conduction gels and skin preparation that can be inconvenient and uncomfortable for users. In order to overcome this issue, a new non-contact electrode circuit was proposed and applied in developing a mobile electrocardiogram monitoring system. The proposed non-contact electrode can measure bio-potentials across thin clothing, allowing it to be embedded in a user's normal clothing to monitor ECG in daily life. We attempted to simplify the design of these non-contact electrodes to reduce power consumption while continuing to provide good signal quality. The electrical specifications and the performance of monitoring arrhythmia in clinical settings were also validated to investigate the reliability of the proposed design. Experimental results show that the proposed non-contact electrode provides good signal quality for measuring ECG across thin clothes.


  • Quartz-Blazed Grating Applied on Autostereoscopic Display

    by Chien-Yue Chen, Qing-Long Deng, Bor-Shyh Lin, Wen-Cheng Hung

    By applying reactive ion etching (RIE) to a blazed grating on quartz substrates, the grating can be utilized as a splitter in autostereoscopic displays. Furthermore, a solution for the pattern alignment on transparent substrates is also proposed. By measuring the diffraction efficiency and crosstalk between the left and right fields of view (FOV), the capability of the element to deliver stereoscopic images is demonstrated.