Michael Pfeiffer
Michael Pfeiffer has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
A. Wilke
Department of Orthopaedic Surgery
1 shared publicationAxel Wilke
Klinik für Orthopädie und Rheumatologie, Philipps-Universität, Baldingerstrasse, 35033 Marburg, Germany
1 shared publicationB. Deike
Department of Orthopaedic Surgery
1 shared publicationDunja Pfeiffer
Klinik für Orthopädie und Rheumatologie, Philipps-Universität, Baldingerstrasse, 35033 Marburg, Germany
1 shared publicationJ.D. Clausen
Department of Orthopaedic Surgery
1 shared publicationMichael Grande
Philipps-Universität
1 shared publication
Latest Publications
- Open Access
- 1 August 2003
- Published by Springer Nature in European Spine Journal
- Vol. 12 (4) , 369-377
Evaluation of indication-based use of transpedicular instrumentations with different rigidity for lumbar spinal fusion: a prospective pilot study with 3 years of follow-up
In a prospective cohort study in 94 patients with 3 years' follow-up the efficacy of rigid and semi-rigid transpedicular instrumentation for lumbar spine fusion was evaluated via three established scores. Patient groups were similar in respect of anthropometric data. The indication for using the semi-rigid technique was a fairly stable intraoperative situation; for the more common unstable situations, the rigid technique was chosen. Selecting implant rigidity on these criteria led to results with an improvement rate well within the upper success range reported in the literature. Among people in employment, a lengthy preoperative sick leave was an important predictor for unsatisfactory outcome.
- 1 August 2003
- Published by Springer Nature in European Spine Journal
- Vol. 12 (4) , 369-377
Open AccessEvaluation of indication-based use of transpedicular instrumentations with different rigidity for lumbar spinal fusion: a prospective pilot study with 3 years of follow-up
In a prospective cohort study in 94 patients with 3 years' follow-up the efficacy of rigid and semi-rigid transpedicular instrumentation for lumbar spine fusion was evaluated via three established scores. Patient groups were similar in respect of anthropometric data. The indication for using the semi-rigid technique was a fairly stable intraoperative situation; for the more common unstable situations, the rigid technique was chosen. Selecting implant rigidity on these criteria led to results with an improvement rate well within the upper success range reported in the literature. Among people in employment, a lengthy preoperative sick leave was an important predictor for unsatisfactory outcome.
- 1 February 2003
- Published by Springer Nature in European Spine Journal
- Vol. 12 (1) , 76-83
Intradiscal application of hyaluronic acid in the non-human primate lumbar spine: radiological results
Prospectively, with randomized segment-treatment assignment, and with blinded evaluators, lumbar motion segments in Cercopithecus monkeys were analyzed for macroscopic and radiological changes 24 weeks after nucleotomy and nucleotomy with additional intradiscal application of different hyaluronic acid formulations versus untreated control segments. The objective was to find out whether hyaluronic acid is able to influence the degenerative cascade in nonhuman primates after nucleotomy. In a similar procedure, hyaluronic acid has proven to decrease degeneration after nucleotomy in a Minipig model. This is the first such study ever undertaken in primates, thus trying to overcome the known limitations of non-primate spine models. Twenty monkeys with four segments each obtained nucleotomy in three segments and solely exposure of another control segment. Nucleotomy was performed from a transpsoatic retroperitoneal approach. Preoperative radiographs and follow-up radiographs, magnetic resonance imaging (MRI), computed tomography (CT), Q-CT with bone mineral density measurements and three-dimensional reconstruction were obtained and analyzed qualitatively and quantitatively. Segments with high-molecular-weight hyaluronic acid (Hylan G-F 20) application proved to be significantly superior over those with a standard nucleotomy in radiographs, MR images, CT scans, and macroscopic appearance at follow-up. Control segments remained unaffected. Interdependence between the different methods validated the utilized methods of quantitative radiological assessment of degeneration. Hylan G-F 20 appears to be a possible adjunct in reducing postoperative degeneration in an animal nucleotomy model. It deserves further evaluation, despite the fact that the mechanisms of its effects are still speculative.
- 1 February 2003
- Published by Springer Nature in European Spine Journal
- Vol. 12 (1) , 76-83
Intradiscal application of hyaluronic acid in the non-human primate lumbar spine: radiological results
Prospectively, with randomized segment-treatment assignment, and with blinded evaluators, lumbar motion segments in Cercopithecus monkeys were analyzed for macroscopic and radiological changes 24 weeks after nucleotomy and nucleotomy with additional intradiscal application of different hyaluronic acid formulations versus untreated control segments. The objective was to find out whether hyaluronic acid is able to influence the degenerative cascade in nonhuman primates after nucleotomy. In a similar procedure, hyaluronic acid has proven to decrease degeneration after nucleotomy in a Minipig model. This is the first such study ever undertaken in primates, thus trying to overcome the known limitations of non-primate spine models. Twenty monkeys with four segments each obtained nucleotomy in three segments and solely exposure of another control segment. Nucleotomy was performed from a transpsoatic retroperitoneal approach. Preoperative radiographs and follow-up radiographs, magnetic resonance imaging (MRI), computed tomography (CT), Q-CT with bone mineral density measurements and three-dimensional reconstruction were obtained and analyzed qualitatively and quantitatively. Segments with high-molecular-weight hyaluronic acid (Hylan G-F 20) application proved to be significantly superior over those with a standard nucleotomy in radiographs, MR images, CT scans, and macroscopic appearance at follow-up. Control segments remained unaffected. Interdependence between the different methods validated the utilized methods of quantitative radiological assessment of degeneration. Hylan G-F 20 appears to be a possible adjunct in reducing postoperative degeneration in an animal nucleotomy model. It deserves further evaluation, despite the fact that the mechanisms of its effects are still speculative.
- 1 October 2001
- Published by Springer Nature in European Spine Journal
- Vol. 10 (5) , 427-436
A new semirigid implant for instrumentation of scoliosis: preliminary report
- 1 October 2001
- Published by Springer Nature in European Spine Journal
- Vol. 10 (5) , 427-436
A new semirigid implant for instrumentation of scoliosis: preliminary report