Cheng Yang Tan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Cheng Yang Tan has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
A. Schempp
2 shared publicationsD. S. Bollinger
2 shared publicationsK. L. Duel
2 shared publicationsW. A. Pellico
2 shared publicationsB. A. Schupbach
1 shared publication- Benjamin Koubek
CERN, CH-1211 Geneva-23, Switzerland
1 shared publication
Latest Publications
- Open Access
Beam Tests of Beampipe Coatings for Electron Cloud Mitigation in Fermilab Main Injector
Electron cloud beam instabilities are an important consideration in virtually all high-energy particle accelerators and could pose a formidable challenge to forthcoming high-intensity accelerator upgrades. Dedicated tests have shown beampipe coatings dramatically reduce the density of electron cloud in particle accelerators. In this work, we evaluate the performance of titanium nitride, amorphous carbon, and diamond-like carbon as beampipe coatings for the mitigation of electron cloud in the Fermilab Main Injector. Altogether our tests represent 2700 ampere-hours of proton operation spanning five years. Three electron cloud detectors, retarding field analyzers, are installed in a straight section and allow a direct comparison between the electron flux in the coated and uncoated stainless steel beampipe. We characterize the electron flux as a function of intensity up to a maximum of 50 trillion protons per cycle. Each beampipe material conditions in response to electron bombardment from the electron cloud and we track the changes in these materials as a function of time and the number of absorbed electrons. Contamination from an unexpected vacuum leak revealed a potential vulnerability in the amorphous carbon beampipe coating. We measure the energy spectrum of electrons incident on the stainless steel, titanium nitride and amorphous carbon beampipes. We find the electron cloud signal is highly sensitive to stray magnetic fields and bunch-length over the Main Injector ramp cycle. We conduct a complete survey of the stray magnetic fields at the test station and compare the electron cloud signal to that in a field-free region.
Open AccessBeam Tests of Beampipe Coatings for Electron Cloud Mitigation in Fermilab Main Injector
Electron cloud beam instabilities are an important consideration in virtually all high-energy particle accelerators and could pose a formidable challenge to forthcoming high-intensity accelerator upgrades. Dedicated tests have shown beampipe coatings dramatically reduce the density of electron cloud in particle accelerators. In this work, we evaluate the performance of titanium nitride, amorphous carbon, and diamond-like carbon as beampipe coatings for the mitigation of electron cloud in the Fermilab Main Injector. Altogether our tests represent 2700 ampere-hours of proton operation spanning five years. Three electron cloud detectors, retarding field analyzers, are installed in a straight section and allow a direct comparison between the electron flux in the coated and uncoated stainless steel beampipe. We characterize the electron flux as a function of intensity up to a maximum of 50 trillion protons per cycle. Each beampipe material conditions in response to electron bombardment from the electron cloud and we track the changes in these materials as a function of time and the number of absorbed electrons. Contamination from an unexpected vacuum leak revealed a potential vulnerability in the amorphous carbon beampipe coating. We measure the energy spectrum of electrons incident on the stainless steel, titanium nitride and amorphous carbon beampipes. We find the electron cloud signal is highly sensitive to stray magnetic fields and bunch-length over the Main Injector ramp cycle. We conduct a complete survey of the stray magnetic fields at the test station and compare the electron cloud signal to that in a field-free region.
- Open Access
- 25 March 2014
- Published by American Physical Society (APS) in Physical Review Special Topics - Accelerators and Beams
- Vol. 17 (3)
Investigations of the output energy deviation and other parameters during commissioning of the four-rod radio frequency quadrupole at the Fermi National Accelerator Laboratory
- 25 March 2014
- Published by American Physical Society (APS) in Physical Review Special Topics - Accelerators and Beams
- Vol. 17 (3)
Open AccessInvestigations of the output energy deviation and other parameters during commissioning of the four-rod radio frequency quadrupole at the Fermi National Accelerator Laboratory
- Open Access
- 29 January 2014
- Published by American Physical Society (APS) in Physical Review Special Topics - Accelerators and Beams
- Vol. 17 (1)
Simple lumped circuit model applied to field flatness tuning of four-rod radio frequency quadrupoles
- 29 January 2014
- Published by American Physical Society (APS) in Physical Review Special Topics - Accelerators and Beams
- Vol. 17 (1)
Open AccessSimple lumped circuit model applied to field flatness tuning of four-rod radio frequency quadrupoles
- Open Access
The FNAL injector upgrade
The present FNAL H- injector has been operational since the 1970s and consists of two magnetron H- sources and two 750 keV Cockcroft-Walton Accelerators. In the upgrade, both slit-type magnetron sources will be replaced with circular aperture sources, and the Cockcroft-Waltons with a 200 MHz RFQ (radio frequency quadrupole). Operational experience at BNL (Brookhaven National Laboratory) has shown that the upgraded source and RFQ will be more reliable, improve beam quality and require less manpower than the present system.
Open AccessThe FNAL injector upgrade
The present FNAL H- injector has been operational since the 1970s and consists of two magnetron H- sources and two 750 keV Cockcroft-Walton Accelerators. In the upgrade, both slit-type magnetron sources will be replaced with circular aperture sources, and the Cockcroft-Waltons with a 200 MHz RFQ (radio frequency quadrupole). Operational experience at BNL (Brookhaven National Laboratory) has shown that the upgraded source and RFQ will be more reliable, improve beam quality and require less manpower than the present system.
- Open Access
- 4 March 2008
- Published by American Physical Society (APS) in Physical Review Special Topics - Accelerators and Beams
- Vol. 11 (3) , 032802
Analytic approximation of the head-tail phase difference from continuous transverse excitation for measuring chromaticity
We will explore a method for measuring chromaticity by continuously kicking the beam transversely. This is called the continuous head-tail method for measuring chromaticity. The complete analytic approximation in terms of trigonometric functions is derived for zero transverse emittance beam. A simple formula for calculating chromaticity from experimental data is also shown. Finally, the theory is compared with experimental data.
- 4 March 2008
- Published by American Physical Society (APS) in Physical Review Special Topics - Accelerators and Beams
- Vol. 11 (3) , 032802
Open AccessAnalytic approximation of the head-tail phase difference from continuous transverse excitation for measuring chromaticity
We will explore a method for measuring chromaticity by continuously kicking the beam transversely. This is called the continuous head-tail method for measuring chromaticity. The complete analytic approximation in terms of trigonometric functions is derived for zero transverse emittance beam. A simple formula for calculating chromaticity from experimental data is also shown. Finally, the theory is compared with experimental data.
- 15 February 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
Novel Tune Diagnostics for the Tevatron
In the Tevatron collider, protons and antiprotons share the same beam pipe. This poses a challenge in the measurement of tunes for both species simultanously because of the possibility of signal contamination from the other species. The tune of each bunch is also very different because of beam-beam effects from parasitic crossing points. This means that the tune diagnostics must be able to differentiate between protons and anti-protons, it also has to measure tunes from each bunch. There are three different tune pickups used in the Tevatron: 1.7 GHz Schottky pickups, 21.4 MHz Schottky pickups and baseband pickups. These devices will be discussed in detail in this paper.
- 15 February 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
Novel Tune Diagnostics for the Tevatron
In the Tevatron collider, protons and antiprotons share the same beam pipe. This poses a challenge in the measurement of tunes for both species simultanously because of the possibility of signal contamination from the other species. The tune of each bunch is also very different because of beam-beam effects from parasitic crossing points. This means that the tune diagnostics must be able to differentiate between protons and anti-protons, it also has to measure tunes from each bunch. There are three different tune pickups used in the Tevatron: 1.7 GHz Schottky pickups, 21.4 MHz Schottky pickups and baseband pickups. These devices will be discussed in detail in this paper.
- 1 February 2006
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 557 (2) , 615-620
Tune tracking with a PLL in the Tevatron
- 1 February 2006
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 557 (2) , 615-620
Tune tracking with a PLL in the Tevatron