AKAbdulkadir Kamal

Abdulkadir Kamal

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Abdulkadir Kamal has a total of 63 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Using a hand-held pupillometer to quantify pupil constriction as part of the accommodation reflex

    by DaiWai M. Olson, Anjali Perera, Abdulkadir Kamal, Maribel Jamili, Amber Salter, Haben Mehari, Moez M.I. Bashir

  • Quantitative Pupillometry Values Are Similar in Bright Light and Dim Light Conditions

    by Kylie MacLean Hall, Jennifer Wilson, Ty A. Johnson, Abdulkadir Kamal, DaiWai M. Olson

    Background: The recommendations to leave the lights on or turn the lights off before testing the pupillary light reflex (PLR) are primarily based on historical precedent. There is a lack of evidence to determine the best practice regarding adjusting ambient light when obtaining pupil measurements using a quantitative pupillometer (QP). Objectives: To examine the difference in QP measurements taken from the same subject in bright light versus in a darkened room. Method: Before the human subject study, light readings were obtained with a lux meter to identify the range and central tendency for light in an intensive care unit. A set of 4, paired-sample within-subjects QP measurements was obtained in alternating bright and dark rooms. Results: Among 32 healthy volunteers, we found neither statistical nor clinically relevant differences in the neurological pupil index score in paired observations ( P = .12) taken in bright light [mean = 561.5 (37.3) lux] or dark conditions [mean = 0.9 (0.3) lux]. This remained true in a mixed model controlling for repeated observations ( P = .25). Discussion: Pupil size was larger in dark conditions. But the finding that the pupillary light reflex functions normally despite fluctuating light levels is not unexpected. Conclusion: The evidence does not support a need for nurses to adjust light levels before measuring the PLR with a pupillometer.


  • The 2026 International Neuroscience Nursing Research Symposium Abstracts

    by Byron A. Carlisle, Sheila A. Alexander, Virginia Alvarado, Kim D. Barker, Moez M. I. Bashir, Paul D. Bosse, Alexis Cardenas, Andrea Chepkevich, Yvette Conley, Edward Cruz, et al.

  • Open Access

    Continuous recording to identify that there are at least 684 interventions for disorders of consciousness

    by Betsy Abraham, Brittany Doyle, Emerson B. Nairon, Lindsay M. Riskey, Abdulkadir Kamal, DaiWai M. Olson

    The care of patients with disorders of consciousness (DoC) is variable worldwide. The aim of this study was to create a comprehensive, mutually exclusive and collectively exhausted, list of medical and nursing care interventions provided to patients with DoCs including those not documented in the EMR to better understand the care given to coma patients. After obtaining consent from patients’ legally authorized representative, 12 hours of continuous video footage was collected inside the patient’s intensive care unit room. Five patients aged 25–69 with a Glascow Coma Scale (GCS) of six or less were enrolled for a total of 57 hours. There were 684 unique interventions (575 physical and 109 cognitive) observed during collective observation periods. The bedside nurse was involved in 500 (73.1%) unique interventions, and family members, providers, and other personnel provided the remaining 26.9% of interventions. There is need to standardize the treatment of patients with disorders of consciousness across patients and hospitals around the world.


  • Open Access

    There Is Significant Within-Subject Variation in the Time from Light Stimulus to Maximum Pupil Constriction Among Healthy Controls

    by Abdulkadir Kamal, Yohan Kim, Amber Salter, Shripal Gunna, Emerson B. Nairon, DaiWai M. Olson

    Background: Handheld quantitative pupilometers (QPs) measure each phase of the pupillary light reflex (PLR) and provide a summary score based on these values. One phase of the PLR is the period of time from the onset of light exposure to the maximum constriction of the pupil, also known as time to maximum constriction (tMC). Although tMC has been found to vary significantly among patients with neurological injury, there are no studies reporting tMC in healthy controls. This study addresses this gap. Methods: Subjects in this prospective observational study were healthy controls who provided paired (left and right eye) QP readings during four separate observations over the course of 2 days. The tMC was derived by determining the smallest observed pupil size during videos filmed at 30 frames per second, and we assessed within-subject variability using the coefficient of variance and intraclass correlation coefficient (ICC). Results: Fifty subjects provided 380 QP readings (190 left eye and 190 right eye). Subjects primarily identified as female (80%), non-Hispanic (86%), white (62%), and <40 years old (74%). The mean tMC was 1.0 (0.14) seconds (s) for the left eye and 1.0 (0.17) s for the right eye; the coefficient of variance ranged from 11.6% to 18.8% and the ICC ranged from 0.25 to 0.40. For the between-subject comparisons across the four observation periods, the left and right eye mean differences ranged from 0.001 to 0.063 and the ICC ranged from 0.12 to 0.52. Conclusions: The tMC values vary significantly in healthy controls. Changes in pupil function as a clinical biomarker of intracranial pathology are not fully understood. Identifying clinical correlations of tMC variation may provide insight for the prognostication and treatment of neurocritically ill patients.


  • Does intracranial pressure vary based on external ventricular drainage? A real-world clinical observation study

    by Dohee Kwon, Lindsay Riskey, Abdulkadir Kamal, Brittany R. Doyle, Brennen Louthen, Jade L. Marshall, Samir D. Ruxmohan, Amber Salter, DaiWai M. Olson


  • Measuring and Monitoring ICP in Neurocritical Care: Results from a National Practice Survey

    by DaiWai M. Olson, Hunt H. Batjer, Kamal Abdulkadir, Christiana E. Hall

    The use of intracranial pressure (ICP) monitors is nearly synonymous with Neurocritical Care. Recent studies in nursing literature have report high levels of practice variance associated with ICP monitoring and treatment. There are no recent practice surveys to describe how critical care physicians and nurses who are familiar with ICP management provide care to their patients. A short survey was developed and disseminated electronically to the members of the Neurocritical Care Society. The summary from 241 professionals provides evidence that there is significant practice variation associated with ICP monitoring and management. The results highlight the need to develop standardized approaches to measuring, monitoring, recording, and treating ICP.