Michael S. Kook
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Michael S. Kook has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Kyung-Rim Sung
Department of Ophthalmology, Asan Medical Center, University of Ulsan, College of Medicine, 388-1 Pungnapdong, Songpa-gu, 138-736 Seoul, Korea
2 shared publicationsWeechang Kang
Unit for Consulting Biostatistics, Asan Medical Center, University of Ulsan, College of Medicine, Seoul, Korea
2 shared publicationsHungwon Tchah
Department of Ophthalmology, Asan Medical Center, University of Ulsan, College of Medicine, 388-1 Pungnapdong, Songpa-gu, 138-736 Seoul, Korea
1 shared publicationK R Sung
1 shared publicationKyung-Rhee Kim
Department of Ophthalmology, Asan Medical Center, University of Ulsan, College of Medicine, 388-1 Pungnapdong, Songpa-gu, 138-736 Seoul, Korea
1 shared publicationRyuhwa Park
Department of Ophthalmology, University of Ulsan, College of Medicine, Songpa-gu, Seoul, 138–736, Korea, bUnit for Consulting Biostatistics, Asan Medical Center, 388–1 Pungnap-dong, Korea
1 shared publication
Latest Publications
- 28 May 2002
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 240 (6) , 448-456
Pattern of retinal nerve fiber layer damage in Korean eyes with normal-tension glaucoma and hemifield visual field defect
Purpose. To evaluate quantitatively the pattern of retinal nerve fiber layer (RNFL) damage in eyes with normal-tension glaucoma (NTG) with hemifield dominant visual field defects using scanning laser polarimetry. Methods. Prospectively, 40 consecutive eyes from 40 patients with NTG and hemifield defect based on the findings of examination using the Humphrey Field Analyzer underwent RNFL thickness measurements. Twenty normal eyes from 20 subjects matched in age and refractive error formed a control group. Results. Symmetry, calculated as the ratio of superior to inferior RNFL thickness, showed no statistically significant difference between the study group and the control group (P=0.50). Overall, 27.5% (11/40 eyes) showed an "abnormal" symmetry index that indicated focal RNFL change. The affected ratio, calculated as the ratio of RNFL thickness in the quadrant corresponding to the hemifield of visual field defect to that of the temporal quadrant was significantly lower in the study group than in the control group (PConclusion. Despite strict selection of the eyes with visual field defect confined to one hemifield, a mixture of both focal and diffuse RNFL damage was noted, with a common occurrence of symmetrical RNFL thinning in both upper and lower quadrants based on scanning laser polarimetry.
- 28 May 2002
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 240 (6) , 448-456
Pattern of retinal nerve fiber layer damage in Korean eyes with normal-tension glaucoma and hemifield visual field defect
Purpose. To evaluate quantitatively the pattern of retinal nerve fiber layer (RNFL) damage in eyes with normal-tension glaucoma (NTG) with hemifield dominant visual field defects using scanning laser polarimetry. Methods. Prospectively, 40 consecutive eyes from 40 patients with NTG and hemifield defect based on the findings of examination using the Humphrey Field Analyzer underwent RNFL thickness measurements. Twenty normal eyes from 20 subjects matched in age and refractive error formed a control group. Results. Symmetry, calculated as the ratio of superior to inferior RNFL thickness, showed no statistically significant difference between the study group and the control group (P=0.50). Overall, 27.5% (11/40 eyes) showed an "abnormal" symmetry index that indicated focal RNFL change. The affected ratio, calculated as the ratio of RNFL thickness in the quadrant corresponding to the hemifield of visual field defect to that of the temporal quadrant was significantly lower in the study group than in the control group (PConclusion. Despite strict selection of the eyes with visual field defect confined to one hemifield, a mixture of both focal and diffuse RNFL damage was noted, with a common occurrence of symmetrical RNFL thinning in both upper and lower quadrants based on scanning laser polarimetry.
- Open Access
- 1 October 2001
- Published by BMJ in British Journal of Ophthalmology
- Vol. 85 (10) , 1167-1170
Study of retinal nerve fibre layer thickness in eyes with high tension glaucoma and hemifield defect
AIM To quantitatively evaluate retinal nerve fibre layer (RNFL) difference in areas of apparently normal appearing visual field in eyes with high tension glaucoma (HTG) and hemifield defects using scanning laser polarimetry. METHODS 40 eyes from 40 patients with HTG with superior or inferior hemifield defects based on the Humphrey field analyser (HFA) underwent RNFL thickness measurements. 20 normal eyes from 20 subjects matched in age and refractive error were selected as a control group. The RNFL thickness was measured with a scanning laser polarimeter. Mean RNFL thickness was evaluated in four quadrants (superior, inferior, nasal, and temporal). A superior or inferior quadrant in the defined ring of scanning laser polarimetry corresponds to inferior or superior hemifield in HFA. RESULTS The mean RNFL thickness in the unaffected quadrant (the quadrant corresponding to the hemifield with apparently normal visual field based on HFA) of the HTG group was significantly thinner than the average RNFL thickness of the corresponding quadrant of the control eyes. The RNFL thickness of the unaffected quadrant in the eyes with HTG was reduced and statistically similar to that of the affected quadrant. Symmetry, calculated as the ratio of superior to inferior RNFL thickness, showed no statistical difference between the study and control group. CONCLUSION Changes in RNFL are present in the apparently normal hemifield in the eyes with HTG. The thickness of the RNFL is reduced symmetrically in both superior and inferior quadrants based on the GDx parameters.
- 1 October 2001
- Published by BMJ in British Journal of Ophthalmology
- Vol. 85 (10) , 1167-1170
Open AccessStudy of retinal nerve fibre layer thickness in eyes with high tension glaucoma and hemifield defect
AIM To quantitatively evaluate retinal nerve fibre layer (RNFL) difference in areas of apparently normal appearing visual field in eyes with high tension glaucoma (HTG) and hemifield defects using scanning laser polarimetry. METHODS 40 eyes from 40 patients with HTG with superior or inferior hemifield defects based on the Humphrey field analyser (HFA) underwent RNFL thickness measurements. 20 normal eyes from 20 subjects matched in age and refractive error were selected as a control group. The RNFL thickness was measured with a scanning laser polarimeter. Mean RNFL thickness was evaluated in four quadrants (superior, inferior, nasal, and temporal). A superior or inferior quadrant in the defined ring of scanning laser polarimetry corresponds to inferior or superior hemifield in HFA. RESULTS The mean RNFL thickness in the unaffected quadrant (the quadrant corresponding to the hemifield with apparently normal visual field based on HFA) of the HTG group was significantly thinner than the average RNFL thickness of the corresponding quadrant of the control eyes. The RNFL thickness of the unaffected quadrant in the eyes with HTG was reduced and statistically similar to that of the affected quadrant. Symmetry, calculated as the ratio of superior to inferior RNFL thickness, showed no statistical difference between the study and control group. CONCLUSION Changes in RNFL are present in the apparently normal hemifield in the eyes with HTG. The thickness of the RNFL is reduced symmetrically in both superior and inferior quadrants based on the GDx parameters.
- 1 February 2001
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 239 (2) , 118-121
Reproducibility of scanning laser polarimetry (GDx) of peripapillary retinal nerve fiber layer thickness in normal subjects
Purpose: To assess the reproducibility of measurement of retinal nerve fiber layer (RNFL) thickness among subjects using the GDx Nerve Fiber Analyzer (NFA). Methods: One eye of each of five young and healthy volunteers was imaged by three newly trained technicians (R.-H.P, K.-R.K., and S.-T.K.). Each volunteer was scanned six consecutive times for five independent times within a 1-month period. One composite image was selected out of three best images per session. Intra- and interoperator reproducibilities were calculated and the influence of placement of measurement ellipse by a single operator on interobserver reproducibility was also investigated. Results: Mean coefficients of variation for total integral value of RNFL were 3.67±1.47%, 3.86±2.13%, and 4.16±1.97%, respectively for the three technicians. Interoperator variability was not statistically significant (P=0.075), and the difference was even less if a single ellipse drawn by one operator was used in all measurements (P=0.1528) by repeated-measures analysis of variance (ANOVA). Conclusions: The results suggest that GDx NFA may provide acceptable intraoperator as well as interoperator reproducibility among Asian eyes.
- 1 February 2001
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 239 (2) , 118-121
Reproducibility of scanning laser polarimetry (GDx) of peripapillary retinal nerve fiber layer thickness in normal subjects
Purpose: To assess the reproducibility of measurement of retinal nerve fiber layer (RNFL) thickness among subjects using the GDx Nerve Fiber Analyzer (NFA). Methods: One eye of each of five young and healthy volunteers was imaged by three newly trained technicians (R.-H.P, K.-R.K., and S.-T.K.). Each volunteer was scanned six consecutive times for five independent times within a 1-month period. One composite image was selected out of three best images per session. Intra- and interoperator reproducibilities were calculated and the influence of placement of measurement ellipse by a single operator on interobserver reproducibility was also investigated. Results: Mean coefficients of variation for total integral value of RNFL were 3.67±1.47%, 3.86±2.13%, and 4.16±1.97%, respectively for the three technicians. Interoperator variability was not statistically significant (P=0.075), and the difference was even less if a single ellipse drawn by one operator was used in all measurements (P=0.1528) by repeated-measures analysis of variance (ANOVA). Conclusions: The results suggest that GDx NFA may provide acceptable intraoperator as well as interoperator reproducibility among Asian eyes.
- 1 January 1999
- Vol. 14 (1) , 33-8
The immediate effect of bilateral superior obliuqe tenotomy on primary position horizontal binocular alignment.
To evaluate the effect on primary position horizontal binocular alignment of superior oblique tenotomy for A-pattern exotropia with bilateral superior oblique overaction using new surgical and anesthesia techniques. We performed intraoperatively adjustable horizontal strabismus surgery under topical anesthesia in 6 cases of A-pattern exotropia. After adjusting the horizontal deviation nearly to orthotropia in primary position, we measured the angle of horizontal deviation in up-, primary, and downgaze positions. This was followed by bilateral superior oblique tenotomy and remeasurement of the horizontal deviation in the same 3 positions. Postoperatively we remeasured the deviation at one day, one month and three months. There was no immediate change in the horizontal deviation in primary position in 2 of the 6 patients, and 3-8 delta of immediate esotropic shift in 4 of the 6 patients (average 3.3 delta) after bilateral superior oblique tenotomy. At 3 months postop' the small esotropia noted at the immediate postop' measurement became orthotropic. There was a tendency of increased exotropic shift or becoming exotropic in those patients with slight exotropia or orthotropia at the immediate postop' measurement. But these shifts were minimal. When combined surgery of superior oblique and horizontal muscle is planned for A-pattern exotropia, the effect of bilateral superior oblique tenotomy on the primary position horizontal binocular alignment can be disregarded.
- 1 January 1999
- Vol. 14 (1) , 33-8
The immediate effect of bilateral superior obliuqe tenotomy on primary position horizontal binocular alignment.
To evaluate the effect on primary position horizontal binocular alignment of superior oblique tenotomy for A-pattern exotropia with bilateral superior oblique overaction using new surgical and anesthesia techniques. We performed intraoperatively adjustable horizontal strabismus surgery under topical anesthesia in 6 cases of A-pattern exotropia. After adjusting the horizontal deviation nearly to orthotropia in primary position, we measured the angle of horizontal deviation in up-, primary, and downgaze positions. This was followed by bilateral superior oblique tenotomy and remeasurement of the horizontal deviation in the same 3 positions. Postoperatively we remeasured the deviation at one day, one month and three months. There was no immediate change in the horizontal deviation in primary position in 2 of the 6 patients, and 3-8 delta of immediate esotropic shift in 4 of the 6 patients (average 3.3 delta) after bilateral superior oblique tenotomy. At 3 months postop' the small esotropia noted at the immediate postop' measurement became orthotropic. There was a tendency of increased exotropic shift or becoming exotropic in those patients with slight exotropia or orthotropia at the immediate postop' measurement. But these shifts were minimal. When combined surgery of superior oblique and horizontal muscle is planned for A-pattern exotropia, the effect of bilateral superior oblique tenotomy on the primary position horizontal binocular alignment can be disregarded.