M. Kisaki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
M. Kisaki has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
H. Nakano
National Institute for Fusion Science, National Institutes of Natural Sciences, 322-6 Oroshi Toki, Gifu 509-5292, Japan
8 shared publications- Masaki Osakabe
National Institute for Fusion Science
7 shared publications K. Ikeda
National Institute for Fusion Science, National Institutes of Natural Sciences, 322-6 Oroshi Toki, Gifu 509-5292, Japan
6 shared publicationsY. Takeiri
National Institute for Fusion Science(NIFS), National Institutes of Natural Sciences, 322-6 Oroshi, Toki, 509-5292 Japan
5 shared publicationsK. Nagaoka
National Institute for Fusion Science, National Institutes of Natural Sciences, 322-6 Oroshi, Toki, 509-5292 Japan
4 shared publicationsK. Tsumori
National Institute for Fusion Science, National Institutes of Natural Sciences, 322-6 Oroshi, Toki, 509-5292 Japan
4 shared publications
Latest Publications
- 28 December 2018
- Published by AIP Publishing
- Vol. 2052 (1) , 040015
Caesiated H- source operation with helium
The consumption rate of cesium (Cs) for negative hydrogen (H-) ion source increases when the source operation gas is changed from hydrogen to deuterium. There was observed a clear indication that a deuterium discharge erodes Cs atoms on the plasma grid (PG) surface to increase work function and the co-extracted electron current. We have proposed a model, that the enhanced sputtering yield of Cs from the PG due to deuterium ions, which carries more kinetic energy to Cs adsorbed on the surface directly or indirectly, is the main reason for this fast dissipation of Cs. Introduction of helium (He) into discharge can verify the enhanced sputtering effect due to the lager mass ions in the source discharge. Comparing the effect due to seeded Cs before and after the He injection into discharge through Cs OES signals as well as the H- density measured with cavity ring-down method, the sputtering/evaporation enhancement due to He is estimated. Neutral atoms and positive ions in the He discharge should cause enhanced sputtering like deuterium, while the system does not generate neutron under the induction of acceleration voltage to diagnose the extracted negative ion beam. Plasma parameters of the H2 and He plasmas are investigated by diagnostics tools installed on NIFS-RNIS (National Institute for Fusion Science, Research and development Negative Ion Source) together with H- density measurement by cavity ring down. Enhanced consumption rate of Cs is compared with proposed sputtering yield data to predict the rate for deuterium operation of negative ion sources.
- 28 December 2018
- Published by AIP Publishing
- Vol. 2052 (1) , 040015
Caesiated H- source operation with helium
The consumption rate of cesium (Cs) for negative hydrogen (H-) ion source increases when the source operation gas is changed from hydrogen to deuterium. There was observed a clear indication that a deuterium discharge erodes Cs atoms on the plasma grid (PG) surface to increase work function and the co-extracted electron current. We have proposed a model, that the enhanced sputtering yield of Cs from the PG due to deuterium ions, which carries more kinetic energy to Cs adsorbed on the surface directly or indirectly, is the main reason for this fast dissipation of Cs. Introduction of helium (He) into discharge can verify the enhanced sputtering effect due to the lager mass ions in the source discharge. Comparing the effect due to seeded Cs before and after the He injection into discharge through Cs OES signals as well as the H- density measured with cavity ring-down method, the sputtering/evaporation enhancement due to He is estimated. Neutral atoms and positive ions in the He discharge should cause enhanced sputtering like deuterium, while the system does not generate neutron under the induction of acceleration voltage to diagnose the extracted negative ion beam. Plasma parameters of the H2 and He plasmas are investigated by diagnostics tools installed on NIFS-RNIS (National Institute for Fusion Science, Research and development Negative Ion Source) together with H- density measurement by cavity ring down. Enhanced consumption rate of Cs is compared with proposed sputtering yield data to predict the rate for deuterium operation of negative ion sources.
- 21 September 2018
- Published by AIP Publishing
- Vol. 2011 (1) , 080003
First measurements of beam plasma in NIFS test stand
We report on the characteristics of the beam-generated plasma in the multibeamlet case of a hydrogen negative ion beam at NIFS. The plasma potential, and the energy of secondary particles in the drift region of an ion beam, offer an insight into the mechanisms that allow beam transport in low pressure gasses. The first measurements reported here were made by means of a four-gridded retarding field energy analyzer, combined with the measurement of the drain current at the beam dump, and with infrared beamlet monitoring technique. The retarding field analyzer measures the energy distributions of particles emitted radially from the beam-generated plasma [1]. The beam is dumped onto a graphite calorimeter, which is electrically insulated, so that it can be electrically biased and the collected current can be measured. The thermal image of the calorimeter is acquired during the beam pulse, thus offering a quantitative estimation of the single beamlet optics and multibeamlet focusing. Finally, the influence of the neutral gas density is studied by puffing hydrogen gas in this drift region. The measured ion and electron energy distribution functions are strongly affected by the electric bias of the calorimeter. For a 47kV, 0.3A beam, an electron temperature of 3eV at the plasma edge was found. The energy distribution of the ions for a pressure of about 0.03Pa is presented, from which the plasma potential can be inferred.
- 21 September 2018
- Published by AIP Publishing
- Vol. 2011 (1) , 080003
First measurements of beam plasma in NIFS test stand
We report on the characteristics of the beam-generated plasma in the multibeamlet case of a hydrogen negative ion beam at NIFS. The plasma potential, and the energy of secondary particles in the drift region of an ion beam, offer an insight into the mechanisms that allow beam transport in low pressure gasses. The first measurements reported here were made by means of a four-gridded retarding field energy analyzer, combined with the measurement of the drain current at the beam dump, and with infrared beamlet monitoring technique. The retarding field analyzer measures the energy distributions of particles emitted radially from the beam-generated plasma [1]. The beam is dumped onto a graphite calorimeter, which is electrically insulated, so that it can be electrically biased and the collected current can be measured. The thermal image of the calorimeter is acquired during the beam pulse, thus offering a quantitative estimation of the single beamlet optics and multibeamlet focusing. Finally, the influence of the neutral gas density is studied by puffing hydrogen gas in this drift region. The measured ion and electron energy distribution functions are strongly affected by the electric bias of the calorimeter. For a 47kV, 0.3A beam, an electron temperature of 3eV at the plasma edge was found. The energy distribution of the ions for a pressure of about 0.03Pa is presented, from which the plasma potential can be inferred.
- 21 September 2018
- Published by AIP Publishing
- Vol. 2011 (1) , 060002
First results of deuterium beam operation on neutral beam injectors in the large helical device
Deuterium beam operations on neutral beam injectors (NBI) have been carried out successfully in the Large Helical Device (LHD) in 2017. We injected a total of 31 MW neutral beam power, which gave us a new operation region for high ion temperature plasma. Upgrading the beam energy from 40 keV to 60 keV and then to 80 keV for deuterium operation in a positive ion based NBI (P-NBI) of BL4 and BL5, respectively, we have achieved 10.6 MW (75 keV) beam injection in the P-NBI. We confirmed a good arc efficiency (extracted beam current/arc power) with 83% high deuteron ratio which is the same as the hydrogen operation in the positive source. We also extracted deuterium ion beam from three negative-ion based NBIs (N-NBI) without increase beam energy, although the injection power decreased by less than half. The averaged arc efficiency of the deuterium negative ion is approximately 66% of the hydrogen case, and the current density of the accelerated beam current reached 190 A/m2. We have clearly found the lower limit of electron current ratio depending on the arc discharge power. Certainly, the extracted electron current ratio increased in deuterium operation. However, we have had no trouble on the beam line components.
- 21 September 2018
- Published by AIP Publishing
- Vol. 2011 (1) , 060002
First results of deuterium beam operation on neutral beam injectors in the large helical device
Deuterium beam operations on neutral beam injectors (NBI) have been carried out successfully in the Large Helical Device (LHD) in 2017. We injected a total of 31 MW neutral beam power, which gave us a new operation region for high ion temperature plasma. Upgrading the beam energy from 40 keV to 60 keV and then to 80 keV for deuterium operation in a positive ion based NBI (P-NBI) of BL4 and BL5, respectively, we have achieved 10.6 MW (75 keV) beam injection in the P-NBI. We confirmed a good arc efficiency (extracted beam current/arc power) with 83% high deuteron ratio which is the same as the hydrogen operation in the positive source. We also extracted deuterium ion beam from three negative-ion based NBIs (N-NBI) without increase beam energy, although the injection power decreased by less than half. The averaged arc efficiency of the deuterium negative ion is approximately 66% of the hydrogen case, and the current density of the accelerated beam current reached 190 A/m2. We have clearly found the lower limit of electron current ratio depending on the arc discharge power. Certainly, the extracted electron current ratio increased in deuterium operation. However, we have had no trouble on the beam line components.
- Open Access
- 9 August 2017
- Published by AIP Publishing
- Vol. 1869 (1) , 050004
Study of back streaming ion using a slot-type grounded grid in hydrogen negative-ion source
The properties of cesium (Cs) recycling due to back-streaming ions have been investigated using an optical emission spec-troscopy in the hydrogen negative ion (H−) source with a slot-type grounded grid (GG). The slot-type GG performed well to enhance the beam performance, and to reduce the thermal loading on GG by high transparency. We clearly observed increase of Cs optical emission intensity during beam extraction owing to the increase of the Cs ions sputtered from the back plate of the source due to the back-streaming positive hydrogen ions. Increase of Cs is closely related with the extracted H− current, but it does not depend on the beam energy. Recycling Cs from the back plate is deeply relevant to the perveance condition of the H− beam, and is minimized at the optimum perveance. Strong Cs recycling from the back plate owing to the back-streaming ions is promoted in the high perveance condition with large divergence, which is consistent with the numerical calculation for the distribution of back streaming ions. This high Cs recycling condition, however, is not suitable for safety beam operation with high energy beam. The output of beam power is saturated by the space charge limitation, and divergent beam is trapped in the grounded grid (GG), which may cause damage on the slot-type GG surface by high thermal loading as large as in the aperture-type GG.
- 9 August 2017
- Published by AIP Publishing
- Vol. 1869 (1) , 050004
Open AccessStudy of back streaming ion using a slot-type grounded grid in hydrogen negative-ion source
The properties of cesium (Cs) recycling due to back-streaming ions have been investigated using an optical emission spec-troscopy in the hydrogen negative ion (H−) source with a slot-type grounded grid (GG). The slot-type GG performed well to enhance the beam performance, and to reduce the thermal loading on GG by high transparency. We clearly observed increase of Cs optical emission intensity during beam extraction owing to the increase of the Cs ions sputtered from the back plate of the source due to the back-streaming positive hydrogen ions. Increase of Cs is closely related with the extracted H− current, but it does not depend on the beam energy. Recycling Cs from the back plate is deeply relevant to the perveance condition of the H− beam, and is minimized at the optimum perveance. Strong Cs recycling from the back plate owing to the back-streaming ions is promoted in the high perveance condition with large divergence, which is consistent with the numerical calculation for the distribution of back streaming ions. This high Cs recycling condition, however, is not suitable for safety beam operation with high energy beam. The output of beam power is saturated by the space charge limitation, and divergent beam is trapped in the grounded grid (GG), which may cause damage on the slot-type GG surface by high thermal loading as large as in the aperture-type GG.
- 25 November 2015
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (2) , 02B321
Improvement of accelerator of negative ion source on the Large Helical Device
To improve the performance of negative-ion based neutral beam injection on the Large Helical Device, the accelerator was modified on the basis of numerical investigations. A field limiting ring was installed on the upper side of a grounded grid (GG) support and a multi-slot GG was adopted instead of a multi-aperture GG. As a result, the voltage holding capability is improved and the heat load on the GG decreases by 40%. In addition, the arc efficiency is improved significantly only by replacing the GG.
- 25 November 2015
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (2) , 02B321
Improvement of accelerator of negative ion source on the Large Helical Device
To improve the performance of negative-ion based neutral beam injection on the Large Helical Device, the accelerator was modified on the basis of numerical investigations. A field limiting ring was installed on the upper side of a grounded grid (GG) support and a multi-slot GG was adopted instead of a multi-aperture GG. As a result, the voltage holding capability is improved and the heat load on the GG decreases by 40%. In addition, the arc efficiency is improved significantly only by replacing the GG.
- 14 January 2014
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 85 (2) , 02B131
Characteristics of plasma grid bias in large-scaled negative ion source
The electron density was measured at various bias voltages to understand how the plasma grid bias affects the electron near the plasma grid in large-scaled negative ion sources. It was found that the response of the electron to the bias voltage changes depending on negative ion production processes. The electron density remarkably decreases with increasing the bias voltage in the pure-volume plasma. On the other hand, the electron density depends on the bias voltage weakly in the Cs-seeded plasma. In addition, it was observed that the response of the co-extracted electron current to the bias voltage has similar trend to that of the electron density.
- 14 January 2014
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 85 (2) , 02B131
Characteristics of plasma grid bias in large-scaled negative ion source
The electron density was measured at various bias voltages to understand how the plasma grid bias affects the electron near the plasma grid in large-scaled negative ion sources. It was found that the response of the electron to the bias voltage changes depending on negative ion production processes. The electron density remarkably decreases with increasing the bias voltage in the pure-volume plasma. On the other hand, the electron density depends on the bias voltage weakly in the Cs-seeded plasma. In addition, it was observed that the response of the co-extracted electron current to the bias voltage has similar trend to that of the electron density.
- 1 February 2012
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 83 (2) , 02B113
Electron density measurement of cesium seeded negative ion source by surface wave probe
Electron density measurements of a large-scaled negative ion source were carried out with a surface wave probe. By comparison of the electron densities determined with the surface wave probe and a Langmuir probe, it was confirmed that the surface wave probe is highly available for diagnostic of the electron density in H− ion sources. In addition, it was found that the ratio of the electron density to the H− ion density dramatically decreases with increase of a bias voltage and the H− ions become dominant negative particles at the bias voltage of more than 6 V.
- 1 February 2012
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 83 (2) , 02B113
Electron density measurement of cesium seeded negative ion source by surface wave probe
Electron density measurements of a large-scaled negative ion source were carried out with a surface wave probe. By comparison of the electron densities determined with the surface wave probe and a Langmuir probe, it was confirmed that the surface wave probe is highly available for diagnostic of the electron density in H− ion sources. In addition, it was found that the ratio of the electron density to the H− ion density dramatically decreases with increase of a bias voltage and the H− ions become dominant negative particles at the bias voltage of more than 6 V.
- 26 September 2011
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1390 (1) , 684
Electron Strippers for Compact Neutron Generators
The next generation of compact tandem‐type DD or DT neutron generators requires a robust electron stripper with high charge exchange efficiency. In this study, stripping foils of various types were tested, and the to conversion efficiency, endurance to the heat load, and durability were investigated in terms of suitability in the tandem‐type neutron generator. In the experiments, a beam was accelerated to about 180 keV, passes through a stripping foil, and produces a mixed beam of and These ions were separated by an electric field, and detected by a movable Faraday cup to determine the conversion efficiency. The experimental results using thin foils of diamond‐like carbon, gold, and carbon nano‐tubes revealed issues on the robustness. As a new concept, a beam was injected onto a metal surface with an oblique angle, and reflected ions are detected. It was found that the conversion efficiency, fraction in the reflected particles, depends on the surface condition, with the maximum value of about 90%.- 26 September 2011
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1390 (1) , 684
Electron Strippers for Compact Neutron Generators
The next generation of compact tandem‐type DD or DT neutron generators requires a robust electron stripper with high charge exchange efficiency. In this study, stripping foils of various types were tested, and the to conversion efficiency, endurance to the heat load, and durability were investigated in terms of suitability in the tandem‐type neutron generator. In the experiments, a beam was accelerated to about 180 keV, passes through a stripping foil, and produces a mixed beam of and These ions were separated by an electric field, and detected by a movable Faraday cup to determine the conversion efficiency. The experimental results using thin foils of diamond‐like carbon, gold, and carbon nano‐tubes revealed issues on the robustness. As a new concept, a beam was injected onto a metal surface with an oblique angle, and reflected ions are detected. It was found that the conversion efficiency, fraction in the reflected particles, depends on the surface condition, with the maximum value of about 90%.- 26 September 2011
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1390 (1) , 367
Comparison of Optical Emission Spectroscopy and Cavity Ring-Down Spectroscopy in Large-Scaled Negative-Ion Source
Optical emission spectroscopy (OES) and cavity ring‐down spectroscopy (CRDS) systems are installed in a 1/3‐scaled negative hydrogen‐ion source at the National Institute for Fusion Science testbed to investigate the dynamics of ions in the extraction region near the plasma grid. The signal form of the ion density rapidly drops after beam extraction on applying a low‐bias voltage. A similar signal drop appears in the intensity of the hydrogen Balmer‐line emission measured by OES and is caused by decreasing atomic hydrogen produced by mutual neutralization effects between and Shot trend of the beam currents are similar to the density and in the extraction region, which increases twice as large immediately after Cs seeding. We observe a linear correlation between the density and the inclination of which allows for experimentally benchmarking the OES measurement with that of CRDS. Thus, this approach is used for estimating the density by OES in negative‐ion sources for high‐energy neutral beam injector.- 26 September 2011
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1390 (1) , 367
Comparison of Optical Emission Spectroscopy and Cavity Ring-Down Spectroscopy in Large-Scaled Negative-Ion Source
Optical emission spectroscopy (OES) and cavity ring‐down spectroscopy (CRDS) systems are installed in a 1/3‐scaled negative hydrogen‐ion source at the National Institute for Fusion Science testbed to investigate the dynamics of ions in the extraction region near the plasma grid. The signal form of the ion density rapidly drops after beam extraction on applying a low‐bias voltage. A similar signal drop appears in the intensity of the hydrogen Balmer‐line emission measured by OES and is caused by decreasing atomic hydrogen produced by mutual neutralization effects between and Shot trend of the beam currents are similar to the density and in the extraction region, which increases twice as large immediately after Cs seeding. We observe a linear correlation between the density and the inclination of which allows for experimentally benchmarking the OES measurement with that of CRDS. Thus, this approach is used for estimating the density by OES in negative‐ion sources for high‐energy neutral beam injector.