P. P. Deichuli
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
P. P. Deichuli has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
A. A. Ivanov
Budker Institute of Nuclear Physics of the Siberian Branch of the Russian Academy of Sciences, Novosibirsk, Russia
4 shared publicationsA. Abdrashitov
Budker Institute of Nuclear Physics , 630090 Novosibirsk, Russia
1 shared publicationA. Dranichnikov
Budker Institute of Nuclear Physics , 630090 Novosibirsk, Russia
1 shared publicationA. G. Abdrashitov
Budker Institute of Nuclear Physics of Siberian Branch Russian Academy of Sciences, Novosibirsk, Russia
1 shared publicationA. Gorbovsky
Budker Institute of Nuclear Physics , 630090 Novosibirsk, Russia
1 shared publicationA. I. Gorbovsky
Budker Institute of Nuclear Physics of Siberian Branch Russian Academy of Sciences, Novosibirsk, Russia
1 shared publication
Latest Publications
- 1 July 2021
- Published by Pleiades Publishing Ltd in Plasma Physics Reports
- Vol. 47 (7) , 652-660
Doppler Spectroscopy Measurements of Neutral Hydrogen–Deuterium Beam
Production of neutral beams consisting of the mixed hydrogen isotopes is of interest for the purposes of diagnostics, since it enables us to study the relaxation process of fast ions trapped in plasma using the neutron diagnostics. In addition, the injection of mixed deuterium–tritium beams for heating and sustaining the plasma could greatly simplify the expensive systems for isotope separation in fusion reactors. In this work, the Doppler spectroscopy technique is used to experimentally determine the fractional content of ions with different masses in the ion source beam consisting of the mixed hydrogen isotopes (hydrogen–deuterium beam). The experience acquired in this field is proposed to be further used to optimize the conditions for plasma generation in the ion source in order to obtain an ion beam with the mixed isotope composition and specific characteristics required for various applications.
- 1 July 2021
- Published by Pleiades Publishing Ltd in Plasma Physics Reports
- Vol. 47 (7) , 652-660
Doppler Spectroscopy Measurements of Neutral Hydrogen–Deuterium Beam
Production of neutral beams consisting of the mixed hydrogen isotopes is of interest for the purposes of diagnostics, since it enables us to study the relaxation process of fast ions trapped in plasma using the neutron diagnostics. In addition, the injection of mixed deuterium–tritium beams for heating and sustaining the plasma could greatly simplify the expensive systems for isotope separation in fusion reactors. In this work, the Doppler spectroscopy technique is used to experimentally determine the fractional content of ions with different masses in the ion source beam consisting of the mixed hydrogen isotopes (hydrogen–deuterium beam). The experience acquired in this field is proposed to be further used to optimize the conditions for plasma generation in the ion source in order to obtain an ion beam with the mixed isotope composition and specific characteristics required for various applications.
- 21 September 2018
- Published by AIP Publishing
- Vol. 2011 (1) , 080002
RF driven multiaperture surface-plasma negative ion source: Beam formation and transport through LEBT
Negative-ion based neutral bean injector is under development at Budker Institute of Nuclear Physics. It’s essential feature is beam transport from the multiaperture source to a single-aperture accelerating tube through a low energy beam transport line (LEBT). This scheme permits to purify the beam from the co-streaming fluxes of fast hydrogen atoms, gas molecules, cesium vapor. As a result, the loading on the accelerating tube by harmful co-streaming and secondary particles is considerably reduced. It will enable more stable operation of the negative ion beam accelerator. Experimental study of long-pulsed 0.8 -1.2 A, 85-100 keV negative ion beam formation and transport through the LEBT to the distant calorimeter is described. The parameters of the transported beam were electrically measured in the LEBT center at distance 1.6 m by the movable Faraday cup and at the LEBT exit (at distance 3.5 m from the source) - by the multisection beam calorimeter. The efficiency of beam transport vs various source and LEBT parameters is discussed.
- 21 September 2018
- Published by AIP Publishing
- Vol. 2011 (1) , 080002
RF driven multiaperture surface-plasma negative ion source: Beam formation and transport through LEBT
Negative-ion based neutral bean injector is under development at Budker Institute of Nuclear Physics. It’s essential feature is beam transport from the multiaperture source to a single-aperture accelerating tube through a low energy beam transport line (LEBT). This scheme permits to purify the beam from the co-streaming fluxes of fast hydrogen atoms, gas molecules, cesium vapor. As a result, the loading on the accelerating tube by harmful co-streaming and secondary particles is considerably reduced. It will enable more stable operation of the negative ion beam accelerator. Experimental study of long-pulsed 0.8 -1.2 A, 85-100 keV negative ion beam formation and transport through the LEBT to the distant calorimeter is described. The parameters of the transported beam were electrically measured in the LEBT center at distance 1.6 m by the movable Faraday cup and at the LEBT exit (at distance 3.5 m from the source) - by the multisection beam calorimeter. The efficiency of beam transport vs various source and LEBT parameters is discussed.
- 1 January 2016
- Published by AIP Publishing
Multi-second neutral beam injector (60kV, 6A) for plasma diagnostics in the upgraded T-15 device
A diagnostic neutral beam injector DINA-KI60 has been developed and produced for upgraded T-15 tokamak (Kurchatov Institute, Moscow). The system will be primarily used for measurement of the ion temperature by charge-exchange recombination spectroscopy (CXRS), for magnetic field measurements via motional Stark effect (MSE) and investigation of plasma turbulence by Beamemission spectroscopy (BES). The ion source provides 60 keV, 6 A hydrogen beam with low angular divergence less than 10 mrad. Ions are extracted from a plasma created by an arc-discharge source with cold cathode and, after accelerating and focusing, are neutralized in a gas target. The extracted beam has about 86% of full energy specie. The grids of ion optical system are spherically curved providing geometric focusing of the beam at a distance 4 m. Diagnostic neutral beam has been successfully tested at Budker Institute of Nuclear Physics at 2 seconds pulse duration with modulation of the beam (duty ratio from 1:1 to 1:3).
- 1 January 2016
- Published by AIP Publishing
Multi-second neutral beam injector (60kV, 6A) for plasma diagnostics in the upgraded T-15 device
A diagnostic neutral beam injector DINA-KI60 has been developed and produced for upgraded T-15 tokamak (Kurchatov Institute, Moscow). The system will be primarily used for measurement of the ion temperature by charge-exchange recombination spectroscopy (CXRS), for magnetic field measurements via motional Stark effect (MSE) and investigation of plasma turbulence by Beamemission spectroscopy (BES). The ion source provides 60 keV, 6 A hydrogen beam with low angular divergence less than 10 mrad. Ions are extracted from a plasma created by an arc-discharge source with cold cathode and, after accelerating and focusing, are neutralized in a gas target. The extracted beam has about 86% of full energy specie. The grids of ion optical system are spherically curved providing geometric focusing of the beam at a distance 4 m. Diagnostic neutral beam has been successfully tested at Budker Institute of Nuclear Physics at 2 seconds pulse duration with modulation of the beam (duty ratio from 1:1 to 1:3).
- 1 February 2012
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 83 (2) , 02B114
Commissioning of heating neutral beams for COMPASS-D tokamak
Two neutral beam injectors have been developed for plasma heating on COMPASS-D tokamak (Institute of Plasma Physics, Prague). The 4-electrodes multihole ion-optical system with beam focusing was chosen to provide the low divergence 300 kW power in both deuterium and hydrogen atoms. The accelerating voltage is 40 kV at extracted ion current up to 15 A. The power supply system provides the continuous and modulated mode of the beam injection at a maximal pulse length 300 ms. The optimal arrangement of the cryopanels and the beam duct elements provides sufficiently short-length beamline which reduces the beam losses. The evolution of the impurities and molecular fraction content is studied in the process of the high voltage conditioning of the newly made ion sources. Two injectors of the same type have been successfully tested and are ready for operation at tokamak in IPP, Prague.
- 1 February 2012
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 83 (2) , 02B114
Commissioning of heating neutral beams for COMPASS-D tokamak
Two neutral beam injectors have been developed for plasma heating on COMPASS-D tokamak (Institute of Plasma Physics, Prague). The 4-electrodes multihole ion-optical system with beam focusing was chosen to provide the low divergence 300 kW power in both deuterium and hydrogen atoms. The accelerating voltage is 40 kV at extracted ion current up to 15 A. The power supply system provides the continuous and modulated mode of the beam injection at a maximal pulse length 300 ms. The optimal arrangement of the cryopanels and the beam duct elements provides sufficiently short-length beamline which reduces the beam losses. The evolution of the impurities and molecular fraction content is studied in the process of the high voltage conditioning of the newly made ion sources. Two injectors of the same type have been successfully tested and are ready for operation at tokamak in IPP, Prague.
- 1 March 2003
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 74 (3) , 1592-1595
Measurements of the radial profile of magnetic field in the Gas-Dynamic Trap using a motional Stark effect diagnostic
- 1 March 2003
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 74 (3) , 1592-1595
Measurements of the radial profile of magnetic field in the Gas-Dynamic Trap using a motional Stark effect diagnostic