Matthew S. Taubman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Matthew S. Taubman has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Usdoe
2 shared publicationsAnton S. Sinkov
Pacific Northwest National Laboratory (PNNL), Richland, WA (United States)
1 shared publication- Brian E. Brumfield
Pacific Northwest National Laboratory, Richland WA 99352, USA
1 shared publication Christian R. Boutan
Pacific Northwest National Laboratory (PNNL), Richland, WA (United States)
1 shared publication- Mark C. Phillips
Pacific Northwest National Laboratory, United States
1 shared publication Noah S. Solomon-Oblath
Pacific Northwest National Laboratory (PNNL), Richland, WA (United States)
1 shared publication
Latest Publications
- Open Access
- 29 October 2020
- Published by Office of Scientific and Technical Information (OSTI)
Axion Dark Matter Experiment Cavity Locking; System Development and Testing
This report documents the comparison of two frequency locking techniques for the four-cavity system under development for run 2A of the Axion Dark Matter eXperiment (ADMX). This report covers the requirements and technical challenges facing both of these techniques, a summary of tests performed at the University of Florida in late 2017 / early 2018 in order to compare them, and the final outcome and decision based on these tests and subsequent analysis.
- 29 October 2020
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessAxion Dark Matter Experiment Cavity Locking; System Development and Testing
This report documents the comparison of two frequency locking techniques for the four-cavity system under development for run 2A of the Axion Dark Matter eXperiment (ADMX). This report covers the requirements and technical challenges facing both of these techniques, a summary of tests performed at the University of Florida in late 2017 / early 2018 in order to compare them, and the final outcome and decision based on these tests and subsequent analysis.
- Open Access
- 13 November 2019
- Published by Office of Scientific and Technical Information (OSTI)
Ultrasonic Modem
This report details the demonstrated operation of a dual-ultrasonic link that transmits ultrasonic power through stainless steel of up to 36 inches in thickness, harvests and stores this energy, then uses it to transmit data back through the metal to be received and recorded externally. This exploratory demonstration funded by DOE office of Environmental Management shows a proof of principal for passing power and data through such things as vessel or container walls using ultrasonic techniques where direct access is impossible, without needing to use wireless technologies, magnetic fields, or optical access. This technology opens up the possibility of interrogating sensor systems placed within closed vessels, or pieces of industrial machinery without the need for wires, holes in the wall, or other intrusive means, and also without the need for batteries or other power source within the closed vessel.
- 13 November 2019
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessUltrasonic Modem
This report details the demonstrated operation of a dual-ultrasonic link that transmits ultrasonic power through stainless steel of up to 36 inches in thickness, harvests and stores this energy, then uses it to transmit data back through the metal to be received and recorded externally. This exploratory demonstration funded by DOE office of Environmental Management shows a proof of principal for passing power and data through such things as vessel or container walls using ultrasonic techniques where direct access is impossible, without needing to use wireless technologies, magnetic fields, or optical access. This technology opens up the possibility of interrogating sensor systems placed within closed vessels, or pieces of industrial machinery without the need for wires, holes in the wall, or other intrusive means, and also without the need for batteries or other power source within the closed vessel.
- Open Access
Rapid and Sensitive Quantification of Isotopic Mixtures Using a Rapidly-Swept External Cavity Quantum Cascade Laser
A rapidly-swept external-cavity quantum cascade laser with an open-path Herriott cell is used to quantify gas-phase chemical mixtures of D2O and HDO at a rate of 40 Hz (25-ms measurement time). The chemical mixtures were generated by evaporating D2O liquid near the open-path Herriott cell, allowing the H/D exchange reaction with ambient H2O to produce HDO. Fluctuations in the ratio of D2O and HDO on timescales of 2O and HDO, respectively, with a 127-m optical path. These NECs are improved to 23.0 and 24.0 ppbv with a 1-s averaging time for D2O and HDO, respectively. NECs 2O, 1,1,1,2–tetrafluoroethane (F134A), CH4, acetone and SO2 for a 25-ms measurement time. The isotopic precision for measurement of the [D2O]/[HDO] concentration ratio of 33‰ and 5‰ is calculated for the current experimental conditions for measurement times of 25 ms and 1 s, respectively.
Open AccessRapid and Sensitive Quantification of Isotopic Mixtures Using a Rapidly-Swept External Cavity Quantum Cascade Laser
A rapidly-swept external-cavity quantum cascade laser with an open-path Herriott cell is used to quantify gas-phase chemical mixtures of D2O and HDO at a rate of 40 Hz (25-ms measurement time). The chemical mixtures were generated by evaporating D2O liquid near the open-path Herriott cell, allowing the H/D exchange reaction with ambient H2O to produce HDO. Fluctuations in the ratio of D2O and HDO on timescales of 2O and HDO, respectively, with a 127-m optical path. These NECs are improved to 23.0 and 24.0 ppbv with a 1-s averaging time for D2O and HDO, respectively. NECs 2O, 1,1,1,2–tetrafluoroethane (F134A), CH4, acetone and SO2 for a 25-ms measurement time. The isotopic precision for measurement of the [D2O]/[HDO] concentration ratio of 33‰ and 5‰ is calculated for the current experimental conditions for measurement times of 25 ms and 1 s, respectively.
- 1 January 2013
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 84 (1) , 016103
Note: Switch-mode hybrid current controllers for quantum cascade lasers
Chemical sensing in the mid-infrared has been revolutionized by the advent of quantum cascade lasers. Their higher current and voltage demands compared to laser diodes however, negatively impact size, weight, and power footprint for fieldable systems, particularly in hot environments. This Note presents a switch-mode/linear hybrid controller, furnishing drive currents up to 2 A at compliance voltages up to 15 V, with output noise near levels determined by shot and Johnson contributions from within the linear regulator, from frequencies below 100 Hz to the switching frequency. Current modulation from near 0 to 1.8 A is also demonstrated at frequencies up to a kilohertz.
- 1 January 2013
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 84 (1) , 016103
Note: Switch-mode hybrid current controllers for quantum cascade lasers
Chemical sensing in the mid-infrared has been revolutionized by the advent of quantum cascade lasers. Their higher current and voltage demands compared to laser diodes however, negatively impact size, weight, and power footprint for fieldable systems, particularly in hot environments. This Note presents a switch-mode/linear hybrid controller, furnishing drive currents up to 2 A at compliance voltages up to 15 V, with output noise near levels determined by shot and Johnson contributions from within the linear regulator, from frequencies below 100 Hz to the switching frequency. Current modulation from near 0 to 1.8 A is also demonstrated at frequencies up to a kilohertz.