JCJinil Chung

Jinil Chung

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jinil Chung has a total of 38 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Considerations of the q-profile control in KSTAR for advanced tokamak operation scenarios

    by J. Chung, J. Ko, S.-H. Hahn, H. S. Kim, S. J. Wang

    The q-profile control is essential for tokamaks exploring the advanced tokamak scenarios, which is expected to be able to provide a possible route toward a steady-state high performance operation in a fully non-inductive current drive state. This is because the pressure and current profiles must remain optimal for the scenario during the injection of large amounts of heating and current drive. Here, essential tools for the q-profile control are the motional Stark effect diagnostic for measuring the radial magnetic pitch angle profile and a state-of-the-art plasma control system. The pulse duration of the H-mode discharge at KSTAR has been extended year by year with improved control performance, and the experiment of internal transport barrier (ITB) formation in a weakly reversed q-profile with a marginal neutral beam injection majority heating successfully demonstrated that the ITB is an alternative candidate to achieve a high performance regime in KSTAR. These recent achievements are attributed to reliable profile measurement, which means that profile feedback control has become a necessary step to ensure a robust and reliable approach to advanced scenarios as the next step of research in KSTAR. In this paper, we discuss the technical and conceptual requirements for q-profile control according to the upgrade plan for heating and current drive systems in the coming years.


  • Formation of the internal transport barrier in KSTAR

    by J. Chung, H.S. Kim, Y.M. Jeon, J. Kim, M.J. Choi, J. Ko, K.D. Lee, H.H. Lee, S. Yi, J.M. Kwon, et al.


  • Initial operation of a newly developed multichord motional Stark effect diagnostic in KSTAR

    by J. Chung, J. Ko, H. Wi, M. Messmer, S. Schenkelaars, M. Scheffer, R. J. E. Jaspers

    A photo-elastic modulator based 25-chord motional Stark effect (MSE) diagnostic has been successfully developed and commissioned in Korea Superconducting Tokamak Advanced Research. The diagnostic measures the radial magnetic pitch angle profile of the Stark splitting of a D-alpha line at 656.1 nm by the electric field associated with the neutral deuterium heating beam. A tangential view of the neutral beam provides a good spatial resolution of 1–3 cm for covering the major radius from 1.74 m to 2.28 m, and the time resolution is achieved at 10 ms. An in-vessel calibration before the vacuum closing as well as an in situ calibration during the tokamak operation was performed by means of specially designed polarized lighting sources. In this work, we present the final design of the installed MSE diagnostic and the first results of the commissioning.


  • Motional Stark effect diagnostics for KSTAR

    by J. Chung, J. Ko, J. Howard, C. Michael, G. von Nessi, A. Thorman, M. F. M. De Bock

    The motional Stark effect (MSE) diagnostic is used to measure the radial magnetic pitch-angle profile in neutral-beam-heated plasmas. The diagnostic relies upon the measurement of the polarization...


  • Instrumentation for a multichord motional Stark effect diagnostic in KSTAR

    by J. Chung, J. Ko, M. F. M. De Bock, R. J. E. Jaspers

    The motional Stark effect (MSE) diagnostic is used to measure the radial magnetic pitch angle profile in neutral beam heated plasmas. This information is used to calculate the safety factor, q, with magnetic equilibrium reconstruction codes such as EFIT. The MSE diagnostic is important during active shaping of the q profile to optimize confinement and stability, and it has become a key diagnostic in high performance tokamaks. A multichord photo-elastic modulator (PEM) based MSE system is being developed for a real-time plasma current profile control in Korea Superconducting Tokamak Advanced Research (KSTAR). The PEM-based approach is a standard method that measures the polarization direction of a single Stark line with narrow tunable bandpass filters. A tangential view of the heating beam provides good spatial resolution of 1–3 cm, which provides an opportunity to install 25 spatial channels spanning the major radius from 1.74 m to 2.84 m. Application of real-time control is a long-term technical goal after commissioning the diagnostic in KSTAR, which is expected in 2015. In this paper, we describe the design of this newly-constructed multichord MSE diagnostic in KSTAR.


  • Real-time MSE measurements for current profile control on KSTAR

    by M. F. M. De Bock, D. Aussems, R. Huijgen, M. Scheffer, J. Chung

    To step up from current day fusion experiments to power producing fusion reactors, it is necessary to control long pulse, burning plasmas. Stability and confinement properties of tokamak fusion reactors are determined by the current or q profile. In order to control the q profile, it is necessary to measure it in real-time. A real-time motional Stark effect diagnostic is being developed at Korean Superconducting Tokamak for Advanced Research for this purpose. This paper focuses on 3 topics important for real-time measurements: minimize the use of ad hoc parameters, minimize external influences and a robust and fast analysis algorithm. Specifically, we have looked into extracting the retardance of the photo-elastic modulators from the signal itself, minimizing the influence of overlapping beam spectra by optimizing the optical filter design and a multi-channel, multiharmonic phase locking algorithm.


  • Characterization of a linear device developed for research on advanced plasma imaging and dynamics

    by J. Chung, K. D. Lee, D. C. Seo, Y. U. Nam, M. C. Choi

    Within the scope of long term research on imaging diagnostics for steady-state plasmas and understanding of edge plasma physics through diagnostics with conventional spectroscopic methods, we have constructed a linear electron cyclotron resonance (ECR) plasma device named Research on Advanced Plasma Imaging and Dynamics (RAPID). It has a variety of axial magnetic field profiles provided by eight water-cooled magnetic coils and two dc power supplies. The positions of the magnetic coils are freely adjustable along the axial direction and the power supplies can be operated with many combinations of electrical wiring to the coils. Here, a 6 kW 2.45 GHz magnetron is used to produce steady-state hydrogen, helium, and argon plasmas with central magnetic fields of 875 and/or 437.5 G (second harmonic). In order to achieve the highest possible plasma performance within the limited input parameters, wall conditioning experiments were carried out. Chamber bake-out was achieved with heating coils that were wound covering the vessel, and long-pulse electron cyclotron heating discharge cleaning was also followed after 4 days of bake-out. A uniform bake-out temperature (150 °C) was achieved by wrapping the vessel in high temperature thermal insulation textile and by controlling the heating coil current using a digital control system. The partial pressure changes were observed using a residual gas analyzer, and a total system pressure of 5×10−8 Torr was finally reached. Diagnostic systems including a millimeter-wave interferometer, a high resolution survey spectrometer, a Langmuir probe, and an ultrasoft x-ray detector were used to provide the evidence that the plasma performance was improved as we desired. In this work, we present characterization of the RAPID device for various system conditions and configurations.

  • Descriptions of a linear device developed for research on advanced plasma imaging and dynamics

    by J. Chung, K. D. Lee, D. C. Seo, Y. U. Nam, W. H. Ko, J. H. Lee, M. C. Choi

    The research on advanced plasma imaging and dynamics (RAPID) device is a newly developed linear electron cyclotron resonance (ECR) plasma device. It has a variety of axial magnetic field profiles provided by eight water-cooled magnetic coils and two dc power supplies. The positions of the magnetic coils are freely adjustable along the axial direction and the power supplies can be operated with many combinations of electrical wiring to the coils. A 6 kW 2.45 GHz magnetron is used to produce steady-state ECR plasmas with central magnetic fields of 875 and/or 437.5 G (second harmonic). The cylindrical stainless steel vacuum chamber is 300 mm in diameter and 750 mm in length and has eight radial and ten axial ports including 6-in. and 8-in. viewing windows for heating and diagnostics. Experimental observation of ECR plasma heating has been recently carried out during the initial plasma operation. The main diagnostic systems including a 94 GHz heterodyne interferometer, a high-resolution 25 channel one-dimensional array spectrometer, a single channel survey spectrometer, and an electric probe have been also prepared. The RAPID device is a flexible simulator for the understanding of tokamak edge plasma physics and new diagnostic system development. In this work, we describe the RAPID device and initial operation results.


  • Installation of a fast framing visible camera on KSTAR

    by Jinil Chung, Deok Kyo Lee, Dongcheol Seo, Myoung Choul Choi

    Visible camera technologies have made remarkable progress in recent years, and the fast camera has proven itself to be a capable imaging diagnostic in studies of specific fusion plasma issues such as the start-up physics, plasma wall interactions, edge-localized modes, and disruptions. For the purpose of favorable visible imaging, a fast framing camera has recently been installed on the Korea Superconducting Tokamak Advanced Research (KSTAR) device. The camera uses a complementary metal-oxide semiconductor detector with a maximum resolution of 1280×1024 at 1000frames∕s (fps) and a minimum resolution of 1280×16 at 64kfps. A 2-m-long viewport having a novel optical rail system was installed on a tangential port to view the tokamak interior. The system is fully controlled from the main control room and protected by a shutter from deposits. To verify that the camera electronics are safe from the high magnetic field and its rapid time variation, possible influences are considered theoretically and experimentally. In this work, we present the design and installation of the fast camera system on the KSTAR device with discussions on the field variation effect issues.


  • In-vessel visible inspection system on KSTAR

    by Jinil Chung, D. C. Seo

    To monitor the global formation of the initial plasma and damage to the internal structures of the vacuum vessel, an in-vessel visible inspection system has been installed and operated on the Korean superconducting tokamak advanced research (KSTAR) device. It consists of four inspection illuminators and two visible/H-alpha TV cameras. Each illuminator uses four 150W metal-halide lamps with separate lamp controllers, and programmable progressive scan charge-coupled device cameras with 1004×1004 resolution at 48frames∕s and a resolution of 640×480 at 210frames∕s are used to capture images. In order to provide vessel inspection capability under any operation condition, the lamps and cameras are fully controlled from the main control room and protected by shutters from deposits during plasma operation. In this paper, we describe the design and operation results of the visible inspection system with the images of the KSTAR Ohmic discharges during the first plasma campaign.