Klaus Jürgen Engel
Research Subjects
Klaus Jürgen Engel has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Günter Zeitler
2 shared publications- Axel Thran
Philips Research Europe—Hamburg, Digital Imaging, Röntgenstrasse 24–26, D-22335 Hamburg, Germany
1 shared publication - Bernhard Brendel
Department of Image Formation and Medical Image Acquisition, Philips Research, 22335 Hamburg, Germany
1 shared publication - Christian Bäumer1 shared publication
Christoph Hermann
1 shared publicationChristoph Herrmann
1 shared publication
Latest Publications
- 1 August 2011
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 648, S259-S264
Preclinical spectral computed tomography of gold nano-particles
- 1 August 2011
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 648, S259-S264
Preclinical spectral computed tomography of gold nano-particles
- 14 October 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 57 (5) , 2995
Correction to "Status of Direct Conversion Detectors for Medical Imaging With X-Rays" [Aug 09 1800-1809]
In the above titled paper (ibid., vol. 56, no. 4, pp. 1800-1809, Aug. 09), an error appeared in Table III. A corrected version of Table III is presented here.
- 14 October 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 57 (5) , 2995
Correction to "Status of Direct Conversion Detectors for Medical Imaging With X-Rays" [Aug 09 1800-1809]
In the above titled paper (ibid., vol. 56, no. 4, pp. 1800-1809, Aug. 09), an error appeared in Table III. A corrected version of Table III is presented here.
- 26 December 2007
- Published by Wiley in Medical Physics
- Vol. 35 (1) , 318-332
X‐ray scattering in single‐ and dual‐source CT
For medical imaging applications, such as cardiac imaging, dual‐source computed tomography (CT) improves the temporal resolution by the simultaneous use of two cone beams, which acquire twice as many projections as single‐source CT does within the same time interval. Besides this advantage, a drawback of such a system is additional x‐ray scatter originating from the extra (cross‐illuminating) cone beam. In this work, a comparison with single‐source CT images is performed under same‐dose conditions for two different thorax phantoms, and for different cone beam angles corresponding to a coverage of 20, 40, 80, and 160 mm on the rotation axis ( coverage). As a general result, the HU‐magnitude of scatter‐induced streak and cupping artifacts scale almost proportional to the illuminated volume. In dual‐source CT, cross scatter induces a further factor of almost 2 in the scaling of artifacts in comparison to single‐source CT. For all examined systems, the scatter‐induced noise reduces the contrast‐to‐noise ratio (CNR). In the case of an ideal scatter correction, the CNR is reduced even more, but contrast and CNR can be restored by an additional x‐ray dose. With a 32‐slice single‐source CT ( overage of 20 mm) taken as a reference, a corresponding dual‐source CT requires more dose to maintain the same CNR. A CT system with a coverage of 40, 80, and 160 mm requires , , and more dose in a single‐source configuration, respectively, and , , and more dose in a dual‐source configuration, respectively. In conclusion, a dual‐source CT is comparable to a single‐source CT with twice the coverage concerning image degradation by scatter.
- 26 December 2007
- Published by Wiley in Medical Physics
- Vol. 35 (1) , 318-332
X‐ray scattering in single‐ and dual‐source CT
For medical imaging applications, such as cardiac imaging, dual‐source computed tomography (CT) improves the temporal resolution by the simultaneous use of two cone beams, which acquire twice as many projections as single‐source CT does within the same time interval. Besides this advantage, a drawback of such a system is additional x‐ray scatter originating from the extra (cross‐illuminating) cone beam. In this work, a comparison with single‐source CT images is performed under same‐dose conditions for two different thorax phantoms, and for different cone beam angles corresponding to a coverage of 20, 40, 80, and 160 mm on the rotation axis ( coverage). As a general result, the HU‐magnitude of scatter‐induced streak and cupping artifacts scale almost proportional to the illuminated volume. In dual‐source CT, cross scatter induces a further factor of almost 2 in the scaling of artifacts in comparison to single‐source CT. For all examined systems, the scatter‐induced noise reduces the contrast‐to‐noise ratio (CNR). In the case of an ideal scatter correction, the CNR is reduced even more, but contrast and CNR can be restored by an additional x‐ray dose. With a 32‐slice single‐source CT ( overage of 20 mm) taken as a reference, a corresponding dual‐source CT requires more dose to maintain the same CNR. A CT system with a coverage of 40, 80, and 160 mm requires , , and more dose in a single‐source configuration, respectively, and , , and more dose in a dual‐source configuration, respectively. In conclusion, a dual‐source CT is comparable to a single‐source CT with twice the coverage concerning image degradation by scatter.