GCGuang-Pei Chen

Guang-Pei Chen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Guang-Pei Chen has a total of 36 co-authors. Here are the top co-authors by number of shared publications:

  • X. Allen Li

    Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, WI 53226

    5 shared publications
  • An Tai

    Radiation Oncology Medical College of Wisconsin Milwaukee USA

    3 shared publications
  • Ergun Ahunbay

    Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin 53226

    2 shared publications
  • Lindsay Puckett

    Radiation Oncology Medical College of Wisconsin Milwaukee USA

    2 shared publications
  • Sara Lim

    Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, WI 53226

    2 shared publications
  • Baolin Qu

    Department of Radiation Oncology, PLA General Hospital, Beijing, China

    1 shared publication

Latest Publications

  • Open Access

    Routine physics work efficacy and efficiency improvement through a shared‐duty physicist‐of‐the‐day model in a multi‐hospital radiation oncology network

    by Guang‐Pei Chen, Douglas E. Prah, Eric S. Paulson

    Background: Large multi‐hospital radiation oncology networks often rely on site‐exclusive physicist coverage models that can lead to imbalanced workload distribution, inconsistent task execution, communication fragmentation, and vulnerability to delayed or missed quality checks. Increasing clinical complexity and distributed staffing models necessitate operational strategies that improve efficiency, standardization, and safety across geographically separated sites. Purpose: To describe the implementation of a shared‐duty physicist‐of‐the‐day (POD) model supported by a real‐time operational dashboard and to evaluate its impact on workload distribution, task efficiency, and safety metrics across a multi‐hospital radiation oncology network. Methods: A structural transition from a site‐exclusive to a shared‐duty POD model was implemented in our institution—a four‐site academic radiation oncology system. A custom application, RadOncStatusBoard, was developed using structured query language (SQL)‐based integration with the Mosaiq Record & Verify system to aggregate real‐time patient appointments, treatment progress, quality checklist (QCL) items, and weekly chart check (WCC) eligibility. Microsoft Teams channels were used for daily communication and task coordination. Operational data from two matched 21‐month intervals—before and after POD restructuring—were extracted using SQL. Evaluated metrics included task volumes, claim times, completion times, WCC performance, billing accuracy, and dosimetry‐related Radiation Oncology Incident Learning System (RO‐ILS) event reporting. Right‐skewed distributions were summarized using medians and interquartile ranges (IQR). Surveys of physicists and dosimetrists were performed to assess end‐user perceptions of workflow and safety. Results: Workload balance improved across all task categories, with substantial decreases in main‐to‐satellite task ratios (e.g., the ratio for chart close decreased from 1.91 to 1.27). Task claim and completion times decreased markedly at both main and satellite locations (e.g., chart‐close claim time decreased from 36.8 to 6.2 min at the main campus). WCC completion improved from 97.7% to 99.9%, and WCC charge capture increased from 96.1% to 99.4%. The proportion of dosimetry‐related RO‐ILS events decreased numerically from 31.0% to 26.7% ( p = 0.339). Survey responses from physicists and dosimetrists indicated improved workflow clarity, communication, workload balance, and perceived patient safety. Conclusions: Implementation of a shared‐duty POD model improved workload balance, enhanced operational efficiency, and strengthened routine safety processes across a multi‐site radiation oncology program. Integration of a real‐time operational dashboard, standardized communication pathways, and structured task‐claiming workflows enabled measurable gains in responsiveness, compliance, and perceived safety culture.

  • Open Access

    Real-Time Motion Management for a Small Target in the Right Lower Lobe With Large Tumor Motion Using Radixact Synchrony: A Case Report

    by Guang-Pei Chen, An Tai, Lindsay Puckett, Eric Paulson

    Accurate real-time motion tracking is crucial for effective stereotactic body radiotherapy (SBRT) in lung cancer patients, particularly those with significant tumor motion. Techniques to reduce tumor motion, such as abdominal compression, breath hold, or respiratory gating, are often uncomfortable or result in longer treatment times. The Radixact Synchrony system (Accuray Inc., Sunnyvale, California, United States) enables continuous adaptation to tumor motion without the need for implanted fiducials. We report the case of a patient with a small target in the right lower lobe (RLL) with large tumor motion managed using Radixact Synchrony, highlighting treatment planning, delivery accuracy, and clinical outcomes.


  • Open Access

    Clinical Implementation and Initial Experience of Real-Time Motion Tracking With Jaws and Multileaf Collimator During Helical Tomotherapy Delivery

    by Guang-Pei Chen, An Tai, Lindsay Puckett, Elizabeth Gore, Sara Lim, Timothy Keiper, Candice Johnstone, Monica Shukla, Colleen Lawton, X. Allen Li


  • Open Access

    Technical Note: Comprehensive performance tests of the first clinical real‐time motion tracking and compensation system using MLC and jaws

    by Guang‐Pei Chen, An Tai, Timothy D. Keiper, Sara Lim, X. Allen Li

    Purpose: To evaluate the performance of the first clinical real‐time motion tracking and compensation system using multileaf collimator (MLC) and jaws during helical tomotherapy delivery.Methods: Appropriate mechanical and dosimetry tests were performed on the first clinical real‐time motion tracking system (Synchrony on Radixact, Accuray Inc) recently installed in our institution. kV radiography dose was measured by CTDIw using a pencil chamber. Changes of beam characteristics with jaw offset and MLC leaf shift were evaluated. Various dosimeters and phantoms including A1SL ion chamber (Standard Imaging), Gafchromic EBT3 films (Ashland), TomoPhantom (Med Cal), ArcCheck (Sun Nuclear), Delta4 (ScandiDos), with fiducial or high contrast inserts, placed on two dynamical motion platforms (CIRS dynamic motion‐CIRS, Hexamotion‐ScandiDos), were used to assess the dosimetric accuracy of the available Synchrony modalities: fiducial tracking with nonrespiratory motion (FNR), fiducial tracking with respiratory modeling (FR), and fiducial free (e.g., lung tumor tracking) with respiratory modeling (FFR). Motion detection accuracy of a tracking target, defined as the difference between the predicted and instructed target positions, was evaluated with the root mean square (RMS). The dose accuracy of motion compensation was evaluated by verifying the dose output constancy and by comparing measured and planned (predicted) three‐dimensional (3D) dose distributions based on gamma analysis.Results: The measured CTDIw for a single radiograph with a 120 kVp and 1.6 mAs protocol was 0.084 mGy, implying a low imaging dose of 8.4 mGy for a typical Synchrony motion tracking fraction with 100 radiographs. The dosimetric effect of the jaw swing or MLC leaf shift was minimal on depth dose (<0.5%) and was <2% on both beam profile width and output for typical motions. The motion detection accuracies, that is, RMS, were 0.84, 1.13, and 0.48 mm for FNR, FR, and FFR, respectively, well within the 1.5 mm recommended tolerance. Dose constancy with Synchrony was found to be within 2%. The gamma passing rates of 3D dose measurements for a variety of Synchrony plans were well within the acceptable level.Conclusions: The motion tracking and compensation using kV radiography, MLC shifting, and jaw swing during helical tomotherapy delivery was tested to be mechanically and dosimetrically accurate for clinical use.


  • Radiation-induced CT number changes in GTV and parotid glands during the course of radiation therapy for nasopharyngeal cancer

    by Shouping Xu, Zhaoxia Wu, Cungeng Yang, Lin Ma, Baolin Qu, Guangpei Chen, Weirong Yao, Shi Wang, Yaqiang Liu, X. Allen Li

    To investigate the changes in CT number (CTN) in gross tumor volume (GTV) and organs at risk (OARs) during the course of radiation therapy (RT) for nasopharyngeal cancer (NPC). Daily megavoltage (MV) CT data collected from 30 NPC patients treated with a prescription dose of 70 Gy in 30-33 fractions using helical tomotherapy were retrospectively analyzed. The contours of GTV and OARs on daily MVCTs were obtained by populating the planning contours from planning CT to daily MVCTs with manual editing if necessary. The changes of GTV and OAR volumes and the histograms of CTN in the GTV and OARs during the course of RT delivery were analyzed. Volumes of GTV and parotid glands were reduced during the course of radiation treatment with an average shrinkage rate of 0.23%/day (range, 0.02 ∼ 0.8%) and 1.2%/day (range, 0.2 ∼ 2.3%), respectively. The mean CTN changes in GTV and ipsi- and contra-lateral parotid glands were reduced by 52±35, 18±20 and 17±22 HUs, respectively. For GTV, the CTN and GTV volume decreases were found to be correlated with each other (p < 0.0001). No noticeable CTN change was found in spinal cord and non-specified tissue irradiated with low doses. The CTN changes in GTV and parotids are measurable during the delivery of fractionated radiotherapy for NPC, were associated with the doses received (the number of fractions delivered), and were patient specific. The CTN change during radiotherapy is dose dependent and is measurable for NPC.


  • Technical Note: Development and performance of a software tool for quality assurance of online replanning with a conventional Linac or MR‐Linac

    by Guang‐Pei Chen, Ergun Ahunbay, X. Allen Li

    Purpose: To develop an integrated quality assurance (QA) software tool for online replanning capable of efficiently and automatically checking radiation treatment (RT) planning parameters and gross plan quality, verifying treatment plan data transfer from treatment planning system (TPS) to record and verify (R&V) system, performing a secondary monitor unit (MU) calculation with or without a presence of a magnetic field from MR‐Linac, and validating the delivery record consistency with the plan.Methods: The software tool, named ArtQA, was developed to obtain and compare plan and treatment parameters from both the TPS and the R&V system database. The TPS data are accessed via direct file reading and the R&V data are retrieved via open database connectivity and structured query language. Plan quality is evaluated with both the logical consistency of planning parameters and the achieved dose–volume histograms. Beams in between the TPS and R&V system are matched based on geometry configurations. To consider the effect of a 1.5 T transverse magnetic field from MR‐Linac in the secondary MU calculation, a method based on modified Clarkson integration algorithm was developed and tested for a series of clinical situations.Results: ArtQA has been used in their clinic and can quickly detect inconsistencies and deviations in the entire RT planning process. With the use of the ArtQA tool, the efficiency for plan check including plan quality, data transfer, and delivery check can be improved by at least 60%. The newly developed independent MU calculation tool for MR‐Linac reduces the difference between the plan and calculated MUs by 10%.Conclusions: The software tool ArtQA can be used to perform a comprehensive QA check from planning to delivery with conventional Linac or MR‐Linac and is an essential tool for online replanning where the QA check needs to be performed rapidly.


  • A planning comparison of 7 irradiation options allowed in RTOG 1005 for early-stage breast cancer

    by Guang-Pei Chen, Feng Liu, Julia White, Frank A. Vicini, Gary M. Freedman, Douglas W. Arthur, X. Allen Li


  • Automated computer optimization for 3D treatment planning of breast irradiation

    by Guang-Pei Chen, Ergun Ahunbay, X. Allen Li

    A software package, capable of optimizing beam energy and weight and wedge angle and orientation in conjunction with commercial treatment planning system, has been developed to effectively generate three-dimensional conformal radiation therapy (3DCRT) plans for breast irradiation with complicated dosimetry requirements. A nonlinear optimization procedure was utilized for the optimization. The study with 15 patient cases shows that the technique can reduce treatment planning time and effort significantly and can give comparable or slightly better dosimetry results. The package can also be used to optimize the beam weights of 3DCRT plans for other treatment sites.


  • A Facile Preparation of an Octahydropyrrolo[2,3-c]pyridine Enantiomer

    by Wen-Chung Shieh, Guang-Pei Chen, Song Xue, Joseph McKenna, Xinglong Jiang, Kapa Prasad, Oljan Repič, Christopher Straub, Sushil K. Sharma