Benedikt Geiger
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Benedikt Geiger has a total of 59 co-authors. Here are the top co-authors by number of shared publications:
- Marianela Garcia-Munoz
University of Seville
2 shared publications - Mirko Salewski
Department of Physics, Technical University of Denmark, Lyngby, Denmark
2 shared publications A N Karpushov
Swiss Plasma Center, EPFL, Lausanne
1 shared publicationAndreas Kraemer-Flecken
IEF-4 (Plasmaphysik), Forschungszentrum Juelich, D-52425 Juelich, Jülich, NRW, 52425, GERMANY
1 shared publication- Andreas Langenberg
Max Planck Institute for Plasma Physics
1 shared publication Asdex Upgrade Team
Max-Planck-Institut für Plasmaphysik, EURATOM Association, Boltzmannstr. 2, 85748 Garching, Germany
1 shared publication
Latest Publications
- 7 February 2019
- Published by IOP Publishing in Nuclear Fusion
- Vol. 59 (4) , 046009
Observation of anomalous impurity transport during low-density experiments in W7-X with laser blow-off injections of iron
- 7 February 2019
- Published by IOP Publishing in Nuclear Fusion
- Vol. 59 (4) , 046009
Observation of anomalous impurity transport during low-density experiments in W7-X with laser blow-off injections of iron
- Open Access
- 17 September 2018
- Published by Springer Nature in Reviews of Modern Plasma Physics
- Vol. 2 (1) , 1-68
Recent progress in fast-ion diagnostics for magnetically confined plasmas
- 17 September 2018
- Published by Springer Nature in Reviews of Modern Plasma Physics
- Vol. 2 (1) , 1-68
Open AccessRecent progress in fast-ion diagnostics for magnetically confined plasmas
- Open Access
- 19 September 2017
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 59 (11) , 115002
Fast-ion transport in low density L-mode plasmas at TCV using FIDA spectroscopy and the TRANSP code
Experiments with the new neutral beam injection source of TCV have been performed with high fast-ion fractions (>20%) that exhibit a clear reduction of the loop voltage and a clear increase of the plasma pressure in on- and off-axis heating configurations. However, good quantitative agreement between the experimental data and TRANSP predictions is only found when including strong additional fast-ion losses. These losses could in part be caused by turbulence or MHD activity as, e.g. high frequency modes near the frequency of toroidicity induced Alfvén eignmodes are observed. In addition, a newly installed fast-ion D-alpha (FIDA) spectroscopy system measures strong passive radiation and, hence, indicates the presence of high background neutral densities such that charge-exchange losses are substantial. Also the active radiation measured with the FIDA diagnostic, as well as data from a neutral particle analyzer, suggest strong fast-ion losses and large neutral densities. The large neutral densities can be justified since high electron temperatures (3–4 keV), combined with low electron densities (about 2 × 10 19 m −3 ) yield long mean free paths of the neutrals which are penetrating from the walls.
- 19 September 2017
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 59 (11) , 115002
Open AccessFast-ion transport in low density L-mode plasmas at TCV using FIDA spectroscopy and the TRANSP code
Experiments with the new neutral beam injection source of TCV have been performed with high fast-ion fractions (>20%) that exhibit a clear reduction of the loop voltage and a clear increase of the plasma pressure in on- and off-axis heating configurations. However, good quantitative agreement between the experimental data and TRANSP predictions is only found when including strong additional fast-ion losses. These losses could in part be caused by turbulence or MHD activity as, e.g. high frequency modes near the frequency of toroidicity induced Alfvén eignmodes are observed. In addition, a newly installed fast-ion D-alpha (FIDA) spectroscopy system measures strong passive radiation and, hence, indicates the presence of high background neutral densities such that charge-exchange losses are substantial. Also the active radiation measured with the FIDA diagnostic, as well as data from a neutral particle analyzer, suggest strong fast-ion losses and large neutral densities. The large neutral densities can be justified since high electron temperatures (3–4 keV), combined with low electron densities (about 2 × 10 19 m −3 ) yield long mean free paths of the neutrals which are penetrating from the walls.
- 1 November 2013
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 84 (11) , 113502
Multi-view fast-ion D-alpha spectroscopy diagnostic at ASDEX Upgrade
A novel fast-ion D-alpha (FIDA) diagnostic that is based on charge exchange spectroscopy has been installed at ASDEX Upgrade. The diagnostic uses a newly developed high-photon-throughput spectrometer together with a low-noise EM-CCD camera that allow measurements with 2 ms exposure time. Absolute intensities are obtained by calibrating the system with an integrating sphere and the wavelength dependence is determined to high accuracy using a neon lamp. Additional perturbative contributions to the spectra, such as -molecular lines, the Stark broadened edge D-alpha emission, and passive FIDA radiation have been identified and can be subtracted or avoided experimentally. The FIDA radiation from fast deuterium ions after charge exchange reactions can therefore be analyzed continuously without superimposed line emissions at large Doppler shifts. Radial information on the fast ions is obtained from radially distributed lines of sight. The investigation of the fast-ion velocity distribution is possible due to three different viewing geometries. The independent viewing geometries access distinct parts of the fast-ion velocity space and make tomographic reconstructions possible.- 1 November 2013
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 84 (11) , 113502
Multi-view fast-ion D-alpha spectroscopy diagnostic at ASDEX Upgrade
A novel fast-ion D-alpha (FIDA) diagnostic that is based on charge exchange spectroscopy has been installed at ASDEX Upgrade. The diagnostic uses a newly developed high-photon-throughput spectrometer together with a low-noise EM-CCD camera that allow measurements with 2 ms exposure time. Absolute intensities are obtained by calibrating the system with an integrating sphere and the wavelength dependence is determined to high accuracy using a neon lamp. Additional perturbative contributions to the spectra, such as -molecular lines, the Stark broadened edge D-alpha emission, and passive FIDA radiation have been identified and can be subtracted or avoided experimentally. The FIDA radiation from fast deuterium ions after charge exchange reactions can therefore be analyzed continuously without superimposed line emissions at large Doppler shifts. Radial information on the fast ions is obtained from radially distributed lines of sight. The investigation of the fast-ion velocity distribution is possible due to three different viewing geometries. The independent viewing geometries access distinct parts of the fast-ion velocity space and make tomographic reconstructions possible.