HSHisakazu Shiroeda

Hisakazu Shiroeda

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hisakazu Shiroeda has a total of 48 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Usefulness of Dual-Phase 18F-FDG PET/CT for Diagnosing Small Pancreatic Tumors

    by Natsuko Kawada, Hiroyuki Uehara, Takuya Hosoki, Motohisa Takami, Hisakazu Shiroeda, Tomiyasu Arisawa, Yasuhiko Tomita

    The usefulness of dual-phase F-fluorodeoxyglucose (F-FDG) positron emission tomography/computed tomography (PET/CT) for pancreatic tumors was investigated including numerous small tumors.Consecutive 116 patients with solid pancreatic tumors were subjected. Maximum standard uptake values (SUVmax) at 1 and 2 hours after FDG injection were defined as early and delayed SUVmax, respectively. Receiver operating characteristic curve was used to determine the optimal cutoff value of early SUVmax. Diagnostic accuracy of dual-phase FDG PET/CT was compared with that of single phase.The mean ± SD tumor size was 25 ±12 mm in diameter. The level of early SUVmax and proportion of elevated SUVmax in delayed phase were significantly higher in malignancy than those in benignancy for less than 25 mm tumors (4.1 ± 2.6 vs 1.9 ± 0.5, P < 0.001; 89% vs 17%, P < 0.0001) although they did not reach statistical significance for greater than or equal to 25 mm tumors. When diagnostic criteria of dual-phase FDG PET/CT for less than 25 mm tumors were determined as (1) early SUVmax greater than or equal to 2.1 and/or (2) delayed SUVmax greater than early SUVmax, sensitivity, specificity, and over all accuracy of dual-phase FDG PET/CT were better than that of single phase for less than 25 mm tumor (93%, 83%, and 91% vs 79%, 83%, and 80%, respectively).Dual-phase FDG PET/CT might be useful for diagnosing small pancreatic tumors.


    • 29 April 2015
      • Vol. 62  (137) , 219-24

    The effect of short-term proton pump inhibitor plus anti-ulcer drug on the healing of endoscopic submucosal dissection-derived artificial ulcer: a randomized controlled trial.

    by Masakatsu Nakamura, Tomomitsu Tahara, Hisakazu Shiroeda, Kazuhiro Matsunaga, Toshimi Otsuka, Joh Yonemura, Tomoyuki Shibata, Tomiyasu Arisawa

    Artificial ulcers remain a major complication after Endoscopic submucosal dissection (ESD). The development of more effective treatment regimen for this ulcer is required than the use of proton pump inhibitor (PPI) alone. Patients with ESD-derived artificial ulcers were randomly assigned to two groups: a group of patients who received rabeprazole 20 mg daily for 8 weeks (PPI group) and a group of patients who received a combination of rebamipide 300 mg daily for 8 weeks and rabeprazole 20 mg dairy for the first 4 weeks (reb+PPI group). The area reduction ratio and healing status of ulcers were evaluated endoscopically on postoperative 7, 28 and 56 days. The overall ulcer area reduction ratio was higher in the reb+PPI group than in the PPI group, especially at an early stage. The ratio of progression to the H1 stage in the reb+PPI group was significantly higher than that in the PPI group, especially at an early stage. Treatment with 8 weeks of rebamipide plus the first 4 weeks of PPI demonstrated a reduction ratio of artificial ulcers superior to that with 8 weeks of PPI mono-therapy. This combination treatment is, therefore, one of the candidate treatment strategies against ESD-derived artificial ulcers.


  • Potential use of point shear wave elastography for the pancreas: A single center prospective study

    by Natsuko Kawada, Sachiko Tanaka, Hiroyuki Uehara, Kazuyoshi Ohkawa, Takuo Yamai, Ryoji Takada, Hisakazu Shiroeda, Tomiyasu Arisawa, Yasuhiko Tomita


  • A new method using a polyglycolic acid monolayer patch to shield the mucosal defect after endoscopic submucosal dissection

    by Masakatsu Nakamura, Hisakazu Shiroeda, Tomomitsu Tahara, Tomoyuki Shibata, Tomiyasu Arisawa

    Recently, an endoscopic shielding method using polyglycolic acid (PGA) sheets (Neoviel, Gunze Co., Kyoto, Japan) and fibrin glue (Bolheal, Kaketsuken, Kumamoto, Japan) has been reported [1] [2]. It is difficult to stretch a PGA sheet out as a monolayer during an endoscopic procedure because the sheets are very thin and their stickiness increases when wet. Therefore, in these previous reports, the mucosal defects have been covered with several strips of PGA [1] [2]. Here, we report a new method that can be used to cover a gastric mucosal defect following endoscopic submucosal dissection (ESD) with just a monolayer of PGA. In the case illustrated, the ESD was performed for an antral gastric cancer ([Fig. 1a, b]). The diameter of the resulting defect was measured ([Fig. 1c]), and the endoscope was pulled out with the resected specimen. A patch that was shaped to fit the area of the defect was then cut from a sheet of PGA and four loops were created close to the edge of the material using absorbable suture thread at the four points of a cross ([Fig. 2 a]). This prepared PGA patch was then picked up by passing one of the loops through the hole of a Zeoclip (Zeon Medical, Tokyo, Japan) that had been passed through the instrument channel of the endoscope ([Fig. 2 b]). The endoscope with the PGA was re-inserted into the stomach and the clip was placed near to the margin of the mucosal defect ([Fig. 3 a]; [Video 1]). The three remaining loops were then also fixed with clips around the margin of the defect ([Fig. 3 b]). Thereafter, the defect was completely covered with the PGA patch by adjusting the air content in the stomach and moving or stretching the PGA using a forceps and the additional clips ([Fig. 3 c]). Once the position was satisfactory, fibrin glue was injected to ensure adhesion of the patch to the defect. We have already used this method in three other cases of gastric cancer ([Fig. 4]). In all these cases, it was possible to completely cover the defect with a monolayer of PGA without any folds being formed. The mean additional time for this procedure was approximately 15 minutes. Endoscopy_UCTN_Code_TTT_1AO_2AC


  • Endoscopic submucosal dissection of an esophageal tumor using a transnasal endoscope without sedation

    by Masakatsu Nakamura, Hisakazu Shiroeda, Tomomitsu Tahara, Tomoyuki Shibata, Tomiyasu Arisawa

    Endoscopic submucosal dissection (ESD) within a narrow lumen is considered difficult. When ESD is conducted transorally for an esophageal tumor, the patient must be under sedation. We have already reported ESD using a transnasal endoscope in the pharynx without sedation [1]. Here, we report the first case of transnasal ESD for esophageal cancer without sedation. The transnasal endoscope we used was the EG-580NW2 (Fujifilm, Tokyo, Japan), newly developed for the treatment of upper gastrointestinal lesions, which has an instrument channel with 2.4 mm inner diameter although its distal end diameter is 5.8 mm ([Fig. 1]). In addition, the EG-580NW2 can be used with a high-frequency electrosurgical system. We performed ESD for esophageal cancer using this endoscope with Nanoshooter, an original attachment hood [1]. The lesion appeared as a brownish area, and irregular vessels were recognized by using the narrow band imaging optical zoom ([Fig. 2]). The endoscope was inserted transnasally without sedation and a 1 : 1 mixture of glycerol and 0.4 % hyaluronic acid [2] was injected into the submucosal layer ([Fig. 3 a]). Once the lesion had been lifted, mucosal resection was performed at the oral end of the lesion ([Fig. 3 b]). Then, a J-turn was made in the gastric lumen, the scope was pulled up to the esophageal lumen, and the mucosa at the anal end of the lesion was fully resected ([Fig. 3 c]). After completely resecting and trimming around the lesion, we used a snare to resect the lesion, to reduce procedure time ([Fig. 4], [Video 1]). The total time taken was approximately 25 minutes. Our method shortened the time required to perform ESD in the esophagus because the anal end of the lesion was easily and completely resected using a J-turn. Moreover, the procedure was conducted without the risk associated with sedation and with little pain for the patient. The new EG-580NW2 transnasal endoscope is a very useful device for ESD. Endoscopy_UCTN_Code_TTT_1AO_2AG


  • Mo1129 Genetic Polymorphism of NFKB1 (rs28362491, -94 ATTG ins/del) Is Associated With Age-Related Gene Methylation in Helicobacter pylori Infected Japanese Subjects

    by Tomiyasu Arisawa, Hisakazu Shiroeda, Tomomitsu Tahara, Masakatsu Nakamura, Tomoe Nomura, Hideto Yamada, Ranji Hayashi, Kazuhiro Matsunaga, Toshimi Otsuka, Nobuyuki Toshikuni, et al.

  • Mo1136 An Association Between Genetic Polymorphisms of Ripk2 (Ile259thr and *351a>G) and the Susceptibility to Gastric Cancer in Japan

    by Tomiyasu Arisawa, Tomomitsu Tahara, Masakatsu Nakamura, Hideto Yamada, Tomoe Nomura, Ranji Hayashi, Kazuhiro Matsunaga, Toshimi Otsuka, Nobuyuki Toshikuni, Hisakazu Shiroeda, et al.

  • Mo1135 The Genetic Polymorphism of Pre-MicroRNA 938, Targeting IL-17A 3'-UTR, Is Associated With the Risk for DAP-kinase Hypermethylation in Helicobacter pylori Infected Japanese Subjects

    by Tomiyasu Arisawa, Hideto Yamada, Tomomitsu Tahara, Masakatsu Nakamura, Tomoe Nomura, Ranji Hayashi, Kazuhiro Matsunaga, Toshimi Otsuka, Nobuyuki Toshikuni, Hisakazu Shiroeda, et al.

  • Mo1131 Genetic Polymorphism of MAFK (Rs4268033) Is Associated With the Susceptibility to Gastric Cancer in Japan

    by Tomiyasu Arisawa, Kazuhiro Matsunaga, Tomomitsu Tahara, Masakatsu Nakamura, Hideto Yamada, Tomoe Nomura, Ranji Hayashi, Toshimi Otsuka, Nobuyuki Toshikuni, Hisakazu Shiroeda, et al.

  • Sa1408 Usefulness of a Nanoshooter As a Tool for ESD of Narrow Organ Lumen With a TransNasal Endoscope

    by Masakatsu Nakamura, Hisakazu Shiroeda, Tomomitsu Tahara, Tomoyuki Shibata, Tomiyasu Arisawa