Peter Bloch
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Peter Bloch has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
James McDonough
3 shared publications- Arnaud Belard
Henry M. Jackson Foundation for the Advancement of Military Medicine, Rockville, MD, USA
1 shared publication Bengt E. Bjärngard
1 shared publicationDickson Goulart
1 shared publicationJames Metz
1 shared publicationJohn Lobdell
1 shared publication
Latest Publications
- 1 June 2006
- Published by Defense Technical Information Center (DTIC)
Development of a Multileaf Collimator for Proton Radiotherapy
This report describes the second year of a project to design and construct multileaf collimators (MLC) to be used in proton radiotherapy, and the first year of the project to develop scanned beam technology for proton radiotherapy. This research project is a joint collaborative effort between the University of Pennsylvania (HUP) and the Walter Reed Army Medical Center (WRAMC) and is part of a larger project to build a state-of-the-art proton radiotherapy facility in Philadelphia in collaboration with the Children s Hospital of Philadelphia (CHOP). The accomplishments during the past year of the project are described in this report. (1) We developed software to read in DICOM-RT datasets and convert them to the GEANT4 geometry structure so we can calculate dose and display DVHs on CT data, (2) We incorporated a realistic proton nozzle into the GEANT4 Monte Carlo, (3) We started the study of spot-scanning optimization and have implemented two algorithms so far, and (4) The WRAMC group has started studying how heterogeneities affect the dose distribution in proton therapy.
- 1 June 2006
- Published by Defense Technical Information Center (DTIC)
Development of a Multileaf Collimator for Proton Radiotherapy
This report describes the second year of a project to design and construct multileaf collimators (MLC) to be used in proton radiotherapy, and the first year of the project to develop scanned beam technology for proton radiotherapy. This research project is a joint collaborative effort between the University of Pennsylvania (HUP) and the Walter Reed Army Medical Center (WRAMC) and is part of a larger project to build a state-of-the-art proton radiotherapy facility in Philadelphia in collaboration with the Children s Hospital of Philadelphia (CHOP). The accomplishments during the past year of the project are described in this report. (1) We developed software to read in DICOM-RT datasets and convert them to the GEANT4 geometry structure so we can calculate dose and display DVHs on CT data, (2) We incorporated a realistic proton nozzle into the GEANT4 Monte Carlo, (3) We started the study of spot-scanning optimization and have implemented two algorithms so far, and (4) The WRAMC group has started studying how heterogeneities affect the dose distribution in proton therapy.
- 1 April 2003
- Published by Elsevier in Cardiovascular Radiation Medicine
- Vol. 4 (2) , 90-94
Dosimetry for an Sr90/Y90 source train used for intravascular radiation of a hemodialysis graft.
- 1 April 2003
- Published by Elsevier in Cardiovascular Radiation Medicine
- Vol. 4 (2) , 90-94
Dosimetry for an Sr90/Y90 source train used for intravascular radiation of a hemodialysis graft.
- 12 February 1999
- Published by Wiley in Medical Physics
- Vol. 26 (2) , 200-205
Determination of scatter factor parameters and electron disequilibrium for monoenergetic photon beams
The tissue-phantom-ratio (TPR) is expressed as the product of the phantom scatter factor (SF), an electron disequilibrium factor, and an attenuation factor, equal to the zero-area TPR. The scatter factor, as a function of depth d and field size s, has been described by two parameters a and w, SF(d,s) = 1 + asd/(ws + d). We have determined the parameters a and w for 20 monoenergetic photon beams between 1 and 20 MeV. Pencil-beam energy-deposition kernels were obtained using Monte Carlo simulations. The kernels were used to calculate broad-beam depth-dose data, which were converted to TPR and fitted to the equation above using an iterative search over a-w space. The parameter a is nearly equal to the attenuation coefficient for all energies while the parameter w increases with energy. The resulting a and w compare favorably to values determined for clinical photon beams, as a function of the measured attenuation coefficient. With the scatter factor determined, we isolated the electron disequilibrium factor for each monoenergetic beam. It can be characterized as a quadratic function of the depth. The coefficients of the quadratic function can be related to the range of the most energetic secondary electron produced.
- 12 February 1999
- Published by Wiley in Medical Physics
- Vol. 26 (2) , 200-205
Determination of scatter factor parameters and electron disequilibrium for monoenergetic photon beams
The tissue-phantom-ratio (TPR) is expressed as the product of the phantom scatter factor (SF), an electron disequilibrium factor, and an attenuation factor, equal to the zero-area TPR. The scatter factor, as a function of depth d and field size s, has been described by two parameters a and w, SF(d,s) = 1 + asd/(ws + d). We have determined the parameters a and w for 20 monoenergetic photon beams between 1 and 20 MeV. Pencil-beam energy-deposition kernels were obtained using Monte Carlo simulations. The kernels were used to calculate broad-beam depth-dose data, which were converted to TPR and fitted to the equation above using an iterative search over a-w space. The parameter a is nearly equal to the attenuation coefficient for all energies while the parameter w increases with energy. The resulting a and w compare favorably to values determined for clinical photon beams, as a function of the measured attenuation coefficient. With the scatter factor determined, we isolated the electron disequilibrium factor for each monoenergetic beam. It can be characterized as a quadratic function of the depth. The coefficients of the quadratic function can be related to the range of the most energetic secondary electron produced.
- 1 May 1998
- Published by Wiley in Medical Physics
- Vol. 25 (5) , 752-757
Extraction of the photon spectra from measured beam parameters
Knowledge of the photon spectrum of a radiotherapy beam is often needed for three-dimensional (3-D) dose calculations using Monte Carlo methods and/or algorithms employing energy deposition kernels. Direct measurement of the x-ray energy fluence spectrum is not feasible for the high-energy photon beams used clinically. In this paper, the spectrum is extracted from basic beam data that are readily obtained for a clinical beam. We describe the photon spectrum using just two parameters. One parameter, which determines the high-energy part of the spectrum, is obtained using the measured dose in the buildup region for a small field, where electron contamination of the beam can be neglected. The other parameter is extracted from the photon beam attenuation in water. The results compare favorably to spectra generated from Monte Carlo simulations.
- 1 May 1998
- Published by Wiley in Medical Physics
- Vol. 25 (5) , 752-757
Extraction of the photon spectra from measured beam parameters
Knowledge of the photon spectrum of a radiotherapy beam is often needed for three-dimensional (3-D) dose calculations using Monte Carlo methods and/or algorithms employing energy deposition kernels. Direct measurement of the x-ray energy fluence spectrum is not feasible for the high-energy photon beams used clinically. In this paper, the spectrum is extracted from basic beam data that are readily obtained for a clinical beam. We describe the photon spectrum using just two parameters. One parameter, which determines the high-energy part of the spectrum, is obtained using the measured dose in the buildup region for a small field, where electron contamination of the beam can be neglected. The other parameter is extracted from the photon beam attenuation in water. The results compare favorably to spectra generated from Monte Carlo simulations.