- 3 December 1998
- Published by Wiley in Medical Physics
- Vol. 25 (12) , 2455-2462
Characteristics of metal‐plate/film detectors at therapy energies. I. Modulation transfer function
Measurements of modulation transfer function (MTF) for front and back metal‐plate/film portal detectors are reported for the Cobalt‐60 and 10 MV spectra. The detectors consist of a double‐emulsion portal film secured between plates of Al, Cu, brass, or Pb with thicknesses varying from 0 to 4.81 mm. Secondary electrons produced within the front plate generate the main signal, but the MTF decreases with an increase in front plate thickness greater than the maximum range of electrons because of photon scatter in the front plate. Because the decrease of MTF with backplate thickness ceases for backplate thickness greater than the MTF is influenced more by the backscatter electrons than the backscatter photons.
- 3 December 1998
- Published by Wiley in Medical Physics
- Vol. 25 (12) , 2455-2462
Characteristics of metal‐plate/film detectors at therapy energies. I. Modulation transfer function
Measurements of modulation transfer function (MTF) for front and back metal‐plate/film portal detectors are reported for the Cobalt‐60 and 10 MV spectra. The detectors consist of a double‐emulsion portal film secured between plates of Al, Cu, brass, or Pb with thicknesses varying from 0 to 4.81 mm. Secondary electrons produced within the front plate generate the main signal, but the MTF decreases with an increase in front plate thickness greater than the maximum range of electrons because of photon scatter in the front plate. Because the decrease of MTF with backplate thickness ceases for backplate thickness greater than the MTF is influenced more by the backscatter electrons than the backscatter photons.
- 3 December 1998
- Published by Wiley in Medical Physics
- Vol. 25 (12) , 2463-2468
Characteristics of metal‐plate/film detectors at therapy energies. II. Detective quantum efficiency
Noise power spectrum (NPS) and detective quantum efficiency (DQE) for metal‐plate/film portal detectors are reported for the Co‐60 and Linac 10 MV spectra. The detectors consist of a double‐emulsion portal film secured between plates of aluminum, copper, brass, or lead. The NPS was found to be independent of the detector sensitivity demonstrating that the film grain noise dominates over the quantum noise. Although the detector signal increases with density of the backplates, the resultant electron‐backscatter increases detector blur, thus decreasing the DQE. The lowest DQEs are therefore produced with the lead backplates, irrespective of the front plates. For a given backplate and for front‐plate thicknesses less than the maximum electron range, the DQE increases with density of the front plate.
- 3 December 1998
- Published by Wiley in Medical Physics
- Vol. 25 (12) , 2463-2468
Characteristics of metal‐plate/film detectors at therapy energies. II. Detective quantum efficiency
Noise power spectrum (NPS) and detective quantum efficiency (DQE) for metal‐plate/film portal detectors are reported for the Co‐60 and Linac 10 MV spectra. The detectors consist of a double‐emulsion portal film secured between plates of aluminum, copper, brass, or lead. The NPS was found to be independent of the detector sensitivity demonstrating that the film grain noise dominates over the quantum noise. Although the detector signal increases with density of the backplates, the resultant electron‐backscatter increases detector blur, thus decreasing the DQE. The lowest DQEs are therefore produced with the lead backplates, irrespective of the front plates. For a given backplate and for front‐plate thicknesses less than the maximum electron range, the DQE increases with density of the front plate.