Jack L.M. Venselaar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jack L.M. Venselaar has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
B J Mijnheer
2 shared publicationsC F Westermann
2 shared publicationsH J van Kleffens
2 shared publicationsH N Jager
2 shared publicationsJ J M van Gasteren
2 shared publicationsR van der Laarse
2 shared publications
Latest Publications
- Open Access
- 8 July 2013
- Published by Springer Nature in Radiation Oncology
- Vol. 8 (1) , 172
Second primary cancers after radiation for prostate cancer: a review of data from planning studies
A review of planning studies was undertaken to evaluate estimated risks of radiation induced second primary cancers (RISPC) associated with different prostate radiotherapy techniques for localised prostate cancer. A total of 83 publications were identified which employed a variety of methods to estimate RISPC risk. Of these, the 16 planning studies which specifically addressed absolute or relative second cancer risk using dose–response models were selected for inclusion within this review. There are uncertainties and limitations related to all the different methods for estimating RISPC risk. Whether or not dose models include the effects of the primary radiation beam, as well as out-of-field regions, influences estimated risks. Regarding the impact of IMRT compared to 3D-CRT, at equivalent energies, several studies suggest an increase in risk related to increased leakage contributing to out-of-field RISPC risk, although in absolute terms this increase in risk may be very small. IMRT also results in increased low dose normal tissue irradiation, but the extent to which this has been estimated to contribute to RISPC risk is variable, and may also be very small. IMRT is often delivered using 6MV photons while conventional radiotherapy often requires higher energies to achieve adequate tissue penetration, and so comparisons between IMRT and older techniques should not be restricted to equivalent energies. Proton and brachytherapy planning studies suggest very low RISPC risks associated with these techniques. Until there is sufficient clinical evidence regarding RISPC risks associated with modern irradiation techniques, the data produced from planning studies is relevant when considering which patients to irradiate, and which technique to employ.
- 8 July 2013
- Published by Springer Nature in Radiation Oncology
- Vol. 8 (1) , 172
Open AccessSecond primary cancers after radiation for prostate cancer: a review of data from planning studies
A review of planning studies was undertaken to evaluate estimated risks of radiation induced second primary cancers (RISPC) associated with different prostate radiotherapy techniques for localised prostate cancer. A total of 83 publications were identified which employed a variety of methods to estimate RISPC risk. Of these, the 16 planning studies which specifically addressed absolute or relative second cancer risk using dose–response models were selected for inclusion within this review. There are uncertainties and limitations related to all the different methods for estimating RISPC risk. Whether or not dose models include the effects of the primary radiation beam, as well as out-of-field regions, influences estimated risks. Regarding the impact of IMRT compared to 3D-CRT, at equivalent energies, several studies suggest an increase in risk related to increased leakage contributing to out-of-field RISPC risk, although in absolute terms this increase in risk may be very small. IMRT also results in increased low dose normal tissue irradiation, but the extent to which this has been estimated to contribute to RISPC risk is variable, and may also be very small. IMRT is often delivered using 6MV photons while conventional radiotherapy often requires higher energies to achieve adequate tissue penetration, and so comparisons between IMRT and older techniques should not be restricted to equivalent energies. Proton and brachytherapy planning studies suggest very low RISPC risks associated with these techniques. Until there is sufficient clinical evidence regarding RISPC risks associated with modern irradiation techniques, the data produced from planning studies is relevant when considering which patients to irradiate, and which technique to employ.
- Open Access
- 1 January 2010
- Published by Termedia Sp. z.o.o. in Journal of Contemporary Brachytherapy
- Vol. 4 (4) , 145-152
Clinical Investigations Original article Patterns of care study for brachytherapy: results of the questionnaire for the years 2002 and 2007 in The Netherlands
Purpose : The goal of the ESTRO Patterns of Care study for Brachytherapy in Europe (PCBE) 2002 was to develop an aid to analyse brachytherapy practices. A 2nd version of the PCB questionnaire was created for 2007. Data over 2007 were collected at the radiotherapy institutions in The Netherlands...
- 1 January 2010
- Published by Termedia Sp. z.o.o. in Journal of Contemporary Brachytherapy
- Vol. 4 (4) , 145-152
Open AccessClinical Investigations Original article Patterns of care study for brachytherapy: results of the questionnaire for the years 2002 and 2007 in The Netherlands
Purpose : The goal of the ESTRO Patterns of Care study for Brachytherapy in Europe (PCBE) 2002 was to develop an aid to analyse brachytherapy practices. A 2nd version of the PCB questionnaire was created for 2007. Data over 2007 were collected at the radiotherapy institutions in The Netherlands...
- 1 December 2001
- Published by Elsevier in Medical Dosimetry
- Vol. 26 (4) , 309-314
Verification of dose calculations with a treatment planning system for open and wedged fields of a 60Co unit with a new asymmetric collimator
- 1 December 2001
- Published by Elsevier in Medical Dosimetry
- Vol. 26 (4) , 309-314
Verification of dose calculations with a treatment planning system for open and wedged fields of a 60Co unit with a new asymmetric collimator
- 1 October 1999
- Published by Wiley in Medical Physics
- Vol. 26 (10) , 2099-2106
Effect of electron contamination on scatter correction factors for photon beam dosimetry
Physical quantities for use in megavoltage photon beam dose calculations which are defined at the depth of maximum absorbed dose are sensitive to electron contamination and are difficult to measure and to calculate. Recently, formalisms have therefore been presented to assess the dose using collimator and phantom scatter correction factors, Sc and Sp, defined at a reference depth of 10 cm. The data can be obtained from measurements at that depth in a miniphantom and in a full scatter phantom. Equations are presented that show the relation between these quantities and corresponding quantities obtained from measurements at the depth of the dose maximum. It is shown that conversion of Sc and Sp determined at a 10 cm depth to quantities defined at the dose maximum such as (normalized) peak scatter factor, (normalized) tissue-air ratio, and vice versa is not possible without quantitative knowledge of the electron contamination. The difference in Sc at dmax resulting from this electron contamination compared with Sc values obtained at a depth of 10 cm in a miniphantom has been determined as a multiplication factor, Scel, for a number of photon beams of different accelerator types. It is shown that Scel may vary up to 5%. Because in the new formalisms output factors are defined at a reference depth of 10 cm, they do not require Scel data. The use of Sc and Sp values, defined at a 10 cm depth, combined with relative depth-dose data or tissue-phantom ratios is therefore recommended. For a transition period the use of the equations provided in this article and Scel data might be required, for instance, if treatment planning systems apply Sc data normalized at d(max).
- 1 October 1999
- Published by Wiley in Medical Physics
- Vol. 26 (10) , 2099-2106
Effect of electron contamination on scatter correction factors for photon beam dosimetry
Physical quantities for use in megavoltage photon beam dose calculations which are defined at the depth of maximum absorbed dose are sensitive to electron contamination and are difficult to measure and to calculate. Recently, formalisms have therefore been presented to assess the dose using collimator and phantom scatter correction factors, Sc and Sp, defined at a reference depth of 10 cm. The data can be obtained from measurements at that depth in a miniphantom and in a full scatter phantom. Equations are presented that show the relation between these quantities and corresponding quantities obtained from measurements at the depth of the dose maximum. It is shown that conversion of Sc and Sp determined at a 10 cm depth to quantities defined at the dose maximum such as (normalized) peak scatter factor, (normalized) tissue-air ratio, and vice versa is not possible without quantitative knowledge of the electron contamination. The difference in Sc at dmax resulting from this electron contamination compared with Sc values obtained at a depth of 10 cm in a miniphantom has been determined as a multiplication factor, Scel, for a number of photon beams of different accelerator types. It is shown that Scel may vary up to 5%. Because in the new formalisms output factors are defined at a reference depth of 10 cm, they do not require Scel data. The use of Sc and Sp values, defined at a 10 cm depth, combined with relative depth-dose data or tissue-phantom ratios is therefore recommended. For a transition period the use of the equations provided in this article and Scel data might be required, for instance, if treatment planning systems apply Sc data normalized at d(max).
- 1 January 1999
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 44 (2) , 365-381
A consistent formalism for the application of phantom and collimator scatter factors
A coherent system for the use of scatter correction factors, determined at 10 cm depth, is described for dose calculations on the central axis of arbitrarily shaped photon beams. The system is suitable for application in both the fixed source-surface distance (SSD) and in the isocentric treatment set-up. This is in contrast to some other proposals where only one of these approaches forms the basis of the calculation system or where distinct quantities and data sets are needed. In order to derive the relations in the formalism, we introduced a separation of the phenomena related to the energy fluence in air and to the phantom scatter contribution to the dose. Both are used relative to quantities defined for the reference irradiation set-up. It is shown that dose calculations can be performed with only one set of basic beam data, obtained at a reference depth of 10 cm. These data consist for each photon beam quality of measured collimator and phantom scatter correction factors, in combination with a set of (percentage/relative) depth-dose or tissue-phantom ratio values measured along the central axis of the beam. Problems related to measurements performed at the depth of maximum absorbed dose, due to the electron contamination of the beam, are avoided in this way. Collimator scatter correction factors are obtained by using a mini-phantom, while phantom scatter correction factors are derived from measurements in a full scatter phantom in combination with the results of the mini-phantom measurements. For practical reasons the fixed SSD system was chosen to determine the data. Then, dose calculations in a fixed SSD treatment set-up itself are straightforward. Application in the isocentric treatment set-up needs simple conversion steps, while the inverse approach, from isocentric to fixed SSD, is described as well. Differences between the two approaches are discussed and the equations for the conversions are given.
- 1 January 1999
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 44 (2) , 365-381
A consistent formalism for the application of phantom and collimator scatter factors
A coherent system for the use of scatter correction factors, determined at 10 cm depth, is described for dose calculations on the central axis of arbitrarily shaped photon beams. The system is suitable for application in both the fixed source-surface distance (SSD) and in the isocentric treatment set-up. This is in contrast to some other proposals where only one of these approaches forms the basis of the calculation system or where distinct quantities and data sets are needed. In order to derive the relations in the formalism, we introduced a separation of the phenomena related to the energy fluence in air and to the phantom scatter contribution to the dose. Both are used relative to quantities defined for the reference irradiation set-up. It is shown that dose calculations can be performed with only one set of basic beam data, obtained at a reference depth of 10 cm. These data consist for each photon beam quality of measured collimator and phantom scatter correction factors, in combination with a set of (percentage/relative) depth-dose or tissue-phantom ratio values measured along the central axis of the beam. Problems related to measurements performed at the depth of maximum absorbed dose, due to the electron contamination of the beam, are avoided in this way. Collimator scatter correction factors are obtained by using a mini-phantom, while phantom scatter correction factors are derived from measurements in a full scatter phantom in combination with the results of the mini-phantom measurements. For practical reasons the fixed SSD system was chosen to determine the data. Then, dose calculations in a fixed SSD treatment set-up itself are straightforward. Application in the isocentric treatment set-up needs simple conversion steps, while the inverse approach, from isocentric to fixed SSD, is described as well. Differences between the two approaches are discussed and the equations for the conversions are given.
- 1 January 1998
- Published by Elsevier in Medical Dosimetry
- Vol. 23 (2) , 99-103
A Solution for the Treatment of Small Lesions Using Electron Beams From a Saturne Linear Accelerator With Continuous Variable Trimmers; Dosimetrical Aspects
- 1 January 1998
- Published by Elsevier in Medical Dosimetry
- Vol. 23 (2) , 99-103
A Solution for the Treatment of Small Lesions Using Electron Beams From a Saturne Linear Accelerator With Continuous Variable Trimmers; Dosimetrical Aspects
- 1 December 1997
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 42 (12) , 2369-2381
Is there a need for a revised table of equivalent square fields for the determination of phantom scatter correction factors?
The use of the British Journal of Radiology (BJR) (supplement 17) tables of equivalent square fields for dose calculations is widespread. A revised version of the supplement was published recently, with a more elaborate discussion, but without changes in data given in these tables ( Br. J. Radiol. suppl 25). The tables were generated for use in dose calculations, with relative beam data such as PDD, BSF, PSF, all with as the reference depth. However, the current philosophy in dose calculational methods is based on quantities defined at a reference depth, , on a separation of phantom and head scatter, and on the use of the relative depth - dose or tissue - phantom ratios normalized at . By using these quantities as a starting point, problems at shallow depths related to the influence of contaminating electrons in the beam can be eliminated. Recently, a comprehensive set of phantom scatter factor data with has been published for a set of square field sizes and a wide range of photon beam energies, showing that phantom scatter is a smoothly varying function of field size and quality index. It is not a priori evident that the conventional concept of equivalent squares for rectangular fields is also fully applicable for phantom scatter factors and phantom scatter related quantities at a depth of 10 cm. It was questioned whether or not new tables of equivalent square fields are needed for this purpose. In this paper, new tables have been constructed for four photon beam energies in the range of Co-60 to 25 MV (quality index from 0.572 to 0.783). The small differences between the outcome of these new tables allowed the construction of one averaged table of equivalent square fields. Phantom scatter factors were calculated for rectangular fields based on the use of the BJR table and on the use of the newly constructed tables and the differences were quantified. For Co-60 no improvements could be shown when using the new averaged table, but for beam energies of 6 to 10 MV small improvements of the order of 0.5 to 1.0% were found. For a higher beam energy of 25 MV the improvement is smaller. Deviations resulting from the BJR table are within the limits of accuracy as stated by the authors. Therefore, for clinical use, the continued use of the BJR table of equivalent squares for phantom scatter factors and phantom scatter related quantities of rectangular fields is justified, irrespective of photon beam energy.
- 1 December 1997
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 42 (12) , 2369-2381
Is there a need for a revised table of equivalent square fields for the determination of phantom scatter correction factors?
The use of the British Journal of Radiology (BJR) (supplement 17) tables of equivalent square fields for dose calculations is widespread. A revised version of the supplement was published recently, with a more elaborate discussion, but without changes in data given in these tables ( Br. J. Radiol. suppl 25). The tables were generated for use in dose calculations, with relative beam data such as PDD, BSF, PSF, all with as the reference depth. However, the current philosophy in dose calculational methods is based on quantities defined at a reference depth, , on a separation of phantom and head scatter, and on the use of the relative depth - dose or tissue - phantom ratios normalized at . By using these quantities as a starting point, problems at shallow depths related to the influence of contaminating electrons in the beam can be eliminated. Recently, a comprehensive set of phantom scatter factor data with has been published for a set of square field sizes and a wide range of photon beam energies, showing that phantom scatter is a smoothly varying function of field size and quality index. It is not a priori evident that the conventional concept of equivalent squares for rectangular fields is also fully applicable for phantom scatter factors and phantom scatter related quantities at a depth of 10 cm. It was questioned whether or not new tables of equivalent square fields are needed for this purpose. In this paper, new tables have been constructed for four photon beam energies in the range of Co-60 to 25 MV (quality index from 0.572 to 0.783). The small differences between the outcome of these new tables allowed the construction of one averaged table of equivalent square fields. Phantom scatter factors were calculated for rectangular fields based on the use of the BJR table and on the use of the newly constructed tables and the differences were quantified. For Co-60 no improvements could be shown when using the new averaged table, but for beam energies of 6 to 10 MV small improvements of the order of 0.5 to 1.0% were found. For a higher beam energy of 25 MV the improvement is smaller. Deviations resulting from the BJR table are within the limits of accuracy as stated by the authors. Therefore, for clinical use, the continued use of the BJR table of equivalent squares for phantom scatter factors and phantom scatter related quantities of rectangular fields is justified, irrespective of photon beam energy.
- 1 September 1995
- Published by Wiley in Medical Physics
- Vol. 22 (9) , 1473
Comment on “Intercomparison of normalized head-scatter factor measurement techniques” [Med. Phys. 22 , 249-253 (1995)]
- 1 September 1995
- Published by Wiley in Medical Physics
- Vol. 22 (9) , 1473
Comment on “Intercomparison of normalized head-scatter factor measurement techniques” [Med. Phys. 22 , 249-253 (1995)]