Weiliang Du
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Weiliang Du has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Marta A. Zamora
Department of Radiology, University of Chicago, Chicago, Illinois
3 shared publications- Xiaobing Fan
Department of Radiology, University of Chicago, Chicago, IL 60637, USA
3 shared publications - Gregory S. Karczmar
Department of Radiology, University of Chicago, Chicago, Illinois
2 shared publications - Milica Medved
Department of Radiology, University of Chicago, Chicago, IL 60637, USA
2 shared publications - Olufunmilayo Olopade
The University of Chicago
2 shared publications Peter M. MacEneaney
Department of Radiology, University of Chicago, Chicago, Illinois
2 shared publications
Latest Publications
- Open Access
- 28 June 2004
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 52 (1) , 193-196
Fourier components of inhomogeneously broadened water resonances in breast: A new source of MRI contrast
High spectral and spatial resolution (HiSS) MR data were acquired at 1.5 T using echo-planar spectroscopic imaging from patients with suspicious breast lesions. The water resonances in small voxels are inhomogenously broadened and often have distinct components. Images were calculated with intensity proportional to the Fourier components of the water resonance in each voxel at different offsets from the peak frequency. The results demonstrate that in breast the off-peak Fourier component images of water are qualitatively different from those derived from the peak height of the water resonance. These differences most likely reflect underlying anatomy or physiology. In conventional images, the superposition of the various Fourier components of the water signal may cause loss of detail. The synthesis of water Fourier component images from high spectral and spatial resolution data may provide a new form of contrast, and increase sensitivity to subvoxel physiology and anatomy. Magn Reson Med 52:193–196, 2004.
- 28 June 2004
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 52 (1) , 193-196
Open AccessFourier components of inhomogeneously broadened water resonances in breast: A new source of MRI contrast
High spectral and spatial resolution (HiSS) MR data were acquired at 1.5 T using echo-planar spectroscopic imaging from patients with suspicious breast lesions. The water resonances in small voxels are inhomogenously broadened and often have distinct components. Images were calculated with intensity proportional to the Fourier components of the water resonance in each voxel at different offsets from the peak frequency. The results demonstrate that in breast the off-peak Fourier component images of water are qualitatively different from those derived from the peak height of the water resonance. These differences most likely reflect underlying anatomy or physiology. In conventional images, the superposition of the various Fourier components of the water signal may cause loss of detail. The synthesis of water Fourier component images from high spectral and spatial resolution data may provide a new form of contrast, and increase sensitivity to subvoxel physiology and anatomy. Magn Reson Med 52:193–196, 2004.
- Open Access
- 19 September 2003
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 18 (4) , 442-448
The effect of varying spectral resolution on the quality of high spectral and spatial resolution magnetic resonance images of the breast
- 19 September 2003
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 18 (4) , 442-448
Open AccessThe effect of varying spectral resolution on the quality of high spectral and spatial resolution magnetic resonance images of the breast
- Open Access
- 16 May 2003
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 49 (6) , 1113-1120
Reduction of spectral ghost artifacts in high‐resolution echo‐planar spectroscopic imaging of water and fat resonances
Echo-planar spectroscopic imaging (EPSI) can be used for fast spectroscopic imaging of water and fat resonances at high resolution to improve structural and functional imaging. Because of the use of oscillating gradients during the free induction decay (FID), spectra obtained with EPSI are often degraded by Nyquist ghost artifacts arising from the inconsistency between the odd and even echoes. The presence of the spectral ghost lines causes errors in the evaluation of the true spectral lines, and this degrades images derived from high-resolution EPSI data. A technique is described for reducing the spectral ghost artifacts in EPSI of water and fat resonances, using echo shift and zero-order phase corrections. These corrections are applied during the data postprocessing. This technique is demonstrated with EPSI data acquired from human brains and breasts at 1.5 Tesla and from a water phantom at 4.7 Tesla. Experimental results indicate that the present approach significantly reduces the intensities of spectral ghosts. This technique is most useful in conjunction with high-resolution EPSI of water and fat resonances, but is less applicable to EPSI of metabolites due to the complexity of the spectra. Magn Reson Med 49:1113–1120, 2003.
- 16 May 2003
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 49 (6) , 1113-1120
Open AccessReduction of spectral ghost artifacts in high‐resolution echo‐planar spectroscopic imaging of water and fat resonances
Echo-planar spectroscopic imaging (EPSI) can be used for fast spectroscopic imaging of water and fat resonances at high resolution to improve structural and functional imaging. Because of the use of oscillating gradients during the free induction decay (FID), spectra obtained with EPSI are often degraded by Nyquist ghost artifacts arising from the inconsistency between the odd and even echoes. The presence of the spectral ghost lines causes errors in the evaluation of the true spectral lines, and this degrades images derived from high-resolution EPSI data. A technique is described for reducing the spectral ghost artifacts in EPSI of water and fat resonances, using echo shift and zero-order phase corrections. These corrections are applied during the data postprocessing. This technique is demonstrated with EPSI data acquired from human brains and breasts at 1.5 Tesla and from a water phantom at 4.7 Tesla. Experimental results indicate that the present approach significantly reduces the intensities of spectral ghosts. This technique is most useful in conjunction with high-resolution EPSI of water and fat resonances, but is less applicable to EPSI of metabolites due to the complexity of the spectra. Magn Reson Med 49:1113–1120, 2003.
- 24 July 2002
- Published by Wiley in Medical Physics
- Vol. 29 (8) , 1832-1838
Effects of constant frequency noise in magnetic resonance imaging with nonuniformk‐space sampling
Magnetic resonance images can be compromised by constant frequency (CF) noise, such as radio frequency (RF) noise. We investigate the effects of CF noise in four imaging methods with non-uniform k-space sampling: single-shot echo-planar imaging (EPI) with sinusoidal readout gradients, phase-encoded echo-planar spectroscopic imaging (EPSI) with sinusoidal readout gradients, projection-reconstruction imaging, and single-shot spiral imaging. The characteristics of the CF artifacts in each imaging method are studied with numerical simulations. CF noise is found to cause artifacts of nonclassic forms in the reconstructed images. Specifically, dashed-line, streak, and spiral patterns of CF noise appear in EPI/EPSI with sinusoidal readout gradients, projection-reconstruction imaging, and spiral imaging, respectively. The analytical expression for dashed-line artifacts is found to be a weighted sum of Bessel functions and is verified with in vivo experiments. The CF artifacts can be removed during post-processing by eliminating the noise spikes in the Fourier domain of the raw data.
- 24 July 2002
- Published by Wiley in Medical Physics
- Vol. 29 (8) , 1832-1838
Effects of constant frequency noise in magnetic resonance imaging with nonuniformk‐space sampling
Magnetic resonance images can be compromised by constant frequency (CF) noise, such as radio frequency (RF) noise. We investigate the effects of CF noise in four imaging methods with non-uniform k-space sampling: single-shot echo-planar imaging (EPI) with sinusoidal readout gradients, phase-encoded echo-planar spectroscopic imaging (EPSI) with sinusoidal readout gradients, projection-reconstruction imaging, and single-shot spiral imaging. The characteristics of the CF artifacts in each imaging method are studied with numerical simulations. CF noise is found to cause artifacts of nonclassic forms in the reconstructed images. Specifically, dashed-line, streak, and spiral patterns of CF noise appear in EPI/EPSI with sinusoidal readout gradients, projection-reconstruction imaging, and spiral imaging, respectively. The analytical expression for dashed-line artifacts is found to be a weighted sum of Bessel functions and is verified with in vivo experiments. The CF artifacts can be removed during post-processing by eliminating the noise spikes in the Fourier domain of the raw data.