Mijail Demian Serruya
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mijail Demian Serruya has a total of 138 co-authors. Here are the top co-authors by number of shared publications:
Alessandro Napoli
Jefferson Health
7 shared publications- Alessandro Napoli
Raphael Center for Neurorestoration, Thomas Jefferson University Hospital, Philadelphia, PA 19107, USA
5 shared publications Ashwini Sharan
Department of neurosurgery, Thomas Jefferson University, Philadelphia, USA
4 shared publications- Giuliana Vallecorsa
Department of Psychology and Neuroscience, Temple University, Weiss Hall1701 N 13th St, Philadelphia, US
4 shared publications - Katherine Hackett
Department of Psychology and Neuroscience, Temple University, Weiss Hall1701 N 13th St, Philadelphia, US
4 shared publications - Marina Kaplan
Department of Psychology and Neuroscience, Temple University
4 shared publications
Latest Publications
- Open Access
- 21 October 2026
- Published by Frontiers Media SA in Frontiers in Human Neuroscience
- Vol. 20, 1893045
From a surgeon's stroke to a third hemisphere—The auxilium architecture for brain restoration and extension
A surgeon was exercising on a stationary bicycle when he had a large ischemic left middle cerebral artery territory stroke, complicated by hemorrhagic transformation requiring hemicraniectomy and cranioplasty. He developed right-sided spastic hemiplegia and a mixed aphasia. This paper takes that case as its anchor to pose the question: beyond improving residual function, what would it mean to restore cognitive function that was lost so that the person fully returns to their pre-stroke baseline? Existing brain-computer interfaces rely on the person having an intact cortical substrate for intended movement and speech. Here we propose the Auxilium, a brain restoration architecture for the situation where that substrate is no longer present: an extracranial auxiliary brain system, agnostic to its substrate, that connects to a person's residual cortex through whatever input-output technology proves most appropriate, and that supplies, in parallel and in real time, new substrate, whether biological or synthetic. We address an assumption of brain-computer interface development, that throughput is the binding constraint. Linking a kHz brain to MHz digital does not impart the higher clock speed, because the limitation lies not in the port but in the architecture of the entire brain and body imparted by evolution. We posit that the substrate of canonical circuits and their integration areas is essential, and the Auxilium can be understood as restoring both connectivity (linkage between disconnected areas) and computation (information generation capability of a volume of neural tissue). We propose a near-term de-risking pipeline using stereoelectroencephalography during surgical epilepsy evaluation, comparing extracranial modules spanning threshold rules, PID controllers, expert systems, artificial neural networks, neuromorphic devices, and biological specimens, each linked in real time to a participant serving as their own control on naturalistic tasks. If ports alone restore the lost function, the requirement is routing connectivity. If performance improves only when the module supplies its own dynamics, the requirement is computational substrate. We expect the answer to depend on how much tissue was lost, how quickly, and on the individual's reserve, and we treat routing and substrate as endpoints of a continuum to be mapped empirically.
- 21 October 2026
- Published by Frontiers Media SA in Frontiers in Human Neuroscience
- Vol. 20, 1893045
Open AccessFrom a surgeon's stroke to a third hemisphere—The auxilium architecture for brain restoration and extension
A surgeon was exercising on a stationary bicycle when he had a large ischemic left middle cerebral artery territory stroke, complicated by hemorrhagic transformation requiring hemicraniectomy and cranioplasty. He developed right-sided spastic hemiplegia and a mixed aphasia. This paper takes that case as its anchor to pose the question: beyond improving residual function, what would it mean to restore cognitive function that was lost so that the person fully returns to their pre-stroke baseline? Existing brain-computer interfaces rely on the person having an intact cortical substrate for intended movement and speech. Here we propose the Auxilium, a brain restoration architecture for the situation where that substrate is no longer present: an extracranial auxiliary brain system, agnostic to its substrate, that connects to a person's residual cortex through whatever input-output technology proves most appropriate, and that supplies, in parallel and in real time, new substrate, whether biological or synthetic. We address an assumption of brain-computer interface development, that throughput is the binding constraint. Linking a kHz brain to MHz digital does not impart the higher clock speed, because the limitation lies not in the port but in the architecture of the entire brain and body imparted by evolution. We posit that the substrate of canonical circuits and their integration areas is essential, and the Auxilium can be understood as restoring both connectivity (linkage between disconnected areas) and computation (information generation capability of a volume of neural tissue). We propose a near-term de-risking pipeline using stereoelectroencephalography during surgical epilepsy evaluation, comparing extracranial modules spanning threshold rules, PID controllers, expert systems, artificial neural networks, neuromorphic devices, and biological specimens, each linked in real time to a participant serving as their own control on naturalistic tasks. If ports alone restore the lost function, the requirement is routing connectivity. If performance improves only when the module supplies its own dynamics, the requirement is computational substrate. We expect the answer to depend on how much tissue was lost, how quickly, and on the individual's reserve, and we treat routing and substrate as endpoints of a continuum to be mapped empirically.
- Open Access
A Pilot Study of the Feasibility of In-Ear EEG for Long-Term Temporal Lobe Brain Wave Monitoring
Background: Traditional scalp electroencephalography (EEG), though clinically validated, presents significant limitations, including lengthy setup, patient discomfort, and limited mobility. These factors hinder its utility for long-term ambulatory monitoring. In-ear EEG offers a promising alternative by leveraging the ear canal’s anatomical proximity to the temporal lobes and natural mechanical stability. To address this, we developed SeizEAR, a standardized, three-size in-ear EEG system using paste-based electrodes with cross-ear referencing. Methods: This pilot study evaluated SeizEAR devices featuring small, medium, and large earpieces with superior and inferior paste-based electrodes in each ear, configured in a cross-ear reference scheme. It included five healthy adults who underwent recording sessions of approximately three hours (2.4 to 3.3 h). Electrode impedance was monitored against the acquisition system’s threshold indicator, with simultaneous scalp EEG from T7/T8 electrodes serving as the reference. Participants rated comfort on a 0–5 Likert scale every 30 min. Results: In-ear recordings showed moderate, band-dependent correspondence with ipsilateral temporal scalp electrodes, strongest in the delta and alpha bands and weakest in beta, and correspondence was consistently higher against a geometrically matched T7–T8 bipolar derivation than against a single referenced electrode. In-ear alpha reactivity to eye closure was present but attenuated relative to scalp. Comfort ratings remained high over the final two hours of wear, with no reported adverse events. Conclusions: SeizEAR acquired in-ear EEG that corresponded moderately with temporal scalp EEG and was well-tolerated over multi-hour wear in healthy adults. These preliminary findings support further development of a standardized in-ear EEG system and require confirmation in an adequately powered sample.
Open AccessA Pilot Study of the Feasibility of In-Ear EEG for Long-Term Temporal Lobe Brain Wave Monitoring
Background: Traditional scalp electroencephalography (EEG), though clinically validated, presents significant limitations, including lengthy setup, patient discomfort, and limited mobility. These factors hinder its utility for long-term ambulatory monitoring. In-ear EEG offers a promising alternative by leveraging the ear canal’s anatomical proximity to the temporal lobes and natural mechanical stability. To address this, we developed SeizEAR, a standardized, three-size in-ear EEG system using paste-based electrodes with cross-ear referencing. Methods: This pilot study evaluated SeizEAR devices featuring small, medium, and large earpieces with superior and inferior paste-based electrodes in each ear, configured in a cross-ear reference scheme. It included five healthy adults who underwent recording sessions of approximately three hours (2.4 to 3.3 h). Electrode impedance was monitored against the acquisition system’s threshold indicator, with simultaneous scalp EEG from T7/T8 electrodes serving as the reference. Participants rated comfort on a 0–5 Likert scale every 30 min. Results: In-ear recordings showed moderate, band-dependent correspondence with ipsilateral temporal scalp electrodes, strongest in the delta and alpha bands and weakest in beta, and correspondence was consistently higher against a geometrically matched T7–T8 bipolar derivation than against a single referenced electrode. In-ear alpha reactivity to eye closure was present but attenuated relative to scalp. Comfort ratings remained high over the final two hours of wear, with no reported adverse events. Conclusions: SeizEAR acquired in-ear EEG that corresponded moderately with temporal scalp EEG and was well-tolerated over multi-hour wear in healthy adults. These preliminary findings support further development of a standardized in-ear EEG system and require confirmation in an adequately powered sample.
- Open Access
- 8 July 2026
- Published by MDPI AG in Bioengineering
- Vol. 13 (7) , 785
Feasibility Pilot of the LaceUp Compression–Weight Sleeve for Essential Tremor
Essential tremor (ET) often remains disabling despite pharmacologic, surgical, and stimulation-based options. This feasibility study evaluated LaceUp, a passive wearable sleeve combining soft compression with distributed embedded weight. Ten adults with ET completed a single laboratory visit with a fixed task battery under baseline, unweighted compression sleeve, wrist weight, and LaceUp conditions. Outcomes included wrist inertial measurement unit (IMU) tremor-band power (4–12 Hz), root mean square (RMS) jerk, digitized Archimedes spirals, handwriting, satisfaction/preference surveys, and follow-up Canadian Occupational Performance Measure (COPM) ratings. On the more-affected limb, LaceUp was associated with the largest median tremor-band power reduction (−32.9%) versus wrist weights (−25.3%) and the unweighted sleeve (−19.5%), while RMS jerk reductions were similar across conditions. Spiral and handwriting measures were heterogeneous and appeared most informative in participants with greater baseline severity. Six of nine participants who completed the preference ranking selected LaceUp as preferred. At follow-up, two of six reported continued use, and one exceeded the commonly cited 2-point COPM satisfaction threshold. Because this small pilot used a fixed order, effects cannot be separated from period, learning, expectancy, fatigue, behavioral adaptation, or measurement effects. Findings support feasibility and identify candidate endpoints, severity-based enrollment considerations, and operational constraints for future studies.
- 8 July 2026
- Published by MDPI AG in Bioengineering
- Vol. 13 (7) , 785
Open AccessFeasibility Pilot of the LaceUp Compression–Weight Sleeve for Essential Tremor
Essential tremor (ET) often remains disabling despite pharmacologic, surgical, and stimulation-based options. This feasibility study evaluated LaceUp, a passive wearable sleeve combining soft compression with distributed embedded weight. Ten adults with ET completed a single laboratory visit with a fixed task battery under baseline, unweighted compression sleeve, wrist weight, and LaceUp conditions. Outcomes included wrist inertial measurement unit (IMU) tremor-band power (4–12 Hz), root mean square (RMS) jerk, digitized Archimedes spirals, handwriting, satisfaction/preference surveys, and follow-up Canadian Occupational Performance Measure (COPM) ratings. On the more-affected limb, LaceUp was associated with the largest median tremor-band power reduction (−32.9%) versus wrist weights (−25.3%) and the unweighted sleeve (−19.5%), while RMS jerk reductions were similar across conditions. Spiral and handwriting measures were heterogeneous and appeared most informative in participants with greater baseline severity. Six of nine participants who completed the preference ranking selected LaceUp as preferred. At follow-up, two of six reported continued use, and one exceeded the commonly cited 2-point COPM satisfaction threshold. Because this small pilot used a fixed order, effects cannot be separated from period, learning, expectancy, fatigue, behavioral adaptation, or measurement effects. Findings support feasibility and identify candidate endpoints, severity-based enrollment considerations, and operational constraints for future studies.
- Open Access
- 30 June 2026
- Published by MDPI AG in Bioengineering
- Vol. 13 (7) , 766
Objective Biomarker Development for Parameter Optimization in Neuromodulation Using High-Density EMG Temporal and Spatial Features
Transcutaneous spinal cord stimulation (tSCS) is a promising neuromodulation approach for motor recovery after spinal cord injury (SCI), yet clinical programming remains largely dependent on subjective parameter selection. This study evaluated high-density surface EMG (HD-sEMG)–derived spatial and temporal features as objective biomarkers for tSCS optimization in three adults with chronic cervical SCI. A 64-channel electrode array recorded stimulation-evoked responses across five cervical stimulation levels, four pulse widths, and graded amplitudes. Features describing activation magnitude, spatial distribution, cluster morphology, and temporal dynamics were extracted from epoch-based activation maps. Of the three enrolled participants, two demonstrated measurable stimulation-evoked responses and contributed to the paired-pulse analyses, whereas pulse-width analyses were limited to a single responsive muscle (left flexor carpi) in one participant. Paired-pulse analysis identified root mean square (RMS) as the most discriminative feature, revealing nonlinear, muscle- and level-specific dose–response relationships in which maximal suppression often occurred at intermediate rather than maximal amplitudes. Increasing pulse width expanded the spatial extent of recruitment (active area: p = 0.006; convex hull area: p = 0.004) without altering response timing. Polarity reversal analysis demonstrated stable innervation zone localization across stimulation levels and amplitudes. These findings establish a spatially resolved HD-sEMG framework that may support individualized tSCS parameter selection in SCI.
- 30 June 2026
- Published by MDPI AG in Bioengineering
- Vol. 13 (7) , 766
Open AccessObjective Biomarker Development for Parameter Optimization in Neuromodulation Using High-Density EMG Temporal and Spatial Features
Transcutaneous spinal cord stimulation (tSCS) is a promising neuromodulation approach for motor recovery after spinal cord injury (SCI), yet clinical programming remains largely dependent on subjective parameter selection. This study evaluated high-density surface EMG (HD-sEMG)–derived spatial and temporal features as objective biomarkers for tSCS optimization in three adults with chronic cervical SCI. A 64-channel electrode array recorded stimulation-evoked responses across five cervical stimulation levels, four pulse widths, and graded amplitudes. Features describing activation magnitude, spatial distribution, cluster morphology, and temporal dynamics were extracted from epoch-based activation maps. Of the three enrolled participants, two demonstrated measurable stimulation-evoked responses and contributed to the paired-pulse analyses, whereas pulse-width analyses were limited to a single responsive muscle (left flexor carpi) in one participant. Paired-pulse analysis identified root mean square (RMS) as the most discriminative feature, revealing nonlinear, muscle- and level-specific dose–response relationships in which maximal suppression often occurred at intermediate rather than maximal amplitudes. Increasing pulse width expanded the spatial extent of recruitment (active area: p = 0.006; convex hull area: p = 0.004) without altering response timing. Polarity reversal analysis demonstrated stable innervation zone localization across stimulation levels and amplitudes. These findings establish a spatially resolved HD-sEMG framework that may support individualized tSCS parameter selection in SCI.
- 19 May 2026
- Published by SAGE Publications in Technology and Disability
- Vol. 38 (4) , 403-412
A pilot study examining the impact of electrode configuration in transcutaneous spinal cord stimulation in spinal cord injury
Study design: Prospective trial. Objective: To evaluate the impact on muscle activation of different anatomical configurations of transcutaneous spinal cord stimulation electrodes amongst SCI and control patients. Summary of background data: Spinal cord stimulation has garnered increased attention as a promising treatment for spinal cord injury (SCI). However, existing studies on transcutaneous spinal cord stimulation consist of highly variable methodologies and lack standard protocols. Methods: Two adult SCI participants (PS01—T12 AIS D, and PS02—T2 AIS B) and two healthy adult controls (PS03, and PS04) were prospectively enrolled after IRB approval. Electromyography was used to record activity in the bilateral tibialis anterior (TA) and biceps femoris (BF). Four electrode configurations were trialed—cathode placement only at T11-T12 (montage T11-T12) versus combined configurations with cathodes at T11-T12 and at L1-L2, L3-L4, or S1-S2; anode placement was always at the bilateral iliac crests. Motor response was defined as EMG change >20 μV, as defined in the literature. Results: SCI participants exhibited overall decreased motor responses compared to controls, other than PS01 at the T11-T12 montage. The majority of motor responses from SCI participants did not meet the 20 µV threshold, and did not show the same consistent cranial to caudal pattern. PS01’s highest response was at T11-T12/L1-L2 (BF: 265.52 µV), whereas PS02 was highest at T11-T12 (TA: 39.73 µV). Overall, the motor response from the motor complete SCI (PS02—T2 AIS B) was substantially less than the motor response from the motor and sensory incomplete SCI. Conclusion: When performing transcutaneous spinal cord stimulation, the magnitude of motor response appears to vary with both the exact anatomical electrode configuration and the presence/severity of SCI. SCI participants demonstrated generally decreased motor responses, and a less predictable topographic pattern. Further work is needed to determine the ideal electrode configurations for different patients and spinal cord injury types.
- 19 May 2026
- Published by SAGE Publications in Technology and Disability
- Vol. 38 (4) , 403-412
A pilot study examining the impact of electrode configuration in transcutaneous spinal cord stimulation in spinal cord injury
Study design: Prospective trial. Objective: To evaluate the impact on muscle activation of different anatomical configurations of transcutaneous spinal cord stimulation electrodes amongst SCI and control patients. Summary of background data: Spinal cord stimulation has garnered increased attention as a promising treatment for spinal cord injury (SCI). However, existing studies on transcutaneous spinal cord stimulation consist of highly variable methodologies and lack standard protocols. Methods: Two adult SCI participants (PS01—T12 AIS D, and PS02—T2 AIS B) and two healthy adult controls (PS03, and PS04) were prospectively enrolled after IRB approval. Electromyography was used to record activity in the bilateral tibialis anterior (TA) and biceps femoris (BF). Four electrode configurations were trialed—cathode placement only at T11-T12 (montage T11-T12) versus combined configurations with cathodes at T11-T12 and at L1-L2, L3-L4, or S1-S2; anode placement was always at the bilateral iliac crests. Motor response was defined as EMG change >20 μV, as defined in the literature. Results: SCI participants exhibited overall decreased motor responses compared to controls, other than PS01 at the T11-T12 montage. The majority of motor responses from SCI participants did not meet the 20 µV threshold, and did not show the same consistent cranial to caudal pattern. PS01’s highest response was at T11-T12/L1-L2 (BF: 265.52 µV), whereas PS02 was highest at T11-T12 (TA: 39.73 µV). Overall, the motor response from the motor complete SCI (PS02—T2 AIS B) was substantially less than the motor response from the motor and sensory incomplete SCI. Conclusion: When performing transcutaneous spinal cord stimulation, the magnitude of motor response appears to vary with both the exact anatomical electrode configuration and the presence/severity of SCI. SCI participants demonstrated generally decreased motor responses, and a less predictable topographic pattern. Further work is needed to determine the ideal electrode configurations for different patients and spinal cord injury types.
- Open Access
- 7 January 2026
- Published by JMIR Publications Inc. in JMIR Aging
- Vol. 9, e82092
The Virtual Kitchen Challenge—Version 2: Validation of a Digital Assessment of Everyday Function in Older Adults
Background: Conventional methods of functional assessment include subjective self- or informant report, which may be biased by personal characteristics, cognitive abilities, and lack of standardization (eg, influence of idiosyncratic task demands). Traditional performance-based assessments offer some advantages over self- or informant reports but are time-consuming to administer and score. Objective: This study aims to evaluate the validity and reliability of the Virtual Kitchen Challenge—Version 2 (VKC-2), an objective, standardized, and highly efficient alternative to current functional assessments for older adults across the spectrum of cognitive aging, from preclinical to mild dementia. Methods: A total of 236 community-dwelling, diverse older adults completed a comprehensive neuropsychological evaluation to classify cognitive status as healthy, mild cognitive impairment, or mild dementia, after adjustment for demographic variables (age, education, sex, and estimated IQ). Participants completed 2 everyday tasks (breakfast and lunch) in a virtual kitchen (VKC-2) using a touchscreen interface to select objects and sequence steps. Automated scoring reflected completion time and performance efficiency (eg, number of screen interactions, percentage of time spent off-screen, interactions with distractor objects). Participants also completed the VKC-2 tasks using real objects (Real Kitchen). All participants and informants for 219 participants completed questionnaires regarding everyday function. A subsample of participants (n=143) performed the VKC-2 again in a second session, 4-6 weeks after the baseline, for retest analyses. Analyses evaluated construct and convergent validity, as well as retest and internal reliability, of VKC-2 automated scores. Results: A principal component analysis showed that the primary VKC-2 automated scores captured a single dimension and could be combined into a composite score reflecting task efficiency. Construct validity was supported by analyses of covariance results showing that participants with healthy cognition obtained significantly better VKC-2 scores than participants with cognitive impairment (all Ps<.001), even after controlling for demographics and general computer visuomotor dexterity. Convergent validity was supported by significant correlations between VKC-2 scores and performance on the Real Kitchen (r=−0.58 to 0.64, Ps<.001), conventional cognitive test scores (r=−0.50 to −0.22, Ps<.001), and self- and informant report questionnaires evaluating everyday function (r=0.25 to 0.43, Ps<.001). Intraclass correlation coefficients (ICCs) indicated moderate to excellent retest reliability (ICC=0.70-0.90) for VKC-2 scores after 4-6 weeks. Reliability improved in analyses including only participants who reported no change in cognitive status between time 1 and time 2 (n=123). Spearman-Brown correlations showed acceptable to good internal consistency between the VKC-2 tasks (breakfast and lunch) for all scores (0.77-0.84), supporting the use of total scores. Conclusions: The VKC-2 is an efficient, valid, and sensitive measure of everyday function for diverse older adults and holds promise to improve the status quo of functional assessment in aging, particularly when informants are unavailable or unreliable.
- 7 January 2026
- Published by JMIR Publications Inc. in JMIR Aging
- Vol. 9, e82092
Open AccessThe Virtual Kitchen Challenge—Version 2: Validation of a Digital Assessment of Everyday Function in Older Adults
Background: Conventional methods of functional assessment include subjective self- or informant report, which may be biased by personal characteristics, cognitive abilities, and lack of standardization (eg, influence of idiosyncratic task demands). Traditional performance-based assessments offer some advantages over self- or informant reports but are time-consuming to administer and score. Objective: This study aims to evaluate the validity and reliability of the Virtual Kitchen Challenge—Version 2 (VKC-2), an objective, standardized, and highly efficient alternative to current functional assessments for older adults across the spectrum of cognitive aging, from preclinical to mild dementia. Methods: A total of 236 community-dwelling, diverse older adults completed a comprehensive neuropsychological evaluation to classify cognitive status as healthy, mild cognitive impairment, or mild dementia, after adjustment for demographic variables (age, education, sex, and estimated IQ). Participants completed 2 everyday tasks (breakfast and lunch) in a virtual kitchen (VKC-2) using a touchscreen interface to select objects and sequence steps. Automated scoring reflected completion time and performance efficiency (eg, number of screen interactions, percentage of time spent off-screen, interactions with distractor objects). Participants also completed the VKC-2 tasks using real objects (Real Kitchen). All participants and informants for 219 participants completed questionnaires regarding everyday function. A subsample of participants (n=143) performed the VKC-2 again in a second session, 4-6 weeks after the baseline, for retest analyses. Analyses evaluated construct and convergent validity, as well as retest and internal reliability, of VKC-2 automated scores. Results: A principal component analysis showed that the primary VKC-2 automated scores captured a single dimension and could be combined into a composite score reflecting task efficiency. Construct validity was supported by analyses of covariance results showing that participants with healthy cognition obtained significantly better VKC-2 scores than participants with cognitive impairment (all Ps<.001), even after controlling for demographics and general computer visuomotor dexterity. Convergent validity was supported by significant correlations between VKC-2 scores and performance on the Real Kitchen (r=−0.58 to 0.64, Ps<.001), conventional cognitive test scores (r=−0.50 to −0.22, Ps<.001), and self- and informant report questionnaires evaluating everyday function (r=0.25 to 0.43, Ps<.001). Intraclass correlation coefficients (ICCs) indicated moderate to excellent retest reliability (ICC=0.70-0.90) for VKC-2 scores after 4-6 weeks. Reliability improved in analyses including only participants who reported no change in cognitive status between time 1 and time 2 (n=123). Spearman-Brown correlations showed acceptable to good internal consistency between the VKC-2 tasks (breakfast and lunch) for all scores (0.77-0.84), supporting the use of total scores. Conclusions: The VKC-2 is an efficient, valid, and sensitive measure of everyday function for diverse older adults and holds promise to improve the status quo of functional assessment in aging, particularly when informants are unavailable or unreliable.
- Open Access
- 4 November 2025
- Published by Springer Nature in Current Physical Medicine and Rehabilitation Reports
- Vol. 13 (1) , 1-10
Recent Advances in Vagus Nerve Stimulation for Stroke Rehabilitation
Purpose of Review: This review synthesizes recent developments in vagus nerve stimulation (VNS) for stroke rehabilitation from 2021–2025, emphasizing the transition from experimental approaches to clinical implementation following FDA approval of implantable VNS. Recent Findings: The 2021 FDA approval of the Vivistim Paired VNS System marked a watershed moment in stroke neuromodulation, providing the first regulatory-approved VNS therapy for upper extremity motor recovery. Long-term follow-up studies demonstrate sustained benefits at one year, with 66% of patients achieving clinically meaningful improvements. Concurrently, investigational transcutaneous approaches continue to evolve, though they remain limited by protocol heterogeneity and anatomical specificity concerns. Summary: Implantable VNS paired with rehabilitation represents a paradigm shift in stroke care, offering evidence-based neuromodulation therapy for patients with chronic upper limb impairment. While transcutaneous approaches show promise in research settings, their clinical translation requires standardization and larger controlled trials. Current evidence strongly supports implantable VNS as a viable therapeutic option for carefully selected patients, while highlighting the importance of distinguishing proven treatments from investigational approaches in clinical practice.
- 4 November 2025
- Published by Springer Nature in Current Physical Medicine and Rehabilitation Reports
- Vol. 13 (1) , 1-10
Open AccessRecent Advances in Vagus Nerve Stimulation for Stroke Rehabilitation
Purpose of Review: This review synthesizes recent developments in vagus nerve stimulation (VNS) for stroke rehabilitation from 2021–2025, emphasizing the transition from experimental approaches to clinical implementation following FDA approval of implantable VNS. Recent Findings: The 2021 FDA approval of the Vivistim Paired VNS System marked a watershed moment in stroke neuromodulation, providing the first regulatory-approved VNS therapy for upper extremity motor recovery. Long-term follow-up studies demonstrate sustained benefits at one year, with 66% of patients achieving clinically meaningful improvements. Concurrently, investigational transcutaneous approaches continue to evolve, though they remain limited by protocol heterogeneity and anatomical specificity concerns. Summary: Implantable VNS paired with rehabilitation represents a paradigm shift in stroke care, offering evidence-based neuromodulation therapy for patients with chronic upper limb impairment. While transcutaneous approaches show promise in research settings, their clinical translation requires standardization and larger controlled trials. Current evidence strongly supports implantable VNS as a viable therapeutic option for carefully selected patients, while highlighting the importance of distinguishing proven treatments from investigational approaches in clinical practice.
- 19 September 2025
- Published by SAGE Publications in Journal of Geriatric Psychiatry and Neurology
- Vol. 39 (4) , 426-430
Intranasal Oxytocin for Managing Agitation in a Patient of Mixed Dementia With Multiple Pathologies, Particularly With a History of Repetitive Head Injuries
Background: Agitation is common in persons living with dementia (major neurocognitive disorder) and worsens with disease progression. Brexpiprazole is the sole FDA-approved drug for agitation in persons with Alzheimer’s dementia, but requires daily dosing over weeks. Limited pharmacologic options exist for acute agitation management. Purpose: To show the efficacy of oxytocin for acute agitation management in dementia patients. Case: We report a 70-year-old former professional wrestler with repetitive head trauma who developed dementia and severe agitation. He showed remarkable, rapid improvement with as-needed intranasal oxytocin 30 IU until his death. Post-mortem examination revealed mixed pathology: Alzheimer’s disease (Intermediate stage), Lewy Body disease (Limbic/Transitional stage), cerebrovascular disease with multiple infarcts, and chronic traumatic encephalopathy. Conclusion: This case demonstrates the potential efficacy of intranasal oxytocin for acute agitation management in persons living with mixed dementia and may inspire further investigation.
- 19 September 2025
- Published by SAGE Publications in Journal of Geriatric Psychiatry and Neurology
- Vol. 39 (4) , 426-430
Intranasal Oxytocin for Managing Agitation in a Patient of Mixed Dementia With Multiple Pathologies, Particularly With a History of Repetitive Head Injuries
Background: Agitation is common in persons living with dementia (major neurocognitive disorder) and worsens with disease progression. Brexpiprazole is the sole FDA-approved drug for agitation in persons with Alzheimer’s dementia, but requires daily dosing over weeks. Limited pharmacologic options exist for acute agitation management. Purpose: To show the efficacy of oxytocin for acute agitation management in dementia patients. Case: We report a 70-year-old former professional wrestler with repetitive head trauma who developed dementia and severe agitation. He showed remarkable, rapid improvement with as-needed intranasal oxytocin 30 IU until his death. Post-mortem examination revealed mixed pathology: Alzheimer’s disease (Intermediate stage), Lewy Body disease (Limbic/Transitional stage), cerebrovascular disease with multiple infarcts, and chronic traumatic encephalopathy. Conclusion: This case demonstrates the potential efficacy of intranasal oxytocin for acute agitation management in persons living with mixed dementia and may inspire further investigation.
- Open Access
The Virtual Kitchen Challenge–Version 2: Validation of a Digital Assessment of Everyday Function in Older Adults
Background: Conventional methods of functional assessment include subjective self/informant-report, which may be biased by personal characteristics, cognitive abilities, and lack of standardization (e.g., influenced by idiosyncratic task demands). Traditional performance-based assessments offer some advantages over self/informant reports, but they are time consuming to administer and score. Objective: To evaluate the validity and reliability of the Virtual Kitchen Challenge -Version 2 (VKC-2), an objective, standardized, and highly efficient alternative to current functional assessments for older adults across the spectrum of cognitive aging, from preclinical to mild dementia. Methods: 236 community-dwelling diverse older adults completed a comprehensive neuropsychological evaluation to classify their cognitive abilities as healthy, mild cognitive impairment or mild dementia, after adjustment of demographic variables (age, education, sex, estimated IQ). Participants were administered the VKC-2, which required completion of two everyday tasks (breakfast, lunch) in a virtual kitchen using a touch-screen interface to select objects and sequence steps. Automated scoring reflected completion time and performance efficiency (e.g., number of screen interactions, % time spent off screen, interactions with distractor objects). Participants also completed the VKC-2 tasks using real objects (Real Kitchen) and questionnaires of everyday function. Informants for 219 participants completed questionnaires regarding everyday function. A subsample of participants (n = 143) performed the VKC-2 again in a second session 4-6 weeks after the baseline for retest analyses. Analyses evaluated construct and convergent validity and retest and internal reliability of VKC-2 automated scores. Results: Construct validity was supported by ANCOVA results showing participants with healthy cognition obtained significantly better VKC-2 scores than participants with cognitive impairment (all ps < .001), even after controlling for demographics and general computer visuomotor dexterity. Convergent validity was supported by significant correlations between VKC-2 scores and performance on the Real Kitchen (r values = -.58 to .64, ps < .001), conventional cognitive test scores (r values = -.50 to -.22, ps < .001), and to self and informant questionnaires evaluating everyday function (r values = .25 to .43, ps < .001). Retest reliability was strong as evidenced by high intraclass correlations between VKC-2 scores across the two timepoints (κ = 0.27, p < .001). Reliability improved in analyses including only participants who reported no change in cognitive status between time 1 and time 2 (n=123). Spearman-Brown correlations showed acceptable to good internal consistency between the VKC-2 tasks (breakfast, lunch) for all scores (.77 to .81) supporting the use of total scores. Conclusions: The VKC-2 is an efficient, valid, and sensitive measure of everyday function for diverse older adults that may be used for large scale longitudinal studies, clinical trials, and clinical assessments. The VKC-2 holds promise to improve the status quo of functional assessment in aging particularly when informants are unavailable or unreliable.
Open AccessThe Virtual Kitchen Challenge–Version 2: Validation of a Digital Assessment of Everyday Function in Older Adults
Background: Conventional methods of functional assessment include subjective self/informant-report, which may be biased by personal characteristics, cognitive abilities, and lack of standardization (e.g., influenced by idiosyncratic task demands). Traditional performance-based assessments offer some advantages over self/informant reports, but they are time consuming to administer and score. Objective: To evaluate the validity and reliability of the Virtual Kitchen Challenge -Version 2 (VKC-2), an objective, standardized, and highly efficient alternative to current functional assessments for older adults across the spectrum of cognitive aging, from preclinical to mild dementia. Methods: 236 community-dwelling diverse older adults completed a comprehensive neuropsychological evaluation to classify their cognitive abilities as healthy, mild cognitive impairment or mild dementia, after adjustment of demographic variables (age, education, sex, estimated IQ). Participants were administered the VKC-2, which required completion of two everyday tasks (breakfast, lunch) in a virtual kitchen using a touch-screen interface to select objects and sequence steps. Automated scoring reflected completion time and performance efficiency (e.g., number of screen interactions, % time spent off screen, interactions with distractor objects). Participants also completed the VKC-2 tasks using real objects (Real Kitchen) and questionnaires of everyday function. Informants for 219 participants completed questionnaires regarding everyday function. A subsample of participants (n = 143) performed the VKC-2 again in a second session 4-6 weeks after the baseline for retest analyses. Analyses evaluated construct and convergent validity and retest and internal reliability of VKC-2 automated scores. Results: Construct validity was supported by ANCOVA results showing participants with healthy cognition obtained significantly better VKC-2 scores than participants with cognitive impairment (all ps < .001), even after controlling for demographics and general computer visuomotor dexterity. Convergent validity was supported by significant correlations between VKC-2 scores and performance on the Real Kitchen (r values = -.58 to .64, ps < .001), conventional cognitive test scores (r values = -.50 to -.22, ps < .001), and to self and informant questionnaires evaluating everyday function (r values = .25 to .43, ps < .001). Retest reliability was strong as evidenced by high intraclass correlations between VKC-2 scores across the two timepoints (κ = 0.27, p < .001). Reliability improved in analyses including only participants who reported no change in cognitive status between time 1 and time 2 (n=123). Spearman-Brown correlations showed acceptable to good internal consistency between the VKC-2 tasks (breakfast, lunch) for all scores (.77 to .81) supporting the use of total scores. Conclusions: The VKC-2 is an efficient, valid, and sensitive measure of everyday function for diverse older adults that may be used for large scale longitudinal studies, clinical trials, and clinical assessments. The VKC-2 holds promise to improve the status quo of functional assessment in aging particularly when informants are unavailable or unreliable.
- Open Access
- 12 August 2025
- Published by JMIR Publications Inc. in JMIR Preprints
The Virtual Kitchen Challenge—Version 2: Validation of a Digital Assessment of Everyday Function in Older Adults (Preprint)
BACKGROUND Conventional methods of functional assessment include subjective self- or informant report, which may be biased by personal characteristics, cognitive abilities, and lack of standardization (eg, influence of idiosyncratic task demands). Traditional performance-based assessments offer some advantages over self- or informant reports but are time-consuming to administer and score. OBJECTIVE This study aims to evaluate the validity and reliability of the Virtual Kitchen Challenge—Version 2 (VKC-2), an objective, standardized, and highly efficient alternative to current functional assessments for older adults across the spectrum of cognitive aging, from preclinical to mild dementia. METHODS A total of 236 community-dwelling, diverse older adults completed a comprehensive neuropsychological evaluation to classify cognitive status as healthy, mild cognitive impairment, or mild dementia, after adjustment for demographic variables (age, education, sex, and estimated IQ). Participants completed 2 everyday tasks (breakfast and lunch) in a virtual kitchen (VKC-2) using a touchscreen interface to select objects and sequence steps. Automated scoring reflected completion time and performance efficiency (eg, number of screen interactions, percentage of time spent off-screen, interactions with distractor objects). Participants also completed the VKC-2 tasks using real objects (Real Kitchen). All participants and informants for 219 participants completed questionnaires regarding everyday function. A subsample of participants (n=143) performed the VKC-2 again in a second session, 4-6 weeks after the baseline, for retest analyses. Analyses evaluated construct and convergent validity, as well as retest and internal reliability, of VKC-2 automated scores. RESULTS A principal component analysis showed that the primary VKC-2 automated scores captured a single dimension and could be combined into a composite score reflecting task efficiency. Construct validity was supported by analyses of covariance results showing that participants with healthy cognition obtained significantly better VKC-2 scores than participants with cognitive impairment (all Ps<.001), even after controlling for demographics and general computer visuomotor dexterity. Convergent validity was supported by significant correlations between VKC-2 scores and performance on the Real Kitchen (r=−0.58 to 0.64, Ps<.001), conventional cognitive test scores (r=−0.50 to −0.22, Ps<.001), and self- and informant report questionnaires evaluating everyday function (r=0.25 to 0.43, Ps<.001). Intraclass correlation coefficients (ICCs) indicated moderate to excellent retest reliability (ICC=0.70-0.90) for VKC-2 scores after 4-6 weeks. Reliability improved in analyses including only participants who reported no change in cognitive status between time 1 and time 2 (n=123). Spearman-Brown correlations showed acceptable to good internal consistency between the VKC-2 tasks (breakfast and lunch) for all scores (0.77-0.84), supporting the use of total scores. CONCLUSIONS The VKC-2 is an efficient, valid, and sensitive measure of everyday function for diverse older adults and holds promise to improve the status quo of functional assessment in aging, particularly when informants are unavailable or unreliable.
- 12 August 2025
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessThe Virtual Kitchen Challenge—Version 2: Validation of a Digital Assessment of Everyday Function in Older Adults (Preprint)
BACKGROUND Conventional methods of functional assessment include subjective self- or informant report, which may be biased by personal characteristics, cognitive abilities, and lack of standardization (eg, influence of idiosyncratic task demands). Traditional performance-based assessments offer some advantages over self- or informant reports but are time-consuming to administer and score. OBJECTIVE This study aims to evaluate the validity and reliability of the Virtual Kitchen Challenge—Version 2 (VKC-2), an objective, standardized, and highly efficient alternative to current functional assessments for older adults across the spectrum of cognitive aging, from preclinical to mild dementia. METHODS A total of 236 community-dwelling, diverse older adults completed a comprehensive neuropsychological evaluation to classify cognitive status as healthy, mild cognitive impairment, or mild dementia, after adjustment for demographic variables (age, education, sex, and estimated IQ). Participants completed 2 everyday tasks (breakfast and lunch) in a virtual kitchen (VKC-2) using a touchscreen interface to select objects and sequence steps. Automated scoring reflected completion time and performance efficiency (eg, number of screen interactions, percentage of time spent off-screen, interactions with distractor objects). Participants also completed the VKC-2 tasks using real objects (Real Kitchen). All participants and informants for 219 participants completed questionnaires regarding everyday function. A subsample of participants (n=143) performed the VKC-2 again in a second session, 4-6 weeks after the baseline, for retest analyses. Analyses evaluated construct and convergent validity, as well as retest and internal reliability, of VKC-2 automated scores. RESULTS A principal component analysis showed that the primary VKC-2 automated scores captured a single dimension and could be combined into a composite score reflecting task efficiency. Construct validity was supported by analyses of covariance results showing that participants with healthy cognition obtained significantly better VKC-2 scores than participants with cognitive impairment (all Ps<.001), even after controlling for demographics and general computer visuomotor dexterity. Convergent validity was supported by significant correlations between VKC-2 scores and performance on the Real Kitchen (r=−0.58 to 0.64, Ps<.001), conventional cognitive test scores (r=−0.50 to −0.22, Ps<.001), and self- and informant report questionnaires evaluating everyday function (r=0.25 to 0.43, Ps<.001). Intraclass correlation coefficients (ICCs) indicated moderate to excellent retest reliability (ICC=0.70-0.90) for VKC-2 scores after 4-6 weeks. Reliability improved in analyses including only participants who reported no change in cognitive status between time 1 and time 2 (n=123). Spearman-Brown correlations showed acceptable to good internal consistency between the VKC-2 tasks (breakfast and lunch) for all scores (0.77-0.84), supporting the use of total scores. CONCLUSIONS The VKC-2 is an efficient, valid, and sensitive measure of everyday function for diverse older adults and holds promise to improve the status quo of functional assessment in aging, particularly when informants are unavailable or unreliable.