YNYunfei Niu

Yunfei Niu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yunfei Niu has a total of 60 co-authors. Here are the top co-authors by number of shared publications:

  • Chun-Cai Zhang

    Department of Emergency and Trauma, Shanghai Changhai Hospital Affiliated to Second Military Medical University, Shanghai, China

    4 shared publications
  • Dawei He

    Department of orthopaedics, Changhai Hospital, Second Military Medical University, Shanghai 200433, China

    3 shared publications
  • Han Guo

    Shanghai Synchrotron Radiation Facility, Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800, China

    3 shared publications
  • Jiacan Su

    Department of orthopaedics, Changhai Hospital, Second Military Medical University, Shanghai 200433, China

    3 shared publications
  • Jie Wei

    Engineering Research Center for Biomedicial Materials of Ministry of Education, East China University of Science and Technology, Shanghai 200237, China

    3 shared publications
  • Baoqing Yu

    Department of orthopaedics, Changhai Hospital, Second Military Medical University, Shanghai 200433, China

    2 shared publications

Latest Publications

  • Bioactive and degradable scaffolds of the mesoporous bioglass and poly( l -lactide) composite for bone tissue regeneration

    by Yunfei Niu, Lieping Guo, Jun Liu, Hongxing Shen, Jiacan Su, Xiaofei An, Baoqing Yu, Jie Wei, Jung-Woog Shin, Han Guo, et al.

    Bioactive scaffolds of the mesoporous bioglass (m-BG) and poly(L-lactide) (PLLA) composite were fabricated using a solvent casting-particulate leaching method. The results showed that incorporation of the m-BG into PLLA significantly improved the in vitro water absorption, degradability and apatite-formation ability of the m-BG–PLLA composite scaffolds, which were m-BG content dependent. Moreover, addition of the m-BG into PLLA could neutralize the acidic degradation products of PLLA and thus compensate for the decrease of the pH value. In cell culture experiments, the results revealed that the m-BG–PLLA composite scaffolds enhanced attachment, proliferation and alkaline phosphatase (ALP) activity of MC3T3-E1 cells, which were m-BG content dependent. In animal experiments, the SRmCT and histological elevation results showed that the composite scaffolds significantly improved osteogenesis in vivo. It can be suggested that incorporation of bioactive materials of m-BG into PLLA was a useful approach to obtain composite scaffolds with improved properties (such as water absorption, degradability, bioactivity and osteogenesis), and the composite scaffolds with excellent biocompatibility could be promising bioactive implants for bone regeneration.


  • Open Access

    Mesoporous magnesium silicate-incorporated poly(ε-caprolactone)-poly(ethylene glycol)- poly(ε-caprolactone) bioactive composite beneficial to osteoblast behaviors

    by Yunfei Niu, Wei Dong, Han Guo, Yuhu Deng, Lieping Guo, Xiaofei An, Dawei He, Jie Wei, Ming Li

    Mesoporous magnesium silicate (m-MS) and poly(ε-caprolactone)-poly(ethylene glycol)-poly(ε-caprolactone) (PCL-PEG-PCL) composite (m-MPC) was synthesized by solvent casting method. The results suggest that the mechanical properties of compressive strength and elastic modulus, as well as hydrophilicity, of the m-MPC increased with increase of m-MS content in the composites. In addition, the weight loss of the m-MPC improved significantly with the increase of m-MS content during composite soaking in phosphate-buffered saline for 10 weeks, indicating that incorporation of m-MS into PCL-PEG-PCL could enhance the degradability of the m-MPC. Moreover, the m-MPC with 40 w% m-MS could induce a dense and continuous apatite layer on its surface after soaking in simulated body fluid for 5 days, which was better than m-MPC 20 w% m-MS, exhibiting excellent in vitro bioactivity. In cell cultural experiments, the results showed that the attachment and viability ratio of MG63 cells on m-MPC increased significantly with the increase of m-MS content, showing that the addition of m-MS into PCL-PEG-PCL could promote cell attachment and proliferation. The results suggest that the incorporation of m-MS into PCL-PEG-PCL could produce bioactive composites with improved hydrophilicity, degradability, bioactivity, and cytocompatibility.


  • Tissue engineering scaffolds of mesoporous magnesium silicate and poly(ε-caprolactone)–poly(ethylene glycol)–poly(ε-caprolactone) composite

    by Dawei He, Wei Dong, Songchao Tang, Jie Wei, Zhenghui Liu, Xiaojiang Gu, Ming Li, Han Guo, Yunfei Niu

    Mesoporous magnesium silicate (m-MS) and poly(ε-caprolactone)–poly(ethylene glycol)–poly(ε-caprolactone) (PCL–PEG–PCL) composite scaffolds were fabricated by solvent-casting and particulate leaching method. The results suggested that the incorporation of m-MS into PCL–PEG–PCL could significantly improve the water adsorption of the m-MS/PCL–PEG–PCL composite (m-MPC) scaffolds. The in vitro degradation behavior of m-MPC scaffolds were determined by testing weight loss of the scaffolds after soaking into phosphate buffered saline (PBS), and the result showed that the degradation of m-MPC scaffolds was obviously enhanced by addition of m-MS into PCL–PEG–PCL after soaking for 10 weeks. Proliferation of MG63 cells on m-MPC was significantly higher than MPC scaffolds at 4 and 7 days. ALP activity on the m-MPC was obviously higher than MPC scaffolds at 7 days, revealing that m-MPC could promote cell differentiation. Histological evaluation showed that the introduction of m-MS into PCL–PEG–PCL enhanced the efficiency of new bone formation when the m-MPC scaffolds implanted into bone defect of rabbits. The results suggested that the inorganic/organic composite of m-MS and PCL–PEG–PCL scaffolds exhibited good biocompatibility, degradability and osteogenesis.


    • 1 December 2011
      • Vol. 25  (12) , 1422-5

    [Application of acetabular tridimensional memory alloy-fixation system in treatment of old acetabular posterior wall fracture with bone defect].

    by Liehu Cao, Guangquan Bao, Chuncai Zhang, Xinwei Liu, Yunfei Niu, Shuogui Xu, Jiacan Su

    To investigate the effectiveness of acetabular tridimensional memory alloy-fixation system (ATMFS) combined with autologous iliac bone in the treatment of old acetabular posterior wall fracture with bone defect. Between January 2002 and February 2009, 17 patients with old acetabular posterior wall fracture and bone defect were treated, including 11 males and 6 females with an average age of 41.7 years (range, 20-60 years). The time from fracture to admission was 14-180 days (mean, 63 days). The displacement of the acetabular articular surface was more than or equal to 3 mm. According to the America Association of Orthopedic Surgeon (AAOS) acetabular fracture and defect classification standard, there were 4 cases of type I, 6 cases of type II, 5 cases of type III, and 2 cases of type IV. After the residual fracture fragments of the acetabular posterior wall and soft tissue hyperplasia were removed, the femoral head was reduced, and posterior wall defect was repaired with autologous iliac bone graft; ATMFS was used to fix acetabular posterior wall and artificial capsular ligament to reconstruct the hip so as to prevent re-dislocation of the femoral head. According to Matta imaging assessment standard, the results were excellent in 8 cases, good in 6 cases, fair in 2 cases, and poor in 1 case with an excellent and good rate of 82.3%. All incisions healed by first intention, and no sciatic nerve injury occurred. All patients were followed up 1-8 years (mean, 3.9 years). The mean time of fracture union was 3.6 months (range, 2-6 months). Avascular necrosis of femoral head occurred in 1 case, heterotopic ossification around the acetabulum in 1 case. According to Merle d'Aubigné-Postel scoring system evaluation, the clinical results were excellent in 9 cases, good in 6 cases, fair in 1 case, and poor in 1 case with an excellent and good rate of 88.2%. ATMFS combined with autologous iliac bone graft and artificial ligament reconstruction of the hip joint capsule is a good choice for the treatment of old acetabular posterior wall fractures with bone defect, which can resume the posterior hip joint stability and prevent re-dislocation of the femoral head.

    • 1 February 2011
      • Vol. 24  (2) , 102-8

    [Design of ABC damage variable and positioning system for acetabular fractures and 1122 cases multi-center statistic analysis].

    by Chun-Cai Zhang, Shuo-Gui Xu, Bao-Qing Yu, Fang Ji, Qing-Ge Fu, Xin-Wei Liu, Yun-Tong Zhang, Yun-Fei Niu, Pan-Feng Wang, Jia-Can Su, et al.

    To design ABC damage variable and positioning system for acetabular fracture and explore the feasibility and clinical practical value of the system through the multi-center analysis of 1122 acetabular fractures. According to acetabular three-column conception, and pelvic ring lesions damage direction caused by acetabular fracture domino effect and injury degree of proximal femur joint, it defined class A as any column acetabular fracture; class B as any two-column acetabular fracture; class C as front, dome and posterior mixture acetabular fracture. Lower case English letters a, m, p represented front, dome, posterior fracture, respectively. Acetabular damage variables: 1 was simple displaced fractures; 2 was comminuted fractures; 3 was compression fractures. Pelvic ring lesions damage variables: alpha was sacroiliac joints or sacroiliac fracture horizontal separation deflection; beta was sacroiliac joints or sacroiliac fracture vertical separation deflection; gamma was pubic symphysis separation/superior and inferior ramus of pubis fracture deflection; alpha beta gamma delta was compound floating damage. Proximal humerus joint damage variables: I was femoral head fracture; II was femoral neck fracture; II was intertrochanteric fractures of femur; IV was I to III compound fracture. The ABC damage variable positioning system for acetabular fracture was made up by the above-mentioned variables. The statistics from March 1997 to February 2010 showed 1122 cases acetabular fractures with 18 cases of double side acetabular fracture and 1140 cases of acetabular fractures. The pelvics anterior-posterior view, ilium and obturator oblique view, and 2/3D-CT materials were analyzed and researched. Each damage variables distribution situation in 1140 cases of acetabular fracture involved A in 237 cases (20.8%), B in 605 cases (53.1%), C in 298 cases (26.1%);front column fracture in 808 cases(70.9%), dome fracture in 507 cases (44.5%), posterior fracture in 1026 cases (90%). Acetabular variables: variabe 1 in 203 cases of simple displaced fracture (17.8%); variabe 2 in 516 cases of comminuted fracture(45.3%); variabe 3 in 421 cases of compression fracture (36.9%); 249 cases of pelvic ring lesions damage (21.8%), 75 cases femoral head fracture (6.6%); 18 cases of double side acetabular fracture and relative pelvic ring and proximal humerus joint variables (1.58%). Key part and curative effect elements of 1140 cases acetabular fracture: 507 cases of dome or posterior acetabular fracture (44.5%); 421 cases of compression fracture (36.9%); 249 cases of pelvic ring variables (21.8%); 75 cases of proximal humerus joint variables (6.6%); 486 cases of simple Aa/pl/2,Bapl/2 acetabular fracture (42.6% ). Compression fracture, especially defected compression fracture, takes important part in acetabular damage variables, and also presents that acetabular fracture with pelvic ring and proximal femoral damage variables are not rare at all. The relationship of the acetabular fracture damage variables, and its percentage shows the key points and elements in clinical treatment: weight-bearing to dome accounts for 44.5%; compression to defects account for 36.9%, pelvic ring to float accounts for 21.8%; dome fracture to double side fracture account for 6.6%. The system has significant guiding effects on clinic in terms of evaluation of injury severity, anatomic localization, difficulty index, alternative strategy, operative approach, effect of treatment,and prognosis. And the most important thing is that the system creates the comparison of damage variables in same type of fracture and the communication of homo-language and explores a new method.

    • 1 January 2008
      • Vol. 22  (1) , 36-9

    [Reconstruction of condyle in treatment of refractory condylar nonunion and defect of humerus].

    by Yunfei Niu, Chuncai Zhang, Baoqing Yu, Shuogui Xu, Jialin Wang, Jiacan Su, Peng Zhang, Huapeng Guan, Xinwei Liu, Zhuodong Li

    To discuss the strategy of condylar reconstruction in the treatment of refractory condylar nonunion and defect of humerus. From September 1998 to September 2005, 18 patients with refractory condylar nonunion concomitant withdefect of humerus were treated. The series included 12 males and 6 females, aged 18 to 60 years. According to AO/ASIF system, primal fractures were classified, including 5 cases of type A3, 2 cases of type B1, 4 cases of type C2 and 7 cases of type C3 fractures. Condylar nonunion and defect of humerus were confirmed by preoperative X-ray. Defective bone mass was 1-4 cm2. The mean extension and flexion of elbow joint was 21.5 degrees (5-65 degrees) and 95.8 degrees (85.0-123.5 degrees) respectively. According to Cassebaum scoring system, the excellent and good rate was 27.8% (excellent in 1 case and good in 4 cases). Time from injury to operation averaged 22.8 months (7-52 months). All patients were operated with approach of olecranon osteotomy. Bone defect was reconstructed with iliac autograft. Shape memory compressive connector, Kirschner wire, cannulated nail, anatomic plates and reconstruction plates were used to fix. Eighteen patients were followed up 12-86 months (mean 27.6 months). All the incisions healed by first intention. No bone block displacement,loosening or breakage of internal fixation occurred. The time of bone union averaged 5.7 months (4-8 months). The mean extension and flexion of elbow joint were 11.4 degrees (0-44.5 degrees) and 128.6 degrees (105.5-144.5 degrees) 1 year after operation. Ectopicossification formed in 1 case at anterior part of elbow 4 months after operation. According to Cassebaum scoring system,the results were excellent in 8 cases, good in 6 cases, fair in 3 cases and poor in 1 case. The excellent and good rate was 77.8%. The shape of humeral condyle can be reconstructed with iliac autograft. Compressive internal fixation of bone block can promote bone union. Anatomical reconstruction, rigid internal fixation and early function exercise can improve the function of elbow joint evidently.