KHKyle S. Hardman

Kyle S. Hardman

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kyle S. Hardman has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Simultaneous Precision Gravimetry and Magnetic Gradiometry with a Bose-Einstein Condensate: A High Precision, Quantum Sensor

    by K. S. Hardman, P. J. Everitt, G. D. McDonald, P. Manju, P. B. Wigley, M. A. Sooriyabandara, C. C. N. Kuhn, J. E. Debs, J. D. Close, N. P. Robins

    A Bose-Einstein condensate is used as an atomic source for a high precision sensor. A 5×106  atom F=1 spinor condensate of Rb87 is released into free fall for up to 750 ms and probed with a T=130  ms Mach-Zehnder atom interferometer based on Bragg transitions. The Bragg interferometer simultaneously addresses the three magnetic states |mf=1,0,−1⟩, facilitating a simultaneous measurement of the acceleration due to gravity with a 1000 run precision of Δg/g=1.45×10−9 and the magnetic field gradient to a precision of 120  pT/m.


  • Open Access

    A quantum sensor: simultaneous precision gravimetry and magnetic gradiometry with a Bose-Einstein condensate

    by Kyle S. Hardman, Patrick J. Everitt, Gordon D. McDonald, Perumbil Manju, Paul B. Wigley, Mahasen A. Sooriyabadara, Carlos C. N. Kuhn, John E. Debs, John D. Close, Nicholas P. Robins

    A Bose-Einstein condensate is used as an atomic source for a high precision sensor. A $5\times 10^6$ atom F=1 spinor condensate of $^{87}$Rb is released into free fall for up to $750$ms and probed with a Mach-Zehnder atom interferometer based on Bragg transitions. The Bragg interferometer simultaneously addresses the three magnetic states, $\left| m_f=1,0,-1 \right\rangle$, facilitating a simultaneous measurement of the acceleration due to gravity with an asymptotic precision of $2.1\times 10^{-9}$$\Delta$g/g and the magnetic field gradient to a precision $8$pT/m.

  • Open Access

    Time-of-flight detection of ultra-cold atoms using resonant frequency modulation imaging

    by K. S. Hardman, P. B. Wigley, P. J. Everitt, P. Manju, C. C. N. Kuhn, N. P. Robins

    Resonant frequency modulation imaging is used to detect free falling ultra-cold atoms. A theoretical comparison of fluorescence imaging (FI) and frequency modulation imaging (FMI) is made, indicating that for low optical depth clouds, FMI accomplished a higher signal-to-noise ratio under conditions necessary for a 200 μm spatially resolved atom interferometer. A 750 ms time-of-flight measurement reveals near atom shot-noise limited number measurements of 2×106 Bose-condensed Rb87 atoms. The detection system is applied to high precision spinor BEC based atom interferometer.


  • Role of source coherence in atom interferometery

    by Kyle S. Hardman, Carlos C. N. Kuhn, Gordon D. McDonald, John E. Debs, Shayne Bennetts, John D. Close, Nicholas P. Robins

    The role of source cloud spatial coherence in a Mach-Zehnder-type atom interferometer is experimentally investigated. The visibility and contrast of a Bose-Einstein condensate (BEC) and three thermal sources with varying spatial coherence are compared as a function of interferometer time. At short times, the fringe visibility of a BEC source approaches 100% nearly independent of π pulse efficiency, while thermal sources have fringe visibilities limited to the π pulse efficiency. More importantly for precision measurement systems, the BEC source maintains interference at interferometer times significantly beyond the thermal source.


  • Open Access

    The Role of Source Coherence in Atom Interferometery

    by Kyle S. Hardman, Carlos C. N. Kuhn, Gordon D. McDonald, John E. Debs, Shayne Bennetts, John D. Close, Nicholas P. Robins

    The role of source cloud spatial coherence in a Mach-Zehnder type atom interferometer is experimentally investigated. The visibility and contrast of a Bose-Einstein condensate (BEC) and three thermal sources with varying spatial coherence are compared as a function of interferometer time. At short times, the fringe visibility of a BEC source approaches 100 % nearly independent of pi pulse efficiency, while thermal sources have fringe visibilities limited to the mirror efficiency. More importantly for precision measurement systems, the BEC source maintains interference at interferometer times significantly beyond the thermal source.