Kyle S. Hardman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kyle S. Hardman has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Carlos Noschang Kuhn
University of Canberra
3 shared publications John D. Close
Department of Quantum Science Quantum Sensors and Atomlaser Lab Australian National University 0200 Canberra Australia
3 shared publications- Nicholas P. Robins
Department of Quantum Science, The Australian National University, Canberra, ACT 0200, Australia
3 shared publications Carlos C. N. Kuhn
Department of Quantum Science Quantum Sensors and Atomlaser Lab Australian National University 0200 Canberra Australia
2 shared publicationsGordon D. McDonald
Department of Quantum Science Quantum Sensors and Atomlaser Lab Australian National University 0200 Canberra Australia
2 shared publications- Gordon D. McDonald
Quantum Sensors and Atomlaser Lab, Department of Quantum Science, Australian National University, Canberra 0200, Australia
2 shared publications
Latest Publications
- 21 September 2016
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 117 (13) , 138501
Simultaneous Precision Gravimetry and Magnetic Gradiometry with a Bose-Einstein Condensate: A High Precision, Quantum Sensor
A Bose-Einstein condensate is used as an atomic source for a high precision sensor. A spinor condensate of is released into free fall for up to 750 ms and probed with a Mach-Zehnder atom interferometer based on Bragg transitions. The Bragg interferometer simultaneously addresses the three magnetic states , facilitating a simultaneous measurement of the acceleration due to gravity with a 1000 run precision of and the magnetic field gradient to a precision of .- 21 September 2016
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 117 (13) , 138501
Simultaneous Precision Gravimetry and Magnetic Gradiometry with a Bose-Einstein Condensate: A High Precision, Quantum Sensor
A Bose-Einstein condensate is used as an atomic source for a high precision sensor. A spinor condensate of is released into free fall for up to 750 ms and probed with a Mach-Zehnder atom interferometer based on Bragg transitions. The Bragg interferometer simultaneously addresses the three magnetic states , facilitating a simultaneous measurement of the acceleration due to gravity with a 1000 run precision of and the magnetic field gradient to a precision of .- Open Access
A quantum sensor: simultaneous precision gravimetry and magnetic gradiometry with a Bose-Einstein condensate
A Bose-Einstein condensate is used as an atomic source for a high precision sensor. A $5\times 10^6$ atom F=1 spinor condensate of $^{87}$Rb is released into free fall for up to $750$ms and probed with a Mach-Zehnder atom interferometer based on Bragg transitions. The Bragg interferometer simultaneously addresses the three magnetic states, $\left| m_f=1,0,-1 \right\rangle$, facilitating a simultaneous measurement of the acceleration due to gravity with an asymptotic precision of $2.1\times 10^{-9}$$\Delta$g/g and the magnetic field gradient to a precision $8$pT/m.Open AccessA quantum sensor: simultaneous precision gravimetry and magnetic gradiometry with a Bose-Einstein condensate
A Bose-Einstein condensate is used as an atomic source for a high precision sensor. A $5\times 10^6$ atom F=1 spinor condensate of $^{87}$Rb is released into free fall for up to $750$ms and probed with a Mach-Zehnder atom interferometer based on Bragg transitions. The Bragg interferometer simultaneously addresses the three magnetic states, $\left| m_f=1,0,-1 \right\rangle$, facilitating a simultaneous measurement of the acceleration due to gravity with an asymptotic precision of $2.1\times 10^{-9}$$\Delta$g/g and the magnetic field gradient to a precision $8$pT/m. - Open Access
- 20 May 2016
- Published by Optica Publishing Group in Optics Letters
- Vol. 41 (11) , 2505-2508
Time-of-flight detection of ultra-cold atoms using resonant frequency modulation imaging
Resonant frequency modulation imaging is used to detect free falling ultra-cold atoms. A theoretical comparison of fluorescence imaging (FI) and frequency modulation imaging (FMI) is made, indicating that for low optical depth clouds, FMI accomplished a higher signal-to-noise ratio under conditions necessary for a 200 μm spatially resolved atom interferometer. A 750 ms time-of-flight measurement reveals near atom shot-noise limited number measurements of Bose-condensed atoms. The detection system is applied to high precision spinor BEC based atom interferometer.- 20 May 2016
- Published by Optica Publishing Group in Optics Letters
- Vol. 41 (11) , 2505-2508
Open AccessTime-of-flight detection of ultra-cold atoms using resonant frequency modulation imaging
Resonant frequency modulation imaging is used to detect free falling ultra-cold atoms. A theoretical comparison of fluorescence imaging (FI) and frequency modulation imaging (FMI) is made, indicating that for low optical depth clouds, FMI accomplished a higher signal-to-noise ratio under conditions necessary for a 200 μm spatially resolved atom interferometer. A 750 ms time-of-flight measurement reveals near atom shot-noise limited number measurements of Bose-condensed atoms. The detection system is applied to high precision spinor BEC based atom interferometer. - 20 February 2014
- Published by American Physical Society (APS) in Physical Review A
- Vol. 89 (2) , 023626
Role of source coherence in atom interferometery
The role of source cloud spatial coherence in a Mach-Zehnder-type atom interferometer is experimentally investigated. The visibility and contrast of a Bose-Einstein condensate (BEC) and three thermal sources with varying spatial coherence are compared as a function of interferometer time. At short times, the fringe visibility of a BEC source approaches nearly independent of pulse efficiency, while thermal sources have fringe visibilities limited to the pulse efficiency. More importantly for precision measurement systems, the BEC source maintains interference at interferometer times significantly beyond the thermal source.- 20 February 2014
- Published by American Physical Society (APS) in Physical Review A
- Vol. 89 (2) , 023626
Role of source coherence in atom interferometery
The role of source cloud spatial coherence in a Mach-Zehnder-type atom interferometer is experimentally investigated. The visibility and contrast of a Bose-Einstein condensate (BEC) and three thermal sources with varying spatial coherence are compared as a function of interferometer time. At short times, the fringe visibility of a BEC source approaches nearly independent of pulse efficiency, while thermal sources have fringe visibilities limited to the pulse efficiency. More importantly for precision measurement systems, the BEC source maintains interference at interferometer times significantly beyond the thermal source.- Open Access
The Role of Source Coherence in Atom Interferometery
The role of source cloud spatial coherence in a Mach-Zehnder type atom interferometer is experimentally investigated. The visibility and contrast of a Bose-Einstein condensate (BEC) and three thermal sources with varying spatial coherence are compared as a function of interferometer time. At short times, the fringe visibility of a BEC source approaches 100 % nearly independent of pi pulse efficiency, while thermal sources have fringe visibilities limited to the mirror efficiency. More importantly for precision measurement systems, the BEC source maintains interference at interferometer times significantly beyond the thermal source.
Open AccessThe Role of Source Coherence in Atom Interferometery
The role of source cloud spatial coherence in a Mach-Zehnder type atom interferometer is experimentally investigated. The visibility and contrast of a Bose-Einstein condensate (BEC) and three thermal sources with varying spatial coherence are compared as a function of interferometer time. At short times, the fringe visibility of a BEC source approaches 100 % nearly independent of pi pulse efficiency, while thermal sources have fringe visibilities limited to the mirror efficiency. More importantly for precision measurement systems, the BEC source maintains interference at interferometer times significantly beyond the thermal source.