Hong Chang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Hong Chang has a total of 189 co-authors. Here are the top co-authors by number of shared publications:
- Xiaotong Lu
National Time Service Center
17 shared publications Feng Guo
Chinese Academy of Sciences
13 shared publicationsXiao-Tong Lu
National Time Service Center
11 shared publicationsTing Li
Key Laboratory of Time and Frequency Primary Standards National Time Service Center Chinese Academy of Sciences 710600 Xi'an China
10 shared publicationsYebing Wang
National Time Service Center, Chinese Academy of Sciences (NTSC), Xi’an 710600, People’s Republic of China
10 shared publications- Yebing Wang
Key Laboratory of Time Reference and Applications, National Time Service Center, Chinese Academy of Sciences, Xi’ an 710600, People’s Republic of China
10 shared publications
Latest Publications
- Open Access
- 1 January 2027
- Published by Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences in Acta Physica Sinica
- Vol. 76 (4)
Active Compensation of the Narrow-Line Cooling Potential Shift in Microgravity for a Space-borne Strontium Optical Lattice Clock
空间锶原子光晶格钟由地面调试转入在轨微重力环境后,基于1S0-3P1跃迁的窄线宽冷却的俘获力和重力之间的平衡状态产生改变,在本文实验参数下窄线宽冷却原子团的平衡位置发生约为0.595 mm偏移,进而诱发光晶格束腰与窄线宽冷却原子团之间的空间失配.本文基于689 nm窄线宽冷却原子团在重力场和磁场共同作用下的动力学原理,提出利用外加均匀补偿磁场平移磁光阱磁场零点的主动位置补偿理论方案.以空间光钟镜像件物理真空腔体作为实验平台,开展了重力方向翻转的窄线宽原子冷却实验研究.磁光阱磁场梯度约为10 Gs/cm的条件下,在z轴增加122.762 µT的线性均匀补偿磁场,可将翻转状态下的窄线宽冷却原子团重新移回晶格光束腰位置,光晶格原子数恢复至翻转前的水平.实验上测量了不同补偿磁场强度下的光晶格强度,结果表明,对于空间光钟系统,补偿磁场的有效带宽为96.976(2438)µT.本研究不仅证实了基于磁场零点平移法的窄线宽冷却原子位置调控方法的可行性,而且为空间锶原子光钟在微重力条件下实现高效光晶格装载提供数据支撑.
- 1 January 2027
- Published by Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences in Acta Physica Sinica
- Vol. 76 (4)
Open AccessActive Compensation of the Narrow-Line Cooling Potential Shift in Microgravity for a Space-borne Strontium Optical Lattice Clock
空间锶原子光晶格钟由地面调试转入在轨微重力环境后,基于1S0-3P1跃迁的窄线宽冷却的俘获力和重力之间的平衡状态产生改变,在本文实验参数下窄线宽冷却原子团的平衡位置发生约为0.595 mm偏移,进而诱发光晶格束腰与窄线宽冷却原子团之间的空间失配.本文基于689 nm窄线宽冷却原子团在重力场和磁场共同作用下的动力学原理,提出利用外加均匀补偿磁场平移磁光阱磁场零点的主动位置补偿理论方案.以空间光钟镜像件物理真空腔体作为实验平台,开展了重力方向翻转的窄线宽原子冷却实验研究.磁光阱磁场梯度约为10 Gs/cm的条件下,在z轴增加122.762 µT的线性均匀补偿磁场,可将翻转状态下的窄线宽冷却原子团重新移回晶格光束腰位置,光晶格原子数恢复至翻转前的水平.实验上测量了不同补偿磁场强度下的光晶格强度,结果表明,对于空间光钟系统,补偿磁场的有效带宽为96.976(2438)µT.本研究不仅证实了基于磁场零点平移法的窄线宽冷却原子位置调控方法的可行性,而且为空间锶原子光钟在微重力条件下实现高效光晶格装载提供数据支撑.
- 1 September 2026
- Published by American Physical Society (APS) in Physical Review A
- Vol. 114 (3) , 033101
Observation of a sub-Hertz-level Bloch-Siegert shift in a Floquet-engineered optical lattice clock
When a two-level quantum system is driven periodically with a Rabi frequency $\mathrm{\ensuremath{\Omega}}$ comparable to the driving frequency ${\ensuremath{\nu}}_{s}$, the resonant transition frequency deviates from the bare energy gap---an effect known as the Bloch-Siegert shift. Observing sub-Hertz Bloch-Siegert shift is challenging due to its small energy scale and its mixing with other systematic shifts. Using a Floquet-engineered optical lattice clock, we directly observe this sub-hertz shift in ultracold atoms. We tune driving parameters to suppress micromotion and apply a self-comparison stroboscopic method to remove unwanted frequency shifts. Assisted by closed-loop feedback, we achieve high-precision results after one hour of averaging and longer integration will further improve the measurement accuracy.- 1 September 2026
- Published by American Physical Society (APS) in Physical Review A
- Vol. 114 (3) , 033101
Observation of a sub-Hertz-level Bloch-Siegert shift in a Floquet-engineered optical lattice clock
When a two-level quantum system is driven periodically with a Rabi frequency $\mathrm{\ensuremath{\Omega}}$ comparable to the driving frequency ${\ensuremath{\nu}}_{s}$, the resonant transition frequency deviates from the bare energy gap---an effect known as the Bloch-Siegert shift. Observing sub-Hertz Bloch-Siegert shift is challenging due to its small energy scale and its mixing with other systematic shifts. Using a Floquet-engineered optical lattice clock, we directly observe this sub-hertz shift in ultracold atoms. We tune driving parameters to suppress micromotion and apply a self-comparison stroboscopic method to remove unwanted frequency shifts. Assisted by closed-loop feedback, we achieve high-precision results after one hour of averaging and longer integration will further improve the measurement accuracy.- Open Access
- 25 August 2026
- Published by IOP Publishing in Chinese Physics B
Evaluation of the Dynamic Magnetic Field Induced Effects on the Lattice Loading Efficiency of a Spaceborne Sr Optical Lattice Clock
We evaluate the effects of the dynamic magnetic field on the lattice-loading efficiency of a spaceborne Sr optical lattice clock. The orbital magnetic field is calculated using the International Geomagnetic Reference Field-14 model and calibrated with in situ MAG-13 magnetometer data to include quasi-static stray fields from onboard electrical equipment. An ensemble Monte Carlo simulation is then employed to systematically investigate the dependencies of the final ensemble-averaged atomic temperature and the optical lattice loading efficiency on the laser saturation parameter $s$ and detuning $\delta$. Feedforward Helmholtz coil compensation based on the IGRF-14 calibrated field prediction restores the time-averaged efficiency from $\bar{\eta} = 5.67\%$ in the uncompensated case to $\bar{\eta} = 13.05\%$. These results quantify the influence of dynamic magnetic fields on lattice loading and provide guidance for magnetic-field compensation in future spaceborne Sr optical lattice clock missions.- 25 August 2026
- Published by IOP Publishing in Chinese Physics B
Open AccessEvaluation of the Dynamic Magnetic Field Induced Effects on the Lattice Loading Efficiency of a Spaceborne Sr Optical Lattice Clock
We evaluate the effects of the dynamic magnetic field on the lattice-loading efficiency of a spaceborne Sr optical lattice clock. The orbital magnetic field is calculated using the International Geomagnetic Reference Field-14 model and calibrated with in situ MAG-13 magnetometer data to include quasi-static stray fields from onboard electrical equipment. An ensemble Monte Carlo simulation is then employed to systematically investigate the dependencies of the final ensemble-averaged atomic temperature and the optical lattice loading efficiency on the laser saturation parameter $s$ and detuning $\delta$. Feedforward Helmholtz coil compensation based on the IGRF-14 calibrated field prediction restores the time-averaged efficiency from $\bar{\eta} = 5.67\%$ in the uncompensated case to $\bar{\eta} = 13.05\%$. These results quantify the influence of dynamic magnetic fields on lattice loading and provide guidance for magnetic-field compensation in future spaceborne Sr optical lattice clock missions. - Open Access
- 1 August 2026
- Published by IOP Publishing in Metrologia
- Vol. 63 (4) , 045010
Absolute frequency measurement of the SrII optical lattice clock at NTSC using TAI for one year
We present a measurement of the absolute frequency of the | 5 s 2 1 S 0 ⟩ → | 5 s 5 p 3 P 0 ⟩ transition in the SrII optical lattice clock at National Time Service Center, performed using a frequency link to International Atomic Time to provide traceability to the International System of Units second. Spanning one-year period with a total oprational duration of approximately 2700 hours, the measurement yields an absolute frequency to be 429 228 004 229 872.95(7) Hz, corresponding to a relative frequency uncertainty of 1.6 × 10 − 16 . This result is in good agreement with the 2025 Bureau of Weights and Measures recommended frequency and is anticipated to contribute to the future update of the CIPM recommendation frequency of the secondary frequency standards.
- 1 August 2026
- Published by IOP Publishing in Metrologia
- Vol. 63 (4) , 045010
Open AccessAbsolute frequency measurement of the SrII optical lattice clock at NTSC using TAI for one year
We present a measurement of the absolute frequency of the | 5 s 2 1 S 0 ⟩ → | 5 s 5 p 3 P 0 ⟩ transition in the SrII optical lattice clock at National Time Service Center, performed using a frequency link to International Atomic Time to provide traceability to the International System of Units second. Spanning one-year period with a total oprational duration of approximately 2700 hours, the measurement yields an absolute frequency to be 429 228 004 229 872.95(7) Hz, corresponding to a relative frequency uncertainty of 1.6 × 10 − 16 . This result is in good agreement with the 2025 Bureau of Weights and Measures recommended frequency and is anticipated to contribute to the future update of the CIPM recommendation frequency of the secondary frequency standards.
- Open Access
- 1 August 2026
- Published by AIP Publishing in AIP Advances
- Vol. 16 (8)
Dynamic control of a narrow-line red magneto-optical trap for strontium atoms under microgravity
The microgravity environment modifies the resonance condition that is formed with the participation of gravity in the 689 nm narrow-line magneto-optical trap (red MOT) of a ground-based strontium optical clock. Consequently, a cooling scheme optimized under standard 1g ground-commissioning conditions cannot be directly transferred to an in-orbit space optical clock. In this work, we establish a one-dimensional semiclassical Monte Carlo stochastic dynamics model along the ground-gravity direction to study the cooling dynamics, spatial distribution, and position compensation of a 88Sr narrow-line MOT under microgravity. The simulations show that directly applying ground-optimized parameters in microgravity leads to heating, cloud broadening, and displacement from the lattice position calibrated on the ground. Reducing the detuning can produce a smaller spatial distribution, but this behavior is mainly phase-space truncation and cannot maintain a sufficient effective atom number. We propose a dynamic-control scheme in which the laser detuning and intensity are continuously ramped, achieving an atomic temperature below 3 μK under microgravity while retaining more than 98% of the atoms in the MOT, outperforming the 1g ground-gravity reference case. On this basis, magnetic-gradient screening is used to obtain a cloud size matched to the optical-lattice mode. After an additional compensation magnetic field is introduced, the deviation between the narrow-line MOT center and the lattice position is ∼2.4 μm, far smaller than the transverse scale of the lattice beam. These results provide a physical picture and theoretical guidance for in-orbit commissioning of the narrow-line MOT in a strontium optical clock on the Chinese Space Station.
- 1 August 2026
- Published by AIP Publishing in AIP Advances
- Vol. 16 (8)
Open AccessDynamic control of a narrow-line red magneto-optical trap for strontium atoms under microgravity
The microgravity environment modifies the resonance condition that is formed with the participation of gravity in the 689 nm narrow-line magneto-optical trap (red MOT) of a ground-based strontium optical clock. Consequently, a cooling scheme optimized under standard 1g ground-commissioning conditions cannot be directly transferred to an in-orbit space optical clock. In this work, we establish a one-dimensional semiclassical Monte Carlo stochastic dynamics model along the ground-gravity direction to study the cooling dynamics, spatial distribution, and position compensation of a 88Sr narrow-line MOT under microgravity. The simulations show that directly applying ground-optimized parameters in microgravity leads to heating, cloud broadening, and displacement from the lattice position calibrated on the ground. Reducing the detuning can produce a smaller spatial distribution, but this behavior is mainly phase-space truncation and cannot maintain a sufficient effective atom number. We propose a dynamic-control scheme in which the laser detuning and intensity are continuously ramped, achieving an atomic temperature below 3 μK under microgravity while retaining more than 98% of the atoms in the MOT, outperforming the 1g ground-gravity reference case. On this basis, magnetic-gradient screening is used to obtain a cloud size matched to the optical-lattice mode. After an additional compensation magnetic field is introduced, the deviation between the narrow-line MOT center and the lattice position is ∼2.4 μm, far smaller than the transverse scale of the lattice beam. These results provide a physical picture and theoretical guidance for in-orbit commissioning of the narrow-line MOT in a strontium optical clock on the Chinese Space Station.
- Open Access
Pump-Enhanced Idler-Resonant 1626 nm Optical Parametric Oscillator
The 1626 nm laser is an essential component for conducting superlattice research on the strontium atomic clock platform. The superlattice constructed with the 1626 nm and 813 nm lasers will facilitate cutting-edge quantum information research focused on topological quantum states transport. We demonstrate an idler-resonant optical parametric oscillator that achieves 1626 nm laser output based on pump enhancement technology. Through a well-designed external cavity, a laser output of 127 mW at 1626 nm has been achieved, with a corresponding pump quantum conversion efficiency of 50% and a pump threshold of 110 mW. The long-term power stability of the output laser is ±1.5% per hour. Variations in the pump cavity modes under different experimental conditions have been measured, and the impedance matching process of the pump light within the cavity has been discussed. The 1626 nm laser and the associated technologies reported in this manuscript will provide optical support for the investigation of superlattice physics on the strontium optical lattice clock platform.
Open AccessPump-Enhanced Idler-Resonant 1626 nm Optical Parametric Oscillator
The 1626 nm laser is an essential component for conducting superlattice research on the strontium atomic clock platform. The superlattice constructed with the 1626 nm and 813 nm lasers will facilitate cutting-edge quantum information research focused on topological quantum states transport. We demonstrate an idler-resonant optical parametric oscillator that achieves 1626 nm laser output based on pump enhancement technology. Through a well-designed external cavity, a laser output of 127 mW at 1626 nm has been achieved, with a corresponding pump quantum conversion efficiency of 50% and a pump threshold of 110 mW. The long-term power stability of the output laser is ±1.5% per hour. Variations in the pump cavity modes under different experimental conditions have been measured, and the impedance matching process of the pump light within the cavity has been discussed. The 1626 nm laser and the associated technologies reported in this manuscript will provide optical support for the investigation of superlattice physics on the strontium optical lattice clock platform.
- 6 February 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (5) , 055003
Generation of a precise time scale assisted by NTSC-SrⅡ optical lattice clock
Owing to their exceptional performance characteristics, optical atomic clocks enable the generation of time scales that demonstrate superior accuracy and stability compared to conventional microwave clocks. This paper presents an experimental optical time scale based on the NTSC-SrⅡ optical lattice clock as the reference and a hydrogen maser as the flywheel oscillator. The time scale TS (SrⅡ), generated through post-processing analysis over a two-month period, achieves a peak-to-peak time variation of 0.39 ns relative to Coordinated Universal Time (UTC) and reaches a frequency stability of 1.94 × 10 −16 at 5 d. In addition, a physical optical time scale TS*(SrⅡ) was realized for approximately one month, and the peak-to-peak time difference is 0.3 ns compared to UTC. These results demonstrate that optical time scales maintain competitive performance even when the optical clock operates with limited and non-uniformly distributed uptime. This work constitutes an essential step toward a redefinition of the second of the International System of Units based on an optical transition.
- 6 February 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (5) , 055003
Generation of a precise time scale assisted by NTSC-SrⅡ optical lattice clock
Owing to their exceptional performance characteristics, optical atomic clocks enable the generation of time scales that demonstrate superior accuracy and stability compared to conventional microwave clocks. This paper presents an experimental optical time scale based on the NTSC-SrⅡ optical lattice clock as the reference and a hydrogen maser as the flywheel oscillator. The time scale TS (SrⅡ), generated through post-processing analysis over a two-month period, achieves a peak-to-peak time variation of 0.39 ns relative to Coordinated Universal Time (UTC) and reaches a frequency stability of 1.94 × 10 −16 at 5 d. In addition, a physical optical time scale TS*(SrⅡ) was realized for approximately one month, and the peak-to-peak time difference is 0.3 ns compared to UTC. These results demonstrate that optical time scales maintain competitive performance even when the optical clock operates with limited and non-uniformly distributed uptime. This work constitutes an essential step toward a redefinition of the second of the International System of Units based on an optical transition.
- 1 January 2026
- Published by Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences in Acta Physica Sinica
- Vol. 75 (4)
Research progress on precision measurement based on optical clocks
光钟作为新一代时间频率标准,通过将本地振荡器频率精准参考至光频原子跃迁频率,具备更高的频率准确度和稳定度. 自二十一世纪初第一台全光学199Hg+光钟成功问世以来,光学原子钟在近20余年里实现了跨越式发展. 当前顶尖光钟已实现10-19量级的系统不确定度和频率稳定度,这一指标较传统微波原子钟提升了两个数量级以上,为基础物理研究和精密测量领域开辟了全新研究维度. 本文系统综述了光钟的研究进展,包括中性原子光钟与离子光钟的性能突破、新型光晶格囚禁技术的应用以及系统误差抑制方法的创新;同时重点探讨了光钟在驾驭国际原子时、降低基本物理常数可能的变化速率上限、检验爱因斯坦等效性原理等精密测量领域的前沿应用,为后续光钟技术的发展与应用拓展提供参考.
- 1 January 2026
- Published by Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences in Acta Physica Sinica
- Vol. 75 (4)
Research progress on precision measurement based on optical clocks
光钟作为新一代时间频率标准,通过将本地振荡器频率精准参考至光频原子跃迁频率,具备更高的频率准确度和稳定度. 自二十一世纪初第一台全光学199Hg+光钟成功问世以来,光学原子钟在近20余年里实现了跨越式发展. 当前顶尖光钟已实现10-19量级的系统不确定度和频率稳定度,这一指标较传统微波原子钟提升了两个数量级以上,为基础物理研究和精密测量领域开辟了全新研究维度. 本文系统综述了光钟的研究进展,包括中性原子光钟与离子光钟的性能突破、新型光晶格囚禁技术的应用以及系统误差抑制方法的创新;同时重点探讨了光钟在驾驭国际原子时、降低基本物理常数可能的变化速率上限、检验爱因斯坦等效性原理等精密测量领域的前沿应用,为后续光钟技术的发展与应用拓展提供参考.
- Open Access
- 18 November 2025
- Published by Springer Nature in Communications Physics
- Vol. 8 (1)
Micromotion shift and dual modulation method in a periodic driving optical lattice clock
- 18 November 2025
- Published by Springer Nature in Communications Physics
- Vol. 8 (1)
Open AccessMicromotion shift and dual modulation method in a periodic driving optical lattice clock
- Open Access
- 17 September 2025
- Published by American Physical Society (APS) in Physical Review Research
- Vol. 7 (3)
International System of Units-traceable temperature calibration based on optical lattice clocks
We present an International System of Units (SI)-traceable temperature calibration apparatus utilizing optical lattice clocks for precision metrology. The system employs a dual-blackbody radiation shield chamber with independent temperature control, enabling synchronous differential measurements of blackbody radiation (BBR)-induced frequency shifts in atomic ensembles. By correlating these shifts with chamber temperature, we propose absolute temperature determination traceable to the SI second through the optical clock frequency. Comprehensive uncertainty analysis demonstrates an absolute temperature uncertainty below 17 mK across the 200 − 350 K range based on Sr 87 optical lattice clock, representing an improvement of two orders of magnitude over current temperature measurements based on BBR-induced Rydberg state transitions. This advancement in primary thermometry offers significant improvements in precision, reproducibility, and versatility, with potential applications in metrology, fundamental physics, and industrial processes.
- 17 September 2025
- Published by American Physical Society (APS) in Physical Review Research
- Vol. 7 (3)
Open AccessInternational System of Units-traceable temperature calibration based on optical lattice clocks
We present an International System of Units (SI)-traceable temperature calibration apparatus utilizing optical lattice clocks for precision metrology. The system employs a dual-blackbody radiation shield chamber with independent temperature control, enabling synchronous differential measurements of blackbody radiation (BBR)-induced frequency shifts in atomic ensembles. By correlating these shifts with chamber temperature, we propose absolute temperature determination traceable to the SI second through the optical clock frequency. Comprehensive uncertainty analysis demonstrates an absolute temperature uncertainty below 17 mK across the 200 − 350 K range based on Sr 87 optical lattice clock, representing an improvement of two orders of magnitude over current temperature measurements based on BBR-induced Rydberg state transitions. This advancement in primary thermometry offers significant improvements in precision, reproducibility, and versatility, with potential applications in metrology, fundamental physics, and industrial processes.