Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Charles K. Gary has a total of 44 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Compact Monitor for Ethylene and Other Plant-Produced Volatile Organic Compounds for NASA Space Missions

    by Vladimir Dobrokhotov, Alexander Larin, Elena Viugina, Adam Emberton, Andrey Livchak, Jay T. Cremer, Charles K. Gary

    In this work, we discuss the development of a compact analytical instrument for monitoring ethylene in compact greenhouses utilized by NASA to grow fresh vegetables in space. Traditionally, ethylene measurements are conducted by GC-MS systems. However, in space, they are not applicable due to their bulky size, heavy weight, special carrier gas requirement and high maintenance. Our group developed a compact and robust battery-powered ethylene monitor based on the principles of analytical gas chromatography. The device utilizes purified ambient air as a carrier gas and a metal oxide sensor as a GC detector. Implementation of a CarboWax 20 M packed column from Restek together with a Tenax TA pre-concentrator allowed us to achieve a 20 ppb limit of detection for ethylene. Full automation of measurements and reporting of concentrations was accomplished via the implementation of a Raspberry Pi 4 computer and a 7″ 720P LED capacitive touchscreen utilized for data output. Based on a feasibility study, a fully automated, industrial-grade ethylene monitoring and removal system for greenhouses was developed.


  • Open Access

    Fusion-Based Neutron Generator Production of Tc-99m and Tc-101: A Prospective Avenue to Technetium Theranostics

    by Edward J. Mausolf, Erik V. Johnstone, Natalia Mayordomo, David L. Williams, Eugene Yao Z. Guan, Charles K. Gary

    Presented are the results of 99mTc and 101Tc production via neutron irradiation of natural isotopic molybdenum (Mo) with epithermal/resonance neutrons. Neutrons were produced using a deuterium-deuterium (D-D) neutron generator with an output of 2 × 1010 n/s. The separation of Tc from an irradiated source of bulk, low-specific activity (LSA) Mo on activated carbon (AC) was demonstrated. The yields of 99mTc and 101Tc, together with their potential use in medical single-photon emission computed tomography (SPECT) procedures, have been evaluated from the perspective of commercial production, with a patient dose consisting of 740 MBq (20 mCi) of 99mTc. The number of neutron generators to meet the annual 40,000,000 world-wide procedures is estimated for each imaging modality: 99mTc versus 101Tc, D-D versus deuterium-tritium (D-T) neutron generator system outputs, and whether or not natural molybdenum or enriched targets are used for production. The financial implications for neutron generator production of these isotopes is also presented. The use of 101Tc as a diagnostic, therapeutic, and/or theranostic isotope for use in medical applications is proposed and compared to known commercial nuclear diagnostic and therapeutic isotopes.


  • Open Access

    A Fast Neutron Radiography System Using a High Yield Portable DT Neutron Source

    by David L. Williams, Craig M. Brown, David Tong, Alexander Sulyman, Charles K. Gary

    Resolution measurements were made using 14.1 MeV neutrons from a high-yield, portable DT neutron generator and a neutron camera based on a scintillation screen viewed by a digital camera. Resolution measurements were made using a custom-built, plastic, USAF-1951 resolution chart, of dimensions 125 × 98 × 25.4 mm3, and by calculating the modulation transfer function from the edge-spread function from edges of plastic and steel objects. A portable neutron generator with a yield of 3 × 109 n/s (DT) and a spot size of 1.5 mm was used to irradiate the object with neutrons for 10 min. The neutron camera, based on a 6LiF/ZnS:Cu-doped polypropylene scintillation screen and digital camera was placed at a distance of 140 cm, and produced an image with a spatial resolution of 0.35 cycles per millimeter.


  • Open Access

    Repeatable, non-destructive, spatially resolved measurements of carbon-in-soil

    by Mauricio Ayllon Unzueta, Tanay Tak, Andrew Rosenstrom, Eoin Brodie, Craig Brown, Cristina Castanha, Charles Gary, Caitlin Hicks Pries, William Larsen, Bernhard Ludewigt, et al.

    Carbon sequestration in soils represents an important opportunity to reduce the amount of greenhouse gases in the atmosphere and thereby offsetting the effects of climate change. To monitor carbon sequestration accurate measurements of soil carbon are needed that can be repeated over several growing cycles. Furthermore, soil carbon is an important indicator of soil health; accurately measuring carbon distribution is therefore important for informing land use management practices. We are developing a new instrument that images a volume of approximately 50 cm × 50 cm × 30 cm (depth) with a few centimeters resolution by applying neutron scattering techniques. Contrary to current coring methods, this approach is non-destructive, samples a large area, and allows real-time analysis of the soil carbon density. In this technique a neutron and an alpha particle are created in a deuterium-tritium fusion reaction. Due to momentum conservation the two particles move in opposite directions. Creating the particles in a small point source allows us to calculate the direction in which the neutron is moving by tracking the associated alpha particle using a position sensitive detector. The neutron can then enter the soil and inelastically scatter off atoms in the soil, creating an isotope-specific gamma ray in the process. Measuring the energy of the gamma ray allows identification of the isotope. Measuring the time-of-flight between the alpha detection and the gamma detection together with the direction of travel of the neutron allows the calculation of the 3D position of the scattering center. Using this Associate Particle Imaging (API) technique 3D density plots of carbon, oxygen, silicon, and aluminum can be obtained. In this poster we present first results from applying API to pre-mixed and standard soil samples in a laboratory setting (field tests are planned in the future). We will compare measured data to neutron-transport simulations and discuss our data analysis algorithm to reconstruct the carbon density in the soil from API data. We will further discuss achievable resolution and time requirement for measurements in the field. The information, data, or work presented herein was funded by the Advanced Research Projects Agency-Energy (ARPA-E), U.S. Department of Energy, under Contract No. DE-AC02-05CH11231.

  • High resolution x-ray microscope

    by C. K. Gary, H. Park, L. W. Lombardo, M. A. Piestrup, J. T. Cremer, R. H. Pantell, Y. I. Dudchik

    The authors present x-ray images of grid meshes and biological material obtained using a microspot x-ray tube with a multilayer optic and a 92-element parabolic compound refractive lens (CRL) made of a plastic containing only hydrogen and carbon. Images obtained using this apparatus are compared with those using an area source with a spherical lens and a spherical lens with multilayer condenser. The authors found the best image quality using the multilayer condenser with a parabolic lens, compared to images with a spherical lens and without the multilayer optics. The resolution was measured using a 155-element parabolic CRL and a multilayer condenser with the microspot tube. The experiment demonstrates about 1.1μm resolution.


  • A refractive imaging system for the characterization of x-ray sources

    by C. K. Gary, D. E. Doggett, H. Park, J. L. Harris, S. A. Pikuz, M. D. Mitchell, K. M. Chandler, T. A. Shelkovenko, D. A. Hammer

    We present a system for diagnostic imaging of x-ray sources using a compound refractive lens. Such a system can be built at a low cost, yet image at resolutions of 2 μm or better. The essential components of the system are the source to be imaged, a compound refractive lens and imaging detector (either electronic or film). In addition, spatial and spectral filters can be added to improve resolution and a laser alignment system can be used to rapidly align the source, lens and camera.


  • X-ray imaging of an X-pinch plasma with a bubble compound refractive lens

    by C. K. Gary, S. A. Pikuz, M. D. Mitchell, K. M. Chandler, T. A. Shelkovenko, D. A. Hammer, Yu. I. Dudchik

    We present diagnostic images taken of an X -pinch plasma x-ray source driven by the XP pulser (100 ns, 500 kA) at Cornell University using an x-ray bubble compound refractive lens. The lens consists of a 200 μm inside diameter glass capillary that contains about 100 biconcave microlenses formed by a string of bubbles in epoxy. A precise system for lens alignment with of 3–5 arcmin accuracy is described. X-ray images of four-wire X pinches were obtained with a spatial resolution of approximately 2 μm .


  • Optimization of the channeling radiation source crystal to produce intense quasimonochromatic x rays

    by C. K. Gary, R. H. Pantell, M. Özcan, M. A. Piestrup, D. G. Boyers

    Channeling radiation is a source of intense, tunable, quasimonochromatic x rays produced by electrons traveling along a direction of symmetry through a crystal. We analyze the effect of the channeling source crystal, through both its composition and lattice structure, on the number of photons emitted per electron, the linewidths of the radiation, and the maximum sustainable currents to identify the crystal which will yield the most photons in a bandwidth of less than 10% full width at half maximum (FWHM). Although high atomic number (Z) crystals produce a greater number of photons per electron, given their poor thermal properties these crystals cannot sustain as high average currents as lower Z crystals. The linewidths of the channeling radiation emitted from high Z crystals are as large as 50% FWHM, and electrons are dechanneled more quickly in these crystals, limiting their use as a quasimonochromatic x-ray source. Given its exceptional thermal conductivity and narrow linewidths, diamond is the optimal source crystal for the production of intense, quasimonochromatic x rays using channeling radiation.