M. A. Hopcroft
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
M. A. Hopcroft has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
B. Kim
Stanford University Department of Mechanical Engineering Stanford, California 94305 and Department of Electrical Engineering Stanford, California 94305
2 shared publications- Gaurav Bahl
Department of Mechanical Science & Engineering, University of Illinois at Urbana-Champaign, Urbana, USA
2 shared publications H. Mehta
Stanford University Department of Mechanical Engineering Stanford, California 94305 and Department of Electrical Engineering Stanford, California 94305
2 shared publicationsJ. Salvia
Stanford University Department of Mechanical Engineering Stanford, California 94305 and Department of Electrical Engineering Stanford, California 94305
2 shared publicationsM. Agarwal
Stanford University Department of Mechanical Engineering Stanford, California 94305 and Department of Electrical Engineering Stanford, California 94305
2 shared publicationsR. Melamud
Stanford University Department of Mechanical Engineering Stanford, California 94305 and Department of Electrical Engineering Stanford, California 94305
2 shared publications
Latest Publications
- 2 July 2007
- Published by AIP Publishing in Applied Physics Letters
- Vol. 91 (1) , 013505
Using the temperature dependence of resonator quality factor as a thermometer
Silicon micromechanical resonators have been designed to have a quality factor that is a strong function of temperature. This is an ideal sensor for the temperature of the resonator—it is instantaneous, consumes no power, and indicates the temperature of the resonator structure with high sensitivity. The authors present a practical implementation of an oscillator system using these resonators with a temperature resolution of better than . The signal is uniquely suited for implementing feedback control of the resonator temperature, thereby stabilizing the frequency silicon micromechanical resonators and enabling their use in high-stability frequency reference applications.- 2 July 2007
- Published by AIP Publishing in Applied Physics Letters
- Vol. 91 (1) , 013505
Using the temperature dependence of resonator quality factor as a thermometer
Silicon micromechanical resonators have been designed to have a quality factor that is a strong function of temperature. This is an ideal sensor for the temperature of the resonator—it is instantaneous, consumes no power, and indicates the temperature of the resonator structure with high sensitivity. The authors present a practical implementation of an oscillator system using these resonators with a temperature resolution of better than . The signal is uniquely suited for implementing feedback control of the resonator temperature, thereby stabilizing the frequency silicon micromechanical resonators and enabling their use in high-stability frequency reference applications.- 1 January 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 2159547X,p. 1307-1309
A High-Stability MEMS Frequency Reference
Silicon MEMS resonators with high levels of frequency stability are demonstrated in an oscillator system suitable for use as a frequency reference. The use of resonator quality factor (Q) as a temperature sensor allows us to control the temperature of the resonator with milli-degree precision, thus stabilizing the output frequency of the resonator to ~0.1 ppm. Composite Si/SiO2 resonator design has reduced the inherent frequency sensitivity of the resonator. The combination of Q(T) temperature stabilization and composite resonator design has reduced the frequency variation to ~0.01 ppm, a level that is competitive with high-performance commercial devices.
- 1 January 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 2159547X,p. 1307-1309
A High-Stability MEMS Frequency Reference
Silicon MEMS resonators with high levels of frequency stability are demonstrated in an oscillator system suitable for use as a frequency reference. The use of resonator quality factor (Q) as a temperature sensor allows us to control the temperature of the resonator with milli-degree precision, thus stabilizing the output frequency of the resonator to ~0.1 ppm. Composite Si/SiO2 resonator design has reduced the inherent frequency sensitivity of the resonator. The combination of Q(T) temperature stabilization and composite resonator design has reduced the frequency variation to ~0.01 ppm, a level that is competitive with high-performance commercial devices.