Q. Xiong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Q. Xiong has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Anton Nikiforov
Ghent University Sint-Pietersnieuwstraat 41
2 shared publications C. Leys
Department of Applied Physics, Ghent University, Jozef Plateaustraat 22, 9000 Ghent, Belgium
2 shared publicationsD. Liu
CEEE, HuaZhong University of Science and Technology, WuHan, HuBei 430074, People’s Republic of China
1 shared publicationL. Li
Department of Applied Physics, Ghent University, Jozef Plateaustraat 22, 9000 Ghent, Belgium
1 shared publicationN. Britun
Laboratoire de Chimie des Interactions Plasma-Surface (ChIPS), CIRMAP, Université de Mons 4 , 20 Place du Parc, B-7000 Mons, Belgium
1 shared publicationR. Snyders
Laboratoire de Chimie des Interactions Plasma-Surface (ChIPS), CIRMAP, Université de Mons 4 , 20 Place du Parc, B-7000 Mons, Belgium
1 shared publication
Latest Publications
- 28 October 2011
- Published by EDP Sciences in The European Physical Journal Applied Physics
- Vol. 56 (2) , 24009
LIF spectroscopy of OH radicals in a micro-flow DC discharge in Ar and He with a liquid electrode
The laser-induced fluorescence spectroscopy on a micro-flow discharge with water electrode is carried out in order to investigate OH radicals. The branches P2(6), P1(4) and P2(3) of X2Π, ν′′ = 0−A2Σ, ν′ = 1 transition are used. Laser-induced fluorescence is used in order to estimate the density of OH radicals and density of water vapor in a core of the plasma. Sputtering yield of H2O from the liquid electrode is calculated based on experimental data. It is revealed that plasma core consists of 8–10% of water in both Ar and He discharges. The density of OH radicals in the micro-flow He plasma is higher than in the glow discharge with liquid electrode and in Ar micro-flow discharge due to constriction of the positive column and different mechanism of the OH radical production.
- 28 October 2011
- Published by EDP Sciences in The European Physical Journal Applied Physics
- Vol. 56 (2) , 24009
LIF spectroscopy of OH radicals in a micro-flow DC discharge in Ar and He with a liquid electrode
The laser-induced fluorescence spectroscopy on a micro-flow discharge with water electrode is carried out in order to investigate OH radicals. The branches P2(6), P1(4) and P2(3) of X2Π, ν′′ = 0−A2Σ, ν′ = 1 transition are used. Laser-induced fluorescence is used in order to estimate the density of OH radicals and density of water vapor in a core of the plasma. Sputtering yield of H2O from the liquid electrode is calculated based on experimental data. It is revealed that plasma core consists of 8–10% of water in both Ar and He discharges. The density of OH radicals in the micro-flow He plasma is higher than in the glow discharge with liquid electrode and in Ar micro-flow discharge due to constriction of the positive column and different mechanism of the OH radical production.
- 1 October 2011
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 110 (7) , 073302
A simple profile-fitting method to determine the metastable and resonant densities in a cold atmospheric pressure argon plasma jet
A simple profile-fitting method is applied to determine the concentrations of metastable and resonant species in a cold atmospheric pressure argon plasma jet. This method is based on the analysis of the effect of self-absorption broadening on the profiles of spectral lines emitted from plasma. The Argon lines which correspond to transitions to metastable and resonant lower states were measured with high resolution optical emission spectroscopy. Fitting the measured line contours yields line-integrated densities (Nl × L) of metastable Ar(1s5) and Ar(1s3) of 1.2 × 1015 m−2 and 5.0 × 1014 m−2, respectively. For resonant species, it is difficult to perform a good density-estimation by fitting measured line contours because of the broad intrinsic resonant line shape and the low resonant densities in the plasma. Top-limits of 4.8 × 1015 m−2 and 7.2 × 1014 m−2 are estimated for resonant states Ar(1s2) and Ar(1s4), respectively. By comparing the fittings of metastable and resonant lines, it is found that the applicability of the profile-fitting routine is sensitive to the line-center optical thickness of emission lines (mainly determined by the lower states densities) and the sharpness of intrinsic line profiles of corresponding transitions.
- 1 October 2011
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 110 (7) , 073302
A simple profile-fitting method to determine the metastable and resonant densities in a cold atmospheric pressure argon plasma jet
A simple profile-fitting method is applied to determine the concentrations of metastable and resonant species in a cold atmospheric pressure argon plasma jet. This method is based on the analysis of the effect of self-absorption broadening on the profiles of spectral lines emitted from plasma. The Argon lines which correspond to transitions to metastable and resonant lower states were measured with high resolution optical emission spectroscopy. Fitting the measured line contours yields line-integrated densities (Nl × L) of metastable Ar(1s5) and Ar(1s3) of 1.2 × 1015 m−2 and 5.0 × 1014 m−2, respectively. For resonant species, it is difficult to perform a good density-estimation by fitting measured line contours because of the broad intrinsic resonant line shape and the low resonant densities in the plasma. Top-limits of 4.8 × 1015 m−2 and 7.2 × 1014 m−2 are estimated for resonant states Ar(1s2) and Ar(1s4), respectively. By comparing the fittings of metastable and resonant lines, it is found that the applicability of the profile-fitting routine is sensitive to the line-center optical thickness of emission lines (mainly determined by the lower states densities) and the sharpness of intrinsic line profiles of corresponding transitions.
- 15 March 2010
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 107 (6) , 063308
Optical and electrical diagnostics of an atmospheric pressure room-temperature plasma plume
Cold plasmas have recently received great attention. In this paper, optical and electrical diagnostics are carried out on a reliable and user-friendly plasma plume. A simple electrical model is used to simulate the electrical characteristics of the device. The plasma is represented by a resistor connected in parallel with a capacitor, an inductor, and another resistor, which are connected in series. The simulated current-voltage waveforms have very good agreement with experimental measurements. Besides, the emission spectra of the plasma are also studied. It shows that, when Ar is used as working gas, there is strong OH (hydroxyl radical) emission and the emission intensities of the emission bands are more than three times higher than that of He. On the contrary, when He is used as working gas, the emission intensities of band are much stronger. Detail analyses on these observations are presented.- 15 March 2010
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 107 (6) , 063308
Optical and electrical diagnostics of an atmospheric pressure room-temperature plasma plume
Cold plasmas have recently received great attention. In this paper, optical and electrical diagnostics are carried out on a reliable and user-friendly plasma plume. A simple electrical model is used to simulate the electrical characteristics of the device. The plasma is represented by a resistor connected in parallel with a capacitor, an inductor, and another resistor, which are connected in series. The simulated current-voltage waveforms have very good agreement with experimental measurements. Besides, the emission spectra of the plasma are also studied. It shows that, when Ar is used as working gas, there is strong OH (hydroxyl radical) emission and the emission intensities of the emission bands are more than three times higher than that of He. On the contrary, when He is used as working gas, the emission intensities of band are much stronger. Detail analyses on these observations are presented.