Robert Van Uitert
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Robert Van Uitert has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
I. Bitter
Diagnostic Radiology Department, Clinical Center, at the National Institutes of Health, Bethesda, MD 20892, USA
2 shared publicationsR. M. Summers
Member, IEEE, Diagnostic Radiology Department, Clinical Center, at the National Institutes of Health, Bethesda, MD 20892, USA
2 shared publicationsIngmar Bitter
1 shared publicationRonald M. Summers
Nat. Inst. of Health, Bethesda
1 shared publication
Latest Publications
- 30 July 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 26 (8) , 1069-1078
Automatic Correction of Level Set Based Subvoxel Precise Centerlines for Virtual Colonoscopy Using the Colon Outer Wall
Virtual colonoscopy (VC) is becoming a more prevalent method to detect and diagnose colorectal cancer. An essential component of using VC to detect cancerous polyps, especially in conjunction with computer-aided diagnosis, is the accurate calculation of the centerline of the colon. While the colon is often modeled as a simple cylinder, the amount of colonic distention may vary between patients and within the same patient often causing loops and multiple disconnected segments to be present in the colon segmentation. These variations have caused previous centerline algorithms to fail to capture a complete and accurate centerline for all colons. We have developed an automatic method to determine from a computed tomography (CT) VC a subvoxel precise centerline that is accurate even in cases of over-distended or under-distended colons. In this algorithm, the loops in the colon caused by over-distention are detected and removed when the centerline calculation is performed. Also, a newly developed method for the detection and segmentation of the outer wall of the colon is used to connect collapsed portions of the colon where the lumen segmentation fails to produce a continuous centerline. These two methods allow for a complete and accurate centerline to be calculated in uniformly distended colons as well as in colons containing segments which are over-distended and/or under-distended. We have demonstrated successfully the effectiveness of our algorithm on 50 cases, 25 of which resulted in erroneous solutions by previous centerline algorithms due to variability in the colon distention.
- 30 July 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 26 (8) , 1069-1078
Automatic Correction of Level Set Based Subvoxel Precise Centerlines for Virtual Colonoscopy Using the Colon Outer Wall
Virtual colonoscopy (VC) is becoming a more prevalent method to detect and diagnose colorectal cancer. An essential component of using VC to detect cancerous polyps, especially in conjunction with computer-aided diagnosis, is the accurate calculation of the centerline of the colon. While the colon is often modeled as a simple cylinder, the amount of colonic distention may vary between patients and within the same patient often causing loops and multiple disconnected segments to be present in the colon segmentation. These variations have caused previous centerline algorithms to fail to capture a complete and accurate centerline for all colons. We have developed an automatic method to determine from a computed tomography (CT) VC a subvoxel precise centerline that is accurate even in cases of over-distended or under-distended colons. In this algorithm, the loops in the colon caused by over-distention are detected and removed when the centerline calculation is performed. Also, a newly developed method for the detection and segmentation of the outer wall of the colon is used to connect collapsed portions of the colon where the lumen segmentation fails to produce a continuous centerline. These two methods allow for a complete and accurate centerline to be calculated in uniformly distended colons as well as in colons containing segments which are over-distended and/or under-distended. We have demonstrated successfully the effectiveness of our algorithm on 50 cases, 25 of which resulted in erroneous solutions by previous centerline algorithms due to variability in the colon distention.
- 25 January 2007
- Published by Wiley in Medical Physics
- Vol. 34 (2) , 627-638
Subvoxel precise skeletons of volumetric data based on fast marching methods
The accurate calculation of the skeleton of an object is a problem not satisfactorily solved by existing approaches. Most algorithms require a significant amount of user interaction and use a voxel grid to compute discrete and often coarse approximations of this representation of the data. We present a novel, automatic algorithm for computing subvoxel precise skeletons of volumetric data based on subvoxel precise distance fields. Most voxel based centerline and skeleton algorithms start with a binary mask and end with a list of voxels that define the centerline or skeleton. Even though subsequent smoothing may be applied, the results are inherently discrete. Our skeletonization algorithm uses as input a subvoxel precise distance field and employs a number of fast marching method propagations to extract the skeleton at subvoxel precision. We present the skeletons of various three‐dimensional (3D) data sets and digital phantom models as validations of our algorithm.
- 25 January 2007
- Published by Wiley in Medical Physics
- Vol. 34 (2) , 627-638
Subvoxel precise skeletons of volumetric data based on fast marching methods
The accurate calculation of the skeleton of an object is a problem not satisfactorily solved by existing approaches. Most algorithms require a significant amount of user interaction and use a voxel grid to compute discrete and often coarse approximations of this representation of the data. We present a novel, automatic algorithm for computing subvoxel precise skeletons of volumetric data based on subvoxel precise distance fields. Most voxel based centerline and skeleton algorithms start with a binary mask and end with a list of voxels that define the centerline or skeleton. Even though subsequent smoothing may be applied, the results are inherently discrete. Our skeletonization algorithm uses as input a subvoxel precise distance field and employs a number of fast marching method propagations to extract the skeleton at subvoxel precision. We present the skeletons of various three‐dimensional (3D) data sets and digital phantom models as validations of our algorithm.
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2006 (1557170X) , 3017-3020
Detection of Colon Wall Outer Boundary and Segmentation of the Colon Wall Based on Level Set Methods
Virtual colonoscopy (VC) has become a more prevalent and accepted method to diagnosis colorectal cancer. An essential element to detecting cancerous polyps using VC in conjunction with computer-aided detection is the accurate segmentation of the colon wall. While the inner boundary of the colon wall, the lumen-mucosal boundary, has often been the focus of previous colon segmentation work, detection of the outer wall, the serosal tissue boundary, allows for the segmentation of the colon wall, which is useful in determining both potential polyps, muscular hypertrophy and diverticulitis of the colon. Unfortunately, automatic determination of the outer colon wall position often is difficult due to the low contrast between CT attenuation values of the colon wall and the surrounding fat tissue. We have developed a level set based method to determine from a CT colonography (CTC) scan the location of the colon serosal tissue boundary. After determining this location, the algorithm segments the entire colon wall at subvoxel accurate precision. The algorithm has been validated on several CTC datasets
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2006 (1557170X) , 3017-3020
Detection of Colon Wall Outer Boundary and Segmentation of the Colon Wall Based on Level Set Methods
Virtual colonoscopy (VC) has become a more prevalent and accepted method to diagnosis colorectal cancer. An essential element to detecting cancerous polyps using VC in conjunction with computer-aided detection is the accurate segmentation of the colon wall. While the inner boundary of the colon wall, the lumen-mucosal boundary, has often been the focus of previous colon segmentation work, detection of the outer wall, the serosal tissue boundary, allows for the segmentation of the colon wall, which is useful in determining both potential polyps, muscular hypertrophy and diverticulitis of the colon. Unfortunately, automatic determination of the outer colon wall position often is difficult due to the low contrast between CT attenuation values of the colon wall and the surrounding fat tissue. We have developed a level set based method to determine from a CT colonography (CTC) scan the location of the colon serosal tissue boundary. After determining this location, the algorithm segments the entire colon wall at subvoxel accurate precision. The algorithm has been validated on several CTC datasets
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1557170X,p. 3017-3020
Detection of Colon Wall Outer Boundary and Segmentation of the Colon Wall Based on Level Set Methods
Virtual colonoscopy (VC) has become a more prevalent and accepted method to diagnosis colorectal cancer. An essential element to detecting cancerous polyps using VC in conjunction with computer-aided detection is the accurate segmentation of the colon wall. While the inner boundary of the colon wall, the lumen-mucosal boundary, has often been the focus of previous colon segmentation work, detection of the outer wall, the serosal tissue boundary, allows for the segmentation of the colon wall, which is useful in determining both potential polyps, muscular hypertrophy and diverticulitis of the colon. Unfortunately, automatic determination of the outer colon wall position often is difficult due to the low contrast between CT attenuation values of the colon wall and the surrounding fat tissue. We have developed a level set based method to determine from a CT colonography (CTC) scan the location of the colon serosal tissue boundary. After determining this location, the algorithm segments the entire colon wall at subvoxel accurate precision. The algorithm has been validated on several CTC datasets
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1557170X,p. 3017-3020
Detection of Colon Wall Outer Boundary and Segmentation of the Colon Wall Based on Level Set Methods
Virtual colonoscopy (VC) has become a more prevalent and accepted method to diagnosis colorectal cancer. An essential element to detecting cancerous polyps using VC in conjunction with computer-aided detection is the accurate segmentation of the colon wall. While the inner boundary of the colon wall, the lumen-mucosal boundary, has often been the focus of previous colon segmentation work, detection of the outer wall, the serosal tissue boundary, allows for the segmentation of the colon wall, which is useful in determining both potential polyps, muscular hypertrophy and diverticulitis of the colon. Unfortunately, automatic determination of the outer colon wall position often is difficult due to the low contrast between CT attenuation values of the colon wall and the surrounding fat tissue. We have developed a level set based method to determine from a CT colonography (CTC) scan the location of the colon serosal tissue boundary. After determining this location, the algorithm segments the entire colon wall at subvoxel accurate precision. The algorithm has been validated on several CTC datasets