  • Gamma Knife 3‐D dose distribution near the area of tissue inhomogeneities by normoxic gel dosimetry

    by Fatih Isbakan, Yekta Ülgen, Hatice Bilge, Zeynep Ozen, Onur Agus, Bora Buyuksarac

    The accuracy of the Leksell GammaPlan®, the dose planning system of the Gamma Knife Model‐B, was evaluated near tissue inhomogeneities, using the gel dosimetry method. The lack of electronic equilibrium around the small‐diameter gamma beams can cause dose calculation errors in the neighborhood of an air‐tissue interface. An experiment was designed to investigate the effects of inhomogeneity near the paranosal sinuses cavities. The homogeneous phantom was a spherical glass balloon of diameter, filled with MAGIC gel; i.e., the normoxic polymer gel. Two hollow PVC balls of radius, filled with gas, represented the air cavities inside the inhomogeneous phantom. For dose calibration purposes, gel‐containing vials were irradiated at predefined doses, and then scanned in a MR unit. Linearity was observed between the delivered dose and the reciprocal of the T2 relaxation time constant of the gel. Dose distributions are the results of a single shot of irradiation, obtained by collimating all 201 cobalt sources to a known target in the phantom. Both phantoms were irradiated at the same dose level at the same coordinates. Stereotactic frames and fiducial markers were attached to the phantoms prior to MR scanning. The dose distribution predicted by the Gamma Knife planning system was compared with that of the gel dosimetry. As expected, for the homogeneous phantom the isodose diameters measured by the gel dosimetry and the GammaPlan® differed by 5% at most. However, with the inhomogeneous phantom, the dose maps in the axial, coronal and sagittal planes were spatially different. The diameters of the 50% isodose curves differed 43% in the axis and 32% in the axis for the axial plane; by 44% in the axis and 24% in the axis for the coronal plane; and by 32% in the axis and 42% in the axis for the sagittal plane. The lack of ability of the GammaPlan® to predict the rapid dose fall off, due to the air cavities behind or near the lesion led to an overestimation of the dose that was actually delivered. Clinically, this can result in underdosing of lesions near tissue inhomogeneities in patients under treatment.


  • Relative Dose Distribution In Gamma Knife Treatment Near Tissue Inhomogeneties

    by F. Isbakan, B. Buyuksarac, O. Agus, Y. Ulgen, H. Bilge, Z. Ozen

    The primary goal in this study was to investigate 3-D dose distribution, near the areas of tissue inhomogeneities, in Gamma Knife radiosurgery with the gel dosimetry. The spherical glass balloon of a diameter of 16 cm filled with the gel forms the homogeneous phantom; and an identical balloon with two corks placed on each side to represent the air cavities forms the inhomogeneous phantom. Dose calibration is performed by irradiating vials at known doses and then utilizing the R2-dose calibration curve. Stereotactic frames and fudicial markers were attached to the phantoms for MR scanning and image processing. Dose distributions from a single shot, using all 201 Cobalt sources, delivered to a known point with identical coordinates, are calculated both in homogeneous and inhomogeneous gel phantoms. In the aspect of dosimetrical quality control, the Gamma Knife planning system predicted dose distribution is compared with the experimental results. In the homogeneous phantom, the gel dosimetry calculated dose distribution is in good agreement with the GammaPlan predicted dose distribution. However, with the inhomogeneous phantom, the dose distribution is spatially different and significant differences in dose levels are observed