CKChristine Keul

Christine Keul

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Christine Keul has a total of 26 co-authors. Here are the top co-authors by number of shared publications:

  • Jan-Frederik Güth

    Department of Prosthetic Dentistry, Center for Dentistry and Oral Medicine (Carolinum), Goethe-University Frankfurt Am Main, Frankfurt, Germany

    7 shared publications
  • Bogna Stawarczyk

    Department of Prosthetic Dentistry, University Hospital, LMU Munich, 80336 Munich, Germany

    3 shared publications
  • Cornelius Runkel

    2 shared publications
  • Daniel Edelhoff

    Director and Chair, Department of Prosthetic Dentistry, University Hospital, Ludwig Maximilian University of Munich, Munich, Germany

    2 shared publications
  • Jan-Frederik Guth

    Goethe Univ, Ctr Dent & Oral Med Carolinum, Dept Prosthet Dent, Frankfurt, Germany

    2 shared publications
  • Kurt Erdelt

    Research Engineer, Department of Prosthetic Dentistry, University Hospital, Ludwig Maximilian University of Munich, Munich, Germany

    2 shared publications

Latest Publications

  • Open Access

    Accuracy of full-arch digitalization for partially edentulous jaws — a laboratory study on basis of coordinate-based data analysis

    by Panagiotis Kontis, Jan-Frederik Güth, Christine Keul

    Objectives: To compare the accuracy (trueness and precision) of direct digitization of four different dental gap situation with two IOS (intraoral scanner). Materials and methods: Four partially edentulous polyurethane mandible models were used: (1) A (46, 45, 44 missing), (2) B (45, 44, 34, 35 missing), (3) C (42, 41, 31, 32 missing), and (4) D (full dentition). On each model, the same reference object was fixed between the second molars of both quadrants. A dataset (REF) of the reference object was generated by a coordinate measuring machine. Each model situation was scanned by (1) OMN (Cerec AC Omnicam) and (2) PRI (Cerec Primescan AC) (n = 30). Datasets of all 8 test groups (N = 240) were analyzed using inspection software to determine the linear aberrations in the X-, Y-, Z-axes and angular deviations. Mann–Whitney U and two-sample Kolmogorov–Smirnov tests were used to detect differences for trueness and precision. Results: PRI revealed higher trueness and precision in most of the measured parameters ( $${\overrightarrow{V}}_{E}$$ V → E 120.95 to 175.01 μm, $$\overrightarrow{V}_{E}$$ V → E (x) − 58.50 to − 9.40 μm, $$\overrightarrow{V}_{E}$$ V → E (z) − 70.35 to 63.50 μm), while OMN showed higher trueness for $$\overrightarrow{V}_{E}$$ V → E (y) regardless of model situation (− 104.90 to 34.55 μm). Model D revealed the highest trueness and precision in most of the measured parameters regardless of IOS ( $$\overrightarrow{V}_{E}$$ V → E 120.95 to 195.74 μm, $$\overrightarrow{V}_{E}$$ V → E (x) − 9.40 to 66.75 μm, $$\overrightarrow{V}_{E}$$ V → E (y) − 14.55 to 51.50 μm, $$\overrightarrow{V}_{E}$$ V → E (z) 63.50 to 120.75 μm). Conclusions: PRI demonstrated higher accuracy in the X- and Z-axes, while OMN depicted higher trueness in the Y-axis. For PRI, Model A revealed the highest distortion, while for OMN, Model B produced the largest aberrations in most parameters. Clinical relevance Current results suggest that both investigated IOS are sufficiently accurate for the manufacturing of tooth-borne restorations and orthodontic appliances. However, both hardware specifications of IOS and the presence of edentulous gaps in the dental model have an influence on the accuracy of the virtual model dataset.


    • 1 January 2022
      • Vol. 25  (1) , 17-25

    Influence of intraoral conditions on the accuracy of full-arch scans by Cerec Primescan AC: an in vitro and in vivo comparison

    by Christine Keul, Jan-Frederik Guth

    Aim: To determine the effect of intraoral conditions on the accuracy of digital full-arch scans. Materials and methods: A reference bar was used for the in vivo and in vitro parts of the present study. For the in vitro part (PAT-vitro), the bar was fixed to connect the maxillary second molars on the patient's resin model. The same reference bar was fixed in a similar position intraorally for the in vivo testing (PAT-vivo). Model and patient were digitized using an intraoral scanner (Cerec Primescan AC, N = 40, n [PAT-vitro] = 20, n [PAT-vivo] = 20). Datasets were exported and metrically analyzed (Geomagic Control 2015) to determine the 3D linear and angular distortions in all three coordinate axes of the datasets with reference to the bar. Normality of the data distribution was tested using the Kolmogorov-Smirnov and Shapiro-Wilk tests. Homogeneity of the variances was tested using the Levene test. Statistically significant differences for all measured parameters in view of trueness were determined using the two-sample t test, and in view of precision using the two-sample Kolmogorov-Smirnov test. Results: The PAT-vivo group showed significantly higher trueness for most of the measured linear and angular distortion parameters than the PAT-vitro group. Regarding precision, the PAT-vitro group showed significantly better values for most of the measured linear and angular distortion parameters than the PAT-vivo group. Conclusions: Within the limitations of the present study, Cerec Primescan AC leads to comparable accuracy parameters when applied in vivo and in vitro. The reproducibility (precision) was higher when scans were performed in vitro. Due to the high trueness, the system seems to be a valid tool to obtain digital full-arch datasets in vivo with comparable accuracy to in vitro tests.


  • Influence of speed sintering on the fit and fracture strength of 3-unit monolithic zirconia fixed partial dentures

    by Ana Elisa Kauling, Jan-Frederik Güth, Kurt Erdelt, Daniel Edelhoff, Christine Keul


    • 1 June 2020
      • Vol. 23  (2) , 129-138

    Accuracy of data obtained from impression scans and cast scans using different impression materials

    by Christine Keul, Cornelius Runkel, Jan-Frederik Guth, Oliver Schubert

    Aim: Despite the expanding implementation of intraoral scanning (IOS) devices, indirect digitization of conventional impressions or casts still represents the primary access to CAD/CAM. The aim of this study was to evaluate the accuracy of data acquired from impression scans and cast scans with respect to impression material and type of cast used. Materials and methods: A standardized titanium model for a four-unit fixed dental prosthesis (FDP) served as a testing model. Industrial computed tomography (CT) was applied, generating a reference data set. Four different impression materials were utilized (n = 12 per material): 1) Impregum Penta (polyether/group PE); 2) Imprint 4 Penta Super Quick Heavy + Super Quick Light (polyvinyl siloxane (PVS)/group PVS-I); 3) Dimension Penta H Quick + L (PVS/group PVS-D); and 4) Imprint 4 Preliminary Penta Super Quick (PVS/group PVS-P). Data were obtained from three different model situations, ie, impressions (group IMP), unsectioned plaster casts (group UNSEC), and sectioned casts (group SEC). The surfaces were digitized three times each using a laboratory scanner. The resulting test data were superposed with the reference data using a best-fit algorithm to evaluate accuracy. Statistical analysis was conducted using the Kolmogorov-Smirnov, Kruskal-Wallis, and Mann-Whitney tests (level of significance: P < 0.050). Results: Imprint 4 Penta presented the highest overall accuracy, while Imprint 4 Preliminary Penta Super Quick displayed the poorest results. Regarding the model situation (impression scan vs cast scan), impression scans from Impregum Penta and Imprint 4 Penta showed superior results. Conclusion: Impression scans in combination with high-precision impression material results in the most accurate data.


  • Impact of fabrication procedures on residual monomer elution of conventional polymethyl methacrylate (PMMA)—a measurement approach by UV/Vis spectrophotometry

    by Christine Keul, Judith Seidl, Jan-Frederik Güth, Anja Liebermann

    Objectives To analyse the residual monomer (MMA) elution of polymethyl methacrylate (PMMA) in distilled water after diverse fabrication methods and aging procedures. Materials and methods PMMA specimens (N = 192, PalaXpress; Kulzer, Hanau, Germany) were manufactured (pouring, n = 96/injection, n = 96) and polymerized in water (55°C) without pressure (n = 48) and with 2 bar pressure (n = 48). Specimens were grinded (n = 24) or polished (n = 24) and aged for 12 h in distilled water/37°C (n = 12) or at air/20°C (n = 12) and stored afterwards in distilled water at 37°C. MMA elution was evaluated after 1, 2, 3, 4, 5, 6, 7, 10, 15 days (UV/Vis spectrophotometry). Data were analysed with Kolmogorov-Smirnov, Mann-Whitney-U and Cohen-d test using SPSS (α < 0.5). Results The pouring procedure resulted in significantly higher MMA elution than the injection procedure up to 5 days. Polymerization with a pressure of 2 bar reduced the MMA elution significantly for poured specimens. Polishing reduced the MMA elution in comparison to grinding. Conclusions The fabrication procedure (pouring/injection) showed the strongest correlation to the MMA elution (r = 0.500), followed by polishing (r = 0.243), the pressure during polymerization (r = 0.109) and the storage medium (r = 0.053). Clinical relevance Higher MMA elution may increase the risk of chemical irritations, allergic reactions and hypersensitivities of the oral mucosa. Technicians and dentists should be aware about the elution differences dependent on the fabrication procedure.


  • Open Access

    In vivo wear of CAD-CAM composite versus lithium disilicate full coverage first-molar restorations: a pilot study over 2 years

    by Jan-Frederik Güth, Kurt Erdelt, Christine Keul, Gintare Burian, Josef Schweiger, Daniel Edelhoff

    Objectives: To present a digital approach to measure and compare material wear behavior of antagonistic first molar restorations made of an experimental CAD/CAM composite (COMP) and lithium disilicate ceramic (LS2) in patients with reconstructed vertical dimension of occlusion (VDO) after generalized hard tissue loss.Methods: A total of 12 patients underwent complete full jaw rehabilitation with full occlusal coverage restorations made either of COMP or LS2. The first molar restorations (n = 48) were chosen for wear examination. At annual recall appointments, polyether impressions were taken, and resulting plaster casts were digitalized using a laboratory scanner. Mean observation period was 371 days for first and 769 days for second year. The resulting 96 datasets were analyzed by superimposition of 3-D datasets using an iterative best-fit method. Based on the superimposition data, the wear rates of the occlusal contact areas (OCAs) were calculated.Results: For antagonistic restorations made of COMP, the average wear rate was 24.8 ± 13.3 μm/month, while for LS2, it was 9.5 ± 4.3 μm/month in first year, with significant differences (p < 0.0001) between the materials. In second year, monthly wear rates decreased significantly for both materials: COMP (16.2 ± 10.7 μm/month) and LS2 (5.5 ± 3.3 μm/month). Statistical comparison between wear time showed significant differences for both materials: COMPp < 0.037 and LS2p < 0.001. A logarithmic fit (COMPR2 = 0.081; LS2R2 = 0.038) of the data was calculated to estimate the wear progression.Significance: In patients with reconstructed VDO, restorations made of LS2 show a more stable wear behavior than ones out of experimental CAD/CAM composite. In cases of complete rehabilitation, load bearing CAD/CAM-composite restorations should be critically considered for application due to their occlusal wear behavior. However, when choosing a restorative material, not only the functional occlusal stability should be taken into account but also the prospect of minimally invasive treatment with maximum preservation of natural tooth structures.


  • Digital impressions in dentistry—accuracy of impression digitalisation by desktop scanners

    by Cornelius Runkel, Jan-Frederik Güth, Kurt Erdelt, Christine Keul

    Objectives To test if the partially digital workflow by digitalisation of the impression reveals a comparable accuracy as the indirect digitalisation of the gypsum cast for 4-unit fixed dental prostheses (FDPs). Materials and methods A titanium model with a tapered full veneer preparation of a molar and premolar was used as analysis model. To receive a virtual three-dimensional reference dataset (REF), it was digitised by industrial computed tomography. Three impression materials were used with individual impression trays (N = 36, n/material = 12): (1) PE (Impregum Penta), (2) PVS-I (Imprint 4 Penta: Super Quick Heavy plus Super Quick Light), and (3) PVS-D (Dimension Penta: H Quick plus L). For partially digital workflow (group IMP), two desktop scanners were used: (1) D810 (3Shape D810) and (2) ZZ (Zirkonzahn S600ARTI). For indirect digitalisation (group CAST), gypsum master casts were manufactured and digitalised using the same desktop scanners. Virtual datasets were superimposed by best fit algorithm, and accuracy was analysed by calculating the Euclidean distances (ED) to the REF (Geomagic Qualify). Statistic was determined (Kruskal-Wallis H test, Mann-Whitney U post hoc analysis, two-sample Kolmogorov-Smirnov test, p < 0.05). Results ZZ showed for positive deviations superior accuracy for IMP than for CAST. PE and PVS-I showed superior accuracy than PVS-D. D810 showed partially significant better performance with PVS-I and PVS-D than ZZ. Conclusions The partially digital workflow by digitalisation of the impression can be used for clinical indications of small-span fixed dental prostheses. However, for this indication, the impression material and the desktop scanner are more decisive for the accuracy of virtual model datasets. Clinical relevance Despite the rapid advancement of the computer-aided technology for dental therapy purposes, the implementation of this technique is not as fast as the technical development. In order to combine the well-established procedure to use elastomeric materials for a conventional impression and to avoid the drawbacks of casting it by gypsum, the digitalisation of the impression itself by a desktop scanner may be a logical procedure as an access point to the digital workflow. However, there is only limited information about the accuracy of this partially digital workflow by the digitalisation of modern impression materials in comparison to the well-known process of indirect digitalisation of gypsum casts.


  • Top Cited Papers

    Accuracy of full-arch digital impressions: an in vitro and in vivo comparison

    by Christine Keul, Jan-Frederik Güth

    Comparison of full-arch digital impressions to conventional impressions in vitro and in vivo.


  • Einfluss der Scanstrategie auf die Genauigkeit digitaler Ganzkieferabformungen

    by Christine Keul, Jan-Frederik Güth

    Zusammenfassung: Bei der digitalen intraoralen Abformung stellt sich die Frage nach der optimalen Scanstrategie zur Erzeugung eines genauen virtuellen Abbildes der klinischen Situation. Während bei der indirekten Digitalisierung im zahntechnischen Labor der Digitalisierungsablauf fest durch die Software des Scansystems vorgegeben ist, entscheidet bei der direkten Digitalisierung trotz Herstellerempfehlungen der Behandler am Behandlungsstuhl selbst über den Scanpfad. Während manche Behandler lieber lineare Scanbewegungen durchführen, bevorzugen andere beispielsweise eher s-förmige Bewegungen. Doch haben diese unterschiedlichen Scanbewegungen einen relevanten Einfluss auf das Scanergebnis?