Allan J. Dunlop
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Allan J. Dunlop has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
Duncan W.S. Stephen
Department of Clinical Biochemistry, 1st Floor, Link Building, Aberdeen Royal Infirmary, Foresterhill, Aberdeen, AB25 2ZD, UK
1 shared publicationIain Clunie
Department of Clinical Biochemistry, 1st Floor, Link Building, Aberdeen Royal Infirmary, Foresterhill, Aberdeen, AB25 2ZD, UK
1 shared publicationJames J. Allison
Department of Clinical Biochemistry, 1st Floor, Link Building, Aberdeen Royal Infirmary, Foresterhill, Aberdeen, AB25 2ZD, UK
1 shared publication
Latest Publications
- Open Access
- 1 April 2013
- Published by Oxford University Press (OUP) in Journal of Chromatographic Science
- Vol. 52 (4) , 351-356
Determination of Cotinine by LC-MS-MS with Automated Solid-Phase Extraction
Cotinine is the primary metabolite of nicotine and the preferred biomarker for assessing cigarette smoke exposure. Several liquid chromatography–tandem mass spectrometry (LC–MS-MS) methods have been described for measuring cotinine in biological fluids. Sample preparation typically involves manual solvent evaporation and reconstitution steps. This study describes a novel LC–MS-MS method for the quantification of cotinine by using electrospray ionization with multiple reaction monitoring and cotinine-d3 as internal standard, coupled with an automated solid-phase extraction (SPE) procedure. The assay was linear over the analytical range of 0.5–1,000 ng/mL. The limits of detection and quantification were 0.13 and 0.20 ng/mL, respectively. Intra-assay and inter-assay imprecision of cotinine in all samples was <5 and 95–100%. Matrix effects in serum and plasma were 500 samples).
- 1 April 2013
- Published by Oxford University Press (OUP) in Journal of Chromatographic Science
- Vol. 52 (4) , 351-356
Open AccessDetermination of Cotinine by LC-MS-MS with Automated Solid-Phase Extraction
Cotinine is the primary metabolite of nicotine and the preferred biomarker for assessing cigarette smoke exposure. Several liquid chromatography–tandem mass spectrometry (LC–MS-MS) methods have been described for measuring cotinine in biological fluids. Sample preparation typically involves manual solvent evaporation and reconstitution steps. This study describes a novel LC–MS-MS method for the quantification of cotinine by using electrospray ionization with multiple reaction monitoring and cotinine-d3 as internal standard, coupled with an automated solid-phase extraction (SPE) procedure. The assay was linear over the analytical range of 0.5–1,000 ng/mL. The limits of detection and quantification were 0.13 and 0.20 ng/mL, respectively. Intra-assay and inter-assay imprecision of cotinine in all samples was <5 and 95–100%. Matrix effects in serum and plasma were 500 samples).