Nancy Goodyear
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Nancy Goodyear has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Daniel Warden
Department of Biological Sciences, University of Massachusetts Lowell, Lowell, MA; Medical Student, University of Massachusetts Medical School, Worcester, MA
1 shared publicationE. M. Dogan‐Guner
Chemical Engineering Department University of Massachusetts Lowell Lowell MAUSA
1 shared publicationH. Mohamed
Department of Biomedical and Nutritional Sciences University of Massachusetts Lowell Lowell MA USA
1 shared publicationJason Marshall
Toxics Use Reduction Institute, University of Massachusetts Lowell, Lowell, MA, USA
1 shared publication- Jason Marshall
Toxics Use Reduction Institute, University of Massachusetts Lowell, Lowell, MA
1 shared publication Jennifer M. Nicoloro
Department of Biomedical and Nutritional Sciences, University of Massachusetts Lowell, Lowell, MA, USA
1 shared publication
Latest Publications
- 5 May 2020
- Published by Elsevier in Journal of Microbiological Methods
- Vol. 173, 105937
A novel comprehensive efficacy test for textiles intended for use in the healthcare setting
- 5 May 2020
- Published by Elsevier in Journal of Microbiological Methods
- Vol. 173, 105937
A novel comprehensive efficacy test for textiles intended for use in the healthcare setting
- 16 December 2018
- Published by Oxford University Press (OUP) in Journal of Applied Microbiology
- Vol. 126 (3) , 965-972
Stabilization and Controlled Release of Microencasulated Hydrogen Peroxide for Wound Treatment Applications
Aims Hydrogen peroxide (H2O2) disinfection applications are limited by its rapid inactivation. The aims of this study were to 1) microencapsulate H2O2 in silica hydrogels to obtain controlled release up to 72 hours, 2) test hydrogel antimicrobial activity against four common pathogens, and 3) assess H2O2 release kinetics and antimicrobial activity in 35 – 65% relative humidity and 37°C to approximate bandaged wound conditions. Methods and Results Hydrogels were characterized using scanning electron microscopy, nitrogen sorption porosimetry, Brunauer Emmet Teller analysis, and the Barret – Joyner – Halenda method. Hydrogels formed at lower pH demonstrated increased surface area and decreased pore size, resulting in H2O2 release lasting 72 hours. Using agar well diffusion for antimicrobial activity, statistically significant zones of inhibition (as compared to controls) were seen for Escherichia coli, Staphylococcus aureus, Pseudomona aeruginiosa, and Vancomycin‐resistant Enterococcus faecalis. Activity remained for hydrogels aged for 72 hours in humid, 37°C conditions. Conclusions Hydrogels can be synthesized to provide a continuous, controlled release of H2O2 for up to 72 hours. Significance and Impact of the Study Stable, controlled‐release H2O2 hydrogels have potential applications for wound treatment and disinfection of medical equipment, through bonding to bandages or materials such as catheter lumens.
- 16 December 2018
- Published by Oxford University Press (OUP) in Journal of Applied Microbiology
- Vol. 126 (3) , 965-972
Stabilization and Controlled Release of Microencasulated Hydrogen Peroxide for Wound Treatment Applications
Aims Hydrogen peroxide (H2O2) disinfection applications are limited by its rapid inactivation. The aims of this study were to 1) microencapsulate H2O2 in silica hydrogels to obtain controlled release up to 72 hours, 2) test hydrogel antimicrobial activity against four common pathogens, and 3) assess H2O2 release kinetics and antimicrobial activity in 35 – 65% relative humidity and 37°C to approximate bandaged wound conditions. Methods and Results Hydrogels were characterized using scanning electron microscopy, nitrogen sorption porosimetry, Brunauer Emmet Teller analysis, and the Barret – Joyner – Halenda method. Hydrogels formed at lower pH demonstrated increased surface area and decreased pore size, resulting in H2O2 release lasting 72 hours. Using agar well diffusion for antimicrobial activity, statistically significant zones of inhibition (as compared to controls) were seen for Escherichia coli, Staphylococcus aureus, Pseudomona aeruginiosa, and Vancomycin‐resistant Enterococcus faecalis. Activity remained for hydrogels aged for 72 hours in humid, 37°C conditions. Conclusions Hydrogels can be synthesized to provide a continuous, controlled release of H2O2 for up to 72 hours. Significance and Impact of the Study Stable, controlled‐release H2O2 hydrogels have potential applications for wound treatment and disinfection of medical equipment, through bonding to bandages or materials such as catheter lumens.
- 24 September 2015
- Published by Oxford University Press (OUP) in Journal of Applied Microbiology
- Vol. 119 (5) , 1245-1252
The effectiveness of three home products in cleaning and disinfection of Staphylococcus aureus and Escherichia coli on home environmental surfaces
The objectives of this study were to investigate three products for: (i) cleaning effectiveness on two common household surfaces, and (ii) disinfection effectiveness against two common bacteria. Products included conventional ('bleach'), environmentally preferable (EP), do-it-yourself (DIY: distilled white vinegar, club soda, tea tree oil), 24-h old DIY, and individual DIY components in dilution. For cleaning ceramic, no product was effective (≥85% removal of Hucker's soil), however, DIY performed better than EP and bleach. On stainless, only DIY failed to meet the standard. For disinfection, bleach and EP achieved ≥5·00 log10 reductions under all conditions. DIY and components were more active against Escherichia coli than Staphylococcus aureus but only fresh DIY and 50% vinegar achieved ≥5·00 log10 reductions. EP is an effective alternative to bleach. DIY may be an adequate alternative for cleaning ceramic and for household use, where complete elimination of micro-organisms is unnecessary; however, it must be freshly prepared each day. This is the first report of performance of purportedly safer alternatives for both cleaning and disinfection for use in home health care. The EP product and DIY are potential alternatives for some household uses.
- 24 September 2015
- Published by Oxford University Press (OUP) in Journal of Applied Microbiology
- Vol. 119 (5) , 1245-1252
The effectiveness of three home products in cleaning and disinfection of Staphylococcus aureus and Escherichia coli on home environmental surfaces
The objectives of this study were to investigate three products for: (i) cleaning effectiveness on two common household surfaces, and (ii) disinfection effectiveness against two common bacteria. Products included conventional ('bleach'), environmentally preferable (EP), do-it-yourself (DIY: distilled white vinegar, club soda, tea tree oil), 24-h old DIY, and individual DIY components in dilution. For cleaning ceramic, no product was effective (≥85% removal of Hucker's soil), however, DIY performed better than EP and bleach. On stainless, only DIY failed to meet the standard. For disinfection, bleach and EP achieved ≥5·00 log10 reductions under all conditions. DIY and components were more active against Escherichia coli than Staphylococcus aureus but only fresh DIY and 50% vinegar achieved ≥5·00 log10 reductions. EP is an effective alternative to bleach. DIY may be an adequate alternative for cleaning ceramic and for household use, where complete elimination of micro-organisms is unnecessary; however, it must be freshly prepared each day. This is the first report of performance of purportedly safer alternatives for both cleaning and disinfection for use in home health care. The EP product and DIY are potential alternatives for some household uses.
- 1 April 2014
- Published by Elsevier in American Journal of Infection Control
- Vol. 42 (4) , 462-463
Fabric softeners impact cleaning, but not disinfection, by a saturated steam vapor system
- 1 April 2014
- Published by Elsevier in American Journal of Infection Control
- Vol. 42 (4) , 462-463
Fabric softeners impact cleaning, but not disinfection, by a saturated steam vapor system
- 16 December 2013
- Published by Oxford University Press (OUP) in Letters in Applied Microbiology
- Vol. 58 (4) , 370-375
Variation in detection limits between bacterial growth phases and precision of an ATP bioluminescence system
To determine the detection limits of the SystemSure Plus, Escherichia coli and Staphylococcus aureus growth curve samples were taken in lag (1 h), log (6 h), stationary (12 h) and death phases (E. coli 144 h, Staph. aureus 72 h). At each time point, the log10 CFU ml(-1) was determined for the dilution where the SystemSure read 0 relative light units (RLU). Average detection limits were E. coli: lag 6·27, log 5·88, stationary 7·45 and death 6·88; Staph. aureus: lag 4·37, log 5·15, stationary 7·88 and death 7·57. Between-run precision was determined with positive control; within-run precision with positive control, lag and log growth for each bacteria. Within-run precision mean RLU (CV): positive control 274 (12%), E. coli lag 1 (63%), log 2173 RLU (19%), Staph. aureus lag 2 (58%) and log 5535 (18%). Between-run precision was 232 (16%). The precision is adequate with most values within the 95% confidence interval. The detection limit varied by 3·51 log10 for Staph. aureus and 1·47 log10 for E. coli. The lowest detection limits were during E. coli log and Staph. aureus lag phases; the highest was during stationary phase. These results suggest that organism identification and growth phase both impact ATP RLU readings. Surface hygiene is a critical component of food safety and infection control; increasingly, ATP detection by bioluminescence is used to evaluate surface hygiene and effective cleaning. This is the first study to show that the number of living and potentially infectious bacteria remaining when the device reads zero varies between the different bacterial life cycle phases: lag, log, stationary and death. ATP device users need to be aware of this information to use the devices appropriately.
- 16 December 2013
- Published by Oxford University Press (OUP) in Letters in Applied Microbiology
- Vol. 58 (4) , 370-375
Variation in detection limits between bacterial growth phases and precision of an ATP bioluminescence system
To determine the detection limits of the SystemSure Plus, Escherichia coli and Staphylococcus aureus growth curve samples were taken in lag (1 h), log (6 h), stationary (12 h) and death phases (E. coli 144 h, Staph. aureus 72 h). At each time point, the log10 CFU ml(-1) was determined for the dilution where the SystemSure read 0 relative light units (RLU). Average detection limits were E. coli: lag 6·27, log 5·88, stationary 7·45 and death 6·88; Staph. aureus: lag 4·37, log 5·15, stationary 7·88 and death 7·57. Between-run precision was determined with positive control; within-run precision with positive control, lag and log growth for each bacteria. Within-run precision mean RLU (CV): positive control 274 (12%), E. coli lag 1 (63%), log 2173 RLU (19%), Staph. aureus lag 2 (58%) and log 5535 (18%). Between-run precision was 232 (16%). The precision is adequate with most values within the 95% confidence interval. The detection limit varied by 3·51 log10 for Staph. aureus and 1·47 log10 for E. coli. The lowest detection limits were during E. coli log and Staph. aureus lag phases; the highest was during stationary phase. These results suggest that organism identification and growth phase both impact ATP RLU readings. Surface hygiene is a critical component of food safety and infection control; increasingly, ATP detection by bioluminescence is used to evaluate surface hygiene and effective cleaning. This is the first study to show that the number of living and potentially infectious bacteria remaining when the device reads zero varies between the different bacterial life cycle phases: lag, log, stationary and death. ATP device users need to be aware of this information to use the devices appropriately.
- 1 October 2012
- Published by American Society for Clinical Laboratory Science in American Society for Clinical Laboratory Science
- Vol. 25 (4) , 219-223
Effectiveness of Five-day-old 10% Bleach in a Student Microbiology Laboratory Setting
In the student laboratory, 10% bleach (sodium hypochlorite) is used to disinfect benches before and after work, and when a spill occurs. Centers for Disease Control and Prevention (CDC) Guidelines recommend diluting bleach daily. In a student laboratory setting, the organisms in use are known and may include only selected standard bacteria. Diluting bleach daily is time consuming and wastes bleach. We hypothesized that 10% bleach stored in low density polyethylene (LDPE) wash bottles would maintain sufficient chlorine concentration to be effective against the organisms used in the student laboratory for five days, so that bleach could be diluted weekly instead of daily. Approximately 3 x 106 CFU of each bacterium were spotted to a laboratory bench surface in duplicate and allowed to air dry. One spot was individually cleaned with five-day old 10% bleach following the same protocol as student laboratories. The second spot was uncleaned and sampled as a control. Contact plates containing D/E Neutralizing agar were touched to the spots, incubated overnight at 35°C and examined for growth. An uninoculated spot was also sampled as a background control. A total of 22 different organisms were tested, representing the major groups of organisms used in the student laboratories. All organisms tested were eliminated by the five-day old bleach. All uncleaned spots showed dense growth. The background control had no growth. Reducing the dilution of bleach to once a week rather than daily will save time and money, which can then be devoted to more teaching and curriculum responsibilities, while still maintaining laboratory safety. ABBREVIATIONS LDPE-low density polyethylene, CDC-Centers for Disease Control and Prevention, CFU-colony forming units, TSA-tryptic soy agar, TSB-tryptic soy broth
- 1 October 2012
- Published by American Society for Clinical Laboratory Science in American Society for Clinical Laboratory Science
- Vol. 25 (4) , 219-223
Effectiveness of Five-day-old 10% Bleach in a Student Microbiology Laboratory Setting
In the student laboratory, 10% bleach (sodium hypochlorite) is used to disinfect benches before and after work, and when a spill occurs. Centers for Disease Control and Prevention (CDC) Guidelines recommend diluting bleach daily. In a student laboratory setting, the organisms in use are known and may include only selected standard bacteria. Diluting bleach daily is time consuming and wastes bleach. We hypothesized that 10% bleach stored in low density polyethylene (LDPE) wash bottles would maintain sufficient chlorine concentration to be effective against the organisms used in the student laboratory for five days, so that bleach could be diluted weekly instead of daily. Approximately 3 x 106 CFU of each bacterium were spotted to a laboratory bench surface in duplicate and allowed to air dry. One spot was individually cleaned with five-day old 10% bleach following the same protocol as student laboratories. The second spot was uncleaned and sampled as a control. Contact plates containing D/E Neutralizing agar were touched to the spots, incubated overnight at 35°C and examined for growth. An uninoculated spot was also sampled as a background control. A total of 22 different organisms were tested, representing the major groups of organisms used in the student laboratories. All organisms tested were eliminated by the five-day old bleach. All uncleaned spots showed dense growth. The background control had no growth. Reducing the dilution of bleach to once a week rather than daily will save time and money, which can then be devoted to more teaching and curriculum responsibilities, while still maintaining laboratory safety. ABBREVIATIONS LDPE-low density polyethylene, CDC-Centers for Disease Control and Prevention, CFU-colony forming units, TSA-tryptic soy agar, TSB-tryptic soy broth