Frank Oliver Henes
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Frank Oliver Henes has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
- Peter Bannas
Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
5 shared publications - Gerhard Adam
Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, 20246 Hamburg, Germany
4 shared publications - Kai-Jonathan Maas
Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
3 shared publications - Alexander Lenz
Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
2 shared publications - Clemens Spink
Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
2 shared publications Gerhard Adam
Department of Diagnostic and Interventional Radiology, Center for Radiology and Endoscopy, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246 Hamburg, Germany
2 shared publications
Latest Publications
- Open Access
- 11 November 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (11) , 2761
The Influence of Surgical Realignment Procedures on Dynamic Patellar Tracking: A Dynamic Magnetic Resonance Imaging-Controlled Feasibility Study
Persisting patellar maltracking following surgical realignment often remains unseen. The aim of this study was to analyze the effects of realignment procedures on patellofemoral kinematics in patients with patellofemoral instability (PFI) and patellofemoral maltracking (PM) by using dynamic magnetic resonance imaging (MRI). Patients planned for surgical patellar realignment due to PFI and a clinically and radiologically apparent PM between December 2019 and May 2022 were included. Patients without PM, limited range of motion, joint effusion, or concomitant injuries were excluded. Dynamic mediolateral translation (dMPT) and patella tilt (dPT) were measured preoperatively and three months postoperatively. In 24 patients (7 men, 17 women; mean age 23.0 years), 10 tibial tubercle transfers, 5 soft tissue patella tendon transfers, 6 trochleoplasties, 3 lateral lengthenings, 1 varizating distal femoral osteotomy (DFO), and 1 torsional DFO were performed. At final follow-up, dMPT (from 10.95 ± 5.93 mm to 4.89 ± 0.40 mm, p < 0.001) and dPT (from 14.50° ± 10.33° to 8.44° ± 7.46°, p = 0.026) were significantly improved. All static radiological parameters were corrected to physiological values. Surgical patellar realignment contributed to the significant improvement of patellofemoral kinematics, with an approximation to normal values. The postoperative application of dynamic MRI allowed for a quantification of the performed correction, allowing for a postoperative control of success.
- 11 November 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (11) , 2761
Open AccessThe Influence of Surgical Realignment Procedures on Dynamic Patellar Tracking: A Dynamic Magnetic Resonance Imaging-Controlled Feasibility Study
Persisting patellar maltracking following surgical realignment often remains unseen. The aim of this study was to analyze the effects of realignment procedures on patellofemoral kinematics in patients with patellofemoral instability (PFI) and patellofemoral maltracking (PM) by using dynamic magnetic resonance imaging (MRI). Patients planned for surgical patellar realignment due to PFI and a clinically and radiologically apparent PM between December 2019 and May 2022 were included. Patients without PM, limited range of motion, joint effusion, or concomitant injuries were excluded. Dynamic mediolateral translation (dMPT) and patella tilt (dPT) were measured preoperatively and three months postoperatively. In 24 patients (7 men, 17 women; mean age 23.0 years), 10 tibial tubercle transfers, 5 soft tissue patella tendon transfers, 6 trochleoplasties, 3 lateral lengthenings, 1 varizating distal femoral osteotomy (DFO), and 1 torsional DFO were performed. At final follow-up, dMPT (from 10.95 ± 5.93 mm to 4.89 ± 0.40 mm, p < 0.001) and dPT (from 14.50° ± 10.33° to 8.44° ± 7.46°, p = 0.026) were significantly improved. All static radiological parameters were corrected to physiological values. Surgical patellar realignment contributed to the significant improvement of patellofemoral kinematics, with an approximation to normal values. The postoperative application of dynamic MRI allowed for a quantification of the performed correction, allowing for a postoperative control of success.
- Open Access
Diagnostic Utility of Bronchoalveolar Lavage in Patients with Acute Leukemia under Broad-Spectrum Anti-Infective Treatment
Despite therapeutic advances in the prevention and treatment of febrile neutropenia, acute leukemia (AL) patients still have considerable febrile neutropenia-related mortality. However, the diagnostic yield of flexible bronchoscopy (FB) and bronchoalveolar lavage (BAL) in acute leukemia patients is unclear. In this retrospective single-center study, we analyzed 88 BAL samples of patients with acute leukemia and pulmonary infiltrates in spite of treatment with broad-spectrum anti-infective agents. The aim was to investigate the impact of FB with BAL on detecting causative organisms, which would result in a change in treatment regimens. The median age was 59 years, and 86% had acute myeloid leukemia. In 47%, pathogens were detectable in BAL fluid (pathogen bacteria, viruses, and fungi in 2, 15, and 18%, respectively), with Aspergillus fumigatus detected most frequently. BAL-guided anti-infective therapy changes were performed in 15%. The detection of herpes simplex and influenza viruses were the main reasons for treatment changes. Despite broad-spectrum anti-infective treatment, in approximately half of all patients, pathogens could still be isolated in BAL samples. However, consecutive changes in anti-infective treatment were considerably less frequent, with most changes performed in patients with Herpes simplex virus and Influenza A detection. The need for FB with BAL in patients with AL receiving broad-spectrum empiric anti-infective treatment should therefore be weighed carefully.
Open AccessDiagnostic Utility of Bronchoalveolar Lavage in Patients with Acute Leukemia under Broad-Spectrum Anti-Infective Treatment
Despite therapeutic advances in the prevention and treatment of febrile neutropenia, acute leukemia (AL) patients still have considerable febrile neutropenia-related mortality. However, the diagnostic yield of flexible bronchoscopy (FB) and bronchoalveolar lavage (BAL) in acute leukemia patients is unclear. In this retrospective single-center study, we analyzed 88 BAL samples of patients with acute leukemia and pulmonary infiltrates in spite of treatment with broad-spectrum anti-infective agents. The aim was to investigate the impact of FB with BAL on detecting causative organisms, which would result in a change in treatment regimens. The median age was 59 years, and 86% had acute myeloid leukemia. In 47%, pathogens were detectable in BAL fluid (pathogen bacteria, viruses, and fungi in 2, 15, and 18%, respectively), with Aspergillus fumigatus detected most frequently. BAL-guided anti-infective therapy changes were performed in 15%. The detection of herpes simplex and influenza viruses were the main reasons for treatment changes. Despite broad-spectrum anti-infective treatment, in approximately half of all patients, pathogens could still be isolated in BAL samples. However, consecutive changes in anti-infective treatment were considerably less frequent, with most changes performed in patients with Herpes simplex virus and Influenza A detection. The need for FB with BAL in patients with AL receiving broad-spectrum empiric anti-infective treatment should therefore be weighed carefully.
- 1 February 2021
- Published by Elsevier in European Journal of Radiology
- Vol. 135, 109491
Magnetic resonance imaging of midtarsal sprain: Prevalence and impact on the time of return to play in professional soccer players
- 1 February 2021
- Published by Elsevier in European Journal of Radiology
- Vol. 135, 109491
Magnetic resonance imaging of midtarsal sprain: Prevalence and impact on the time of return to play in professional soccer players
- Open Access
- 20 April 2020
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 36 (8) , 1533-1542
Reliability of non-contrast magnetic resonance angiography-derived aortic diameters in Marfan patients: comparison of inner vs. outer vessel wall measurements
Aortic diameter measurements play a crucial role for the indication of aortic root surgery in Marfan patients. However, for magnetic resonance angiography (MRA)-derived measurements, there is no consensus on whether the aortic wall should be included or excluded in the aortic diameter. The purpose of this retrospective study was to compare the reliability of non-contrast bright blood MRA aortic inner-to-inner and outer-to-outer edge measurements in patients with Marfan syndrome. Forty Marfan patients underwent ECG-gated balanced steady-state free-precession MRA of the aorta at 1.5 T. Two readers independently performed inner and outer measurements at different aortic levels. They rated the image quality of the delineation of both inner and outer vessel wall edges on a four-point scale. MRA-derived diameters of the sinuses of Valsalva were compared with echocardiography-derived diameters. Aortic vessel wall delineation score was rated higher at all levels for inner than for outer vessel walls (p < 0.001). Inter- and intraobserver variances of aortic measurements were smaller for inner-to-inner measurements at the sinuses of Valsalva, sinotubular junction and ascending aorta (p < 0.03). There was a difference of 1.1 ± 2.3 mm for inner MRA measurements (p = 0.014) and 6.9 ± 3.1 mm for outer MRA measurements (p < 0.001) when compared to echocardiographic leading-edge measurements. Inner-to-inner vessel wall diameter measurements in non-contrast bright blood MRA provide more reliable diameters when compared to outer-to-outer vessel wall measurements of the aortic root. Therefore, we propose to rely on inner rather than outer aortic wall measurements in non-contrast-MRA when monitoring aortic diameters in patients with Marfan syndrome.
- 20 April 2020
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 36 (8) , 1533-1542
Open AccessReliability of non-contrast magnetic resonance angiography-derived aortic diameters in Marfan patients: comparison of inner vs. outer vessel wall measurements
Aortic diameter measurements play a crucial role for the indication of aortic root surgery in Marfan patients. However, for magnetic resonance angiography (MRA)-derived measurements, there is no consensus on whether the aortic wall should be included or excluded in the aortic diameter. The purpose of this retrospective study was to compare the reliability of non-contrast bright blood MRA aortic inner-to-inner and outer-to-outer edge measurements in patients with Marfan syndrome. Forty Marfan patients underwent ECG-gated balanced steady-state free-precession MRA of the aorta at 1.5 T. Two readers independently performed inner and outer measurements at different aortic levels. They rated the image quality of the delineation of both inner and outer vessel wall edges on a four-point scale. MRA-derived diameters of the sinuses of Valsalva were compared with echocardiography-derived diameters. Aortic vessel wall delineation score was rated higher at all levels for inner than for outer vessel walls (p < 0.001). Inter- and intraobserver variances of aortic measurements were smaller for inner-to-inner measurements at the sinuses of Valsalva, sinotubular junction and ascending aorta (p < 0.03). There was a difference of 1.1 ± 2.3 mm for inner MRA measurements (p = 0.014) and 6.9 ± 3.1 mm for outer MRA measurements (p < 0.001) when compared to echocardiographic leading-edge measurements. Inner-to-inner vessel wall diameter measurements in non-contrast bright blood MRA provide more reliable diameters when compared to outer-to-outer vessel wall measurements of the aortic root. Therefore, we propose to rely on inner rather than outer aortic wall measurements in non-contrast-MRA when monitoring aortic diameters in patients with Marfan syndrome.
- Open Access
- 1 December 2016
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 19 (1) , 82
Non-contrast MR angiography at 1.5 Tesla for aortic monitoring in Marfan patients after aortic root surgery
- 1 December 2016
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 19 (1) , 82
Open AccessNon-contrast MR angiography at 1.5 Tesla for aortic monitoring in Marfan patients after aortic root surgery
- 21 October 2013
- Published by Elsevier in European Journal of Radiology
- Vol. 83 (1) , 167-172
Detection of occult vertebral fractures by quantitative assessment of bone marrow attenuation values at MDCT
- 21 October 2013
- Published by Elsevier in European Journal of Radiology
- Vol. 83 (1) , 167-172
Detection of occult vertebral fractures by quantitative assessment of bone marrow attenuation values at MDCT
- 24 February 2012
- Published by Elsevier in Academic Radiology
- Vol. 19 (6) , 718-722
A New Formula for Rapid Assessment of Pericardial Effusion Volume by Computed Tomography
- 24 February 2012
- Published by Elsevier in Academic Radiology
- Vol. 19 (6) , 718-722
A New Formula for Rapid Assessment of Pericardial Effusion Volume by Computed Tomography