Marion Wienecke
Research Subjects
Research Interests
Marion Wienecke has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Krzysztof Rokosz
Faculty of Electronics and Computer Science, Koszalin University of Technology, Sniadeckich 2, 75-453 Koszalin, Poland
3 shared publications - Jan Heeg
Institute of Surface and Thin Film Technology, Hochschule Wismar, Philipp-Mueller-Strasse 14, 23966 Wismar, Germany
2 shared publications - Andreas Lampka
Institute of Surface and Thin Film Technology, Hochschule Wismar, PF 1210, 23952 Wismar, Germany
1 shared publication - Antonia Haag
Department of Urology, Rostock University Medical Center, Schillingallee 35, 18057 Rostock, Germany
1 shared publication - Armin Springer
Department Life, Light & Matter, University of Rostock, Rostock, Germany
1 shared publication - Christoph Mewes
Institute of Surface and Thin Film Technology, Hochschule Wismar, PF 1210, 23952 Wismar, Germany
1 shared publication
Latest Publications
- Open Access
Interactive Effects of Copper-Doped Urological Implants with Tissue in the Urinary Tract for the Inhibition of Cell Adhesion and Encrustation in the Animal Model Rat
The insertion of a ureteral stent provides acute care by restoring urine flow and alleviating urinary retention or dysfunction. The problems of encrustation, bacterial colonization and biofilm formation become increasingly important when ureteral stents are left in place for a longer period of time. One way to reduce encrustation and bacterial adherence is to modify the stent surface with a diamond-like carbon coating, in combination with copper doping. The biocompatibilities of the Elastollan® base material and the a-C:H/Cu-mulitilayer coating were tested in synthetic urine. The copper content in bladder tissue was determined by atomic absorption spectroscopy and in blood and in urine by inductively coupled plasma mass spectrometry. Encrustations on the materials were analyzed by scanning electron microscopy, energy dispersive X-ray spectroscopy and Fourier transform infrared spectroscopy. A therapeutic window for copper ions of 0.5–1.0 mM was determined to kill bacteria without affecting human urothelial cells. In the rat animal model, it was found that copper release did not reach toxic concentrations in the affecting tissue of the urinary tract or in the blood. The encrustation behavior of the surfaces showed that the roughness of the amorphous carbon layer with the copper doping is probably the causal factor for the higher encrustation.
Open AccessInteractive Effects of Copper-Doped Urological Implants with Tissue in the Urinary Tract for the Inhibition of Cell Adhesion and Encrustation in the Animal Model Rat
The insertion of a ureteral stent provides acute care by restoring urine flow and alleviating urinary retention or dysfunction. The problems of encrustation, bacterial colonization and biofilm formation become increasingly important when ureteral stents are left in place for a longer period of time. One way to reduce encrustation and bacterial adherence is to modify the stent surface with a diamond-like carbon coating, in combination with copper doping. The biocompatibilities of the Elastollan® base material and the a-C:H/Cu-mulitilayer coating were tested in synthetic urine. The copper content in bladder tissue was determined by atomic absorption spectroscopy and in blood and in urine by inductively coupled plasma mass spectrometry. Encrustations on the materials were analyzed by scanning electron microscopy, energy dispersive X-ray spectroscopy and Fourier transform infrared spectroscopy. A therapeutic window for copper ions of 0.5–1.0 mM was determined to kill bacteria without affecting human urothelial cells. In the rat animal model, it was found that copper release did not reach toxic concentrations in the affecting tissue of the urinary tract or in the blood. The encrustation behavior of the surfaces showed that the roughness of the amorphous carbon layer with the copper doping is probably the causal factor for the higher encrustation.
- Open Access
Surface Characterization and Copper Release of a-C:H:Cu Coatings for Medical Applications
This paper focuses on the surface properties of a-C:H:Cu composite coatings for medical devices and how the release of Cu2+ ions from such coatings can be controlled. The released Cu ions have the potential to act as a bactericidal agent and inhibit bacterial colonization. A PVD–PECVD hybrid process was used to deposit a-C:H:Cu composite coatings onto Ti6Al4V substrates. We examine the layer surface properties using atomic force microscopy and static contact angle measurements. An increasing surface roughness and increasing contact angle of Ringer’s solution was measured with increasing copper mole fraction (XCu) in the coatings. The contact angle decreased when a supplementary bias voltage of −50 V was used during the a-C:H:Cu deposition. These findings are in line with earlier published results regarding these types of coatings. The release of Cu2+ ions from a-C:H:Cu coatings in Ringer’s solution was measured by anodic stripping voltammetry. Different layer structures were examined to control the time-resolved Cu release. It was found that the Cu release depends on the overall XCu in the a-C:H:Cu coatings and that an additional a-C:H barrier layer on top of the a-C:H:Cu layer effectively delays the release of Cu ions.
Open AccessSurface Characterization and Copper Release of a-C:H:Cu Coatings for Medical Applications
This paper focuses on the surface properties of a-C:H:Cu composite coatings for medical devices and how the release of Cu2+ ions from such coatings can be controlled. The released Cu ions have the potential to act as a bactericidal agent and inhibit bacterial colonization. A PVD–PECVD hybrid process was used to deposit a-C:H:Cu composite coatings onto Ti6Al4V substrates. We examine the layer surface properties using atomic force microscopy and static contact angle measurements. An increasing surface roughness and increasing contact angle of Ringer’s solution was measured with increasing copper mole fraction (XCu) in the coatings. The contact angle decreased when a supplementary bias voltage of −50 V was used during the a-C:H:Cu deposition. These findings are in line with earlier published results regarding these types of coatings. The release of Cu2+ ions from a-C:H:Cu coatings in Ringer’s solution was measured by anodic stripping voltammetry. Different layer structures were examined to control the time-resolved Cu release. It was found that the Cu release depends on the overall XCu in the a-C:H:Cu coatings and that an additional a-C:H barrier layer on top of the a-C:H:Cu layer effectively delays the release of Cu ions.
- Open Access
- 13 October 2016
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- Vol. 90 (5-8) , 2293-2308
SEM-EDS-based analysis of the amorphous carbon-treated grinding wheel active surface after reciprocal internal cylindrical grinding of Titanium Grade 2® alloy
- 13 October 2016
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- Vol. 90 (5-8) , 2293-2308
Open AccessSEM-EDS-based analysis of the amorphous carbon-treated grinding wheel active surface after reciprocal internal cylindrical grinding of Titanium Grade 2® alloy
- Open Access
- 1 September 2016
- Published by Walter de Gruyter GmbH in Advances in Materials Science
- Vol. 16 (3) , 15-25
Energy-Dispersive X-Ray Spectroscopy Mapping of Porous Coatings Obtained on Titanium by Plasma Electrolytic Oxidation in a Solution Containing Concentrated Phosphoric Acid with Copper Nitrate
- 1 September 2016
- Published by Walter de Gruyter GmbH in Advances in Materials Science
- Vol. 16 (3) , 15-25
Open AccessEnergy-Dispersive X-Ray Spectroscopy Mapping of Porous Coatings Obtained on Titanium by Plasma Electrolytic Oxidation in a Solution Containing Concentrated Phosphoric Acid with Copper Nitrate
- Open Access
The Effect of Bias Voltage and Gas Pressure on the Structure, Adhesion and Wear Behavior of Diamond Like Carbon (DLC) Coatings With Si Interlayers
In this study diamond like carbon (DLC) coatings with Si interlayers were deposited on 316L stainless steel with varying gas pressure and substrate bias voltage using plasma enhanced chemical vapor deposition (PECVD) technology. Coating and interlayer thickness values were determined using X-ray photoelectron spectroscopy (XPS) which also revealed the presence of a gradient layer at the coating substrate interface. Coatings were evaluated in terms of the hardness, elastic modulus, wear behavior and adhesion. Deposition rate generally increased with increasing bias voltage and increasing gas pressure. At low working gas pressures, hardness and modulus of elasticity increased with increasing bias voltage. Reduced hardness and modulus of elasticity were observed at higher gas pressures. Increased adhesion was generally observed at lower bias voltages and higher gas pressures. All DLC coatings significantly improved the overall wear resistance of the base material. Lower wear rates were observed for coatings deposited with lower bias voltages. For coatings that showed wear tracks considerably deeper than the coating thickness but without spallation, the wear behavior was largely attributed to deformation of both the coating and substrate with some cracks at the wear track edges. This suggests that coatings deposited under certain conditions can exhibit ultra high flexible properties.
Open AccessThe Effect of Bias Voltage and Gas Pressure on the Structure, Adhesion and Wear Behavior of Diamond Like Carbon (DLC) Coatings With Si Interlayers
In this study diamond like carbon (DLC) coatings with Si interlayers were deposited on 316L stainless steel with varying gas pressure and substrate bias voltage using plasma enhanced chemical vapor deposition (PECVD) technology. Coating and interlayer thickness values were determined using X-ray photoelectron spectroscopy (XPS) which also revealed the presence of a gradient layer at the coating substrate interface. Coatings were evaluated in terms of the hardness, elastic modulus, wear behavior and adhesion. Deposition rate generally increased with increasing bias voltage and increasing gas pressure. At low working gas pressures, hardness and modulus of elasticity increased with increasing bias voltage. Reduced hardness and modulus of elasticity were observed at higher gas pressures. Increased adhesion was generally observed at lower bias voltages and higher gas pressures. All DLC coatings significantly improved the overall wear resistance of the base material. Lower wear rates were observed for coatings deposited with lower bias voltages. For coatings that showed wear tracks considerably deeper than the coating thickness but without spallation, the wear behavior was largely attributed to deformation of both the coating and substrate with some cracks at the wear track edges. This suggests that coatings deposited under certain conditions can exhibit ultra high flexible properties.